Reticuloendothelial Contrast AgentsInfoSheet: - Contrast Agents - 
Intro, Overview, 
Characteristics, 
Types of, 
etc.MRI Resource Directory:
 - Contrast Agents -
 
Liver imaging with gadolinium contrast enhanced MRI is sometimes not sufficient for a reliable diagnosis of liver lesions. For this reasons, special liver Contrast agents that are targeted to the reticuloendothelial system (RES), have been developed to improve both detection and characterization of liver and spleen lesions. Reticuloendothelial Contrast Agents, as e.g. superparamagnetic iron oxides (SPIO), are taken up by healthy liver tissue but not tumors.
These RES targeted contrast agents provide a prolonged imaging window and enough time for high spatial resolution or multiple breath hold images. Reticuloendothelial contrast agents have an increased sensitivity for the detection of small liver lesions (e.g., metastases), compared with gadolinium enhanced MRI and spiral CT. At higher field strengths with an increased signal to noise ratio the susceptibility effect with iron oxide particles may be enhanced.
Other new agents (Gadobenate Dimeglumine, Gadoxetic Acid) have both an initial extracellular circulation and a delayed liver-specific uptake. Since a considerable part of these contrast agents is excreted in the bile, functional biliary imaging can diagnose biliary anomalies, postoperative bile leaks, and anastomotic strictures. Other agents, such as liposomes (with encapsulated Gd-DTPA) or DOTA complexes are in different development stages.

See also Hepatobiliary Contrast Agents, Gadolinium Oxide, Superparamagnetic Iron Oxide and Liposomes.
spacer
MRI Resources 
MRI Technician and Technologist Career - Spine MRI - Nerve Stimulator - Case Studies - Open Directory Project - Homepages
 
Magnevist®InfoSheet: - Contrast Agents - 
Intro, Overview, 
Characteristics, 
Types of, 
etc.MRI Resource Directory:
 - Contrast Agents -
 
Magnevist® is a paramagnetic ionic contrast agent for use in magnetic resonance imaging. Contrast enhanced MRI with Magnevist® allows additional diagnostic information of tumors, inflammation and vascular lesions and the determination or differentiation of such lesions.
The contrast enhancing effect is produced by the di-N-methylglucamine salt of gadopentetate (Gd-DTPA), the gadolinium complex of diethylenetriamine pentaacetic acid. Magnevist® has the strongest effect on T1 weighted images, by increasing T1 signal intensity in tissues where Magnevist® has accumulated.

WARNING: NEPHROGENIC SYSTEMIC FIBROSIS Gadolinium-based contrast agents increase the risk for nephrogenic systemic fibrosis (NSF) in patients with acute or chronic severe renal insufficiency (glomerular filtration rate less than 30 mL/min/1.73m2), or acute renal insufficiency of any severity due to the hepato-renal syndrome or in the perioperative liver transplantation period.

See also Ionic Intravenous Contrast Agents and Gadopentetate Dimeglumine.
Drug Information and Specification
CENTRAL MOIETY
Gd3+
CONTRAST EFFECT
T1, Predominantly positive enhancement
r1=3.4, r2=3.8, B0=1.0T
PHARMACOKINETIC
Intravascular, extracellular, renal excretion
1960 mosm/kgH2O
CONCENTRATION
0.5 mol/L
DOSAGE
0.1-0.3 mmol/kg / 0.2-0.6 mL/kg
PREPARATION
Finished product
INDICATION
Neuro/whole body
DEVELOPMENT STAGE
For sale
DISTRIBUTOR
See below
PRESENTATION
Vials of 5, 10, 15, 20 and 100 mL bulk package
Pre-filled syringes of 10, 15 and 20 mL
DO NOT RELY ON THE INFORMATION PROVIDED HERE, THEY ARE
NOT A SUBSTITUTE FOR THE ACCOMPANYING PACKAGE INSERT!
Distribution Information
TERRITORY
TRADE NAME
DEVELOPMENT
STAGE
DISTRIBUTOR
USA, Canada
Magnevist®
for sale
Asia
Magnevist®
for sale
EU
Magnevist®
suspended
Turkey
Magnevist®, Magnograf
for sale
Australia
Magnevist®
for sale
spacer

• View the DATABASE results for 'Magnevist®' (7).Open this link in a new window

 
Further Reading:
  Basics:
Magnevist Prescription Drug Discount Sources
   by www.institutedc.org    
Important Drug Warning for Gadolinium-Based Contrast Agents
Wednesday, 12 September 2007   by www.ismrm.org    
MAGNEVIST ® (brand of gadopentetate dimeglumine) Injection - WARNING: NEPHROGENIC SYSTEMIC FIBROSIS
May 2009   by berlex.bayerhealthcare.com    
Magnevist Package Insert
2000
  News & More:
EMA's final opinion confirms restrictions on use of linear gadolinium agents in body scans
Friday, 21 July 2017   by www.ema.europa.eu    
Gadolinium-containing contrast agents: removal of Omniscan and iv Magnevist, restrictions to the use of other linear agents
Friday, 5 January 2018   by www.gov.uk    
FDA Drug Safety Communication: FDA warns that gadolinium-based contrast agents (GBCAs) are retained in the body; requires new class warnings
Tuesday, 19 December 2017   by www.fda.gov    
Spurious Hypocalcemia After Omniscan- or OptiMARK-Enhanced Magnetic Resonance Imaging: An Algorithm for Minimizing a False-Positive Laboratory Value
October 2004   by www.findarticles.com    
MRI Resources 
Collections - MRI Technician and Technologist Schools - Contrast Enhanced MRI - Libraries - Diffusion Weighted Imaging - General
 
Intra Uterine PessarMRI Resource Directory:
 - Safety -
 
Most of the commonly used intrauterine contraceptive devices (IUD) do not move under the influence of the magnetic field, do not heat up during sequences usually applied for pelvic imaging, and do not produce major artifacts in vitro or in vivo.
mri safety guidance
MRI Safety Guidance
Thus, patients with either all plastic or copper IUDs can be safely imaged with magnetic resonance imaging (MRI) machines.
spacer
MRI Resources 
Online Books - Journals - Absorption and Emission - Image Quality - Liver Imaging - Nerve Stimulator
 
Omniscan®InfoSheet: - Contrast Agents - 
Intro, Overview, 
Characteristics, 
Types of, 
etc.MRI Resource Directory:
 - Contrast Agents -
 
Omniscan® is a nonionic chelate complex with low osmolality used as a paramagnetic MRI contrast agent. The efficacy of Omniscan® is similar to that of Gd-DTPA. Omniscan® is given intravenously to enhance images of intracranial and spinal lesions where there is abnormal vascularity or an abnormal blood brain barrier. The complex does not cross an intact blood brain barrier so Omniscan® only accumulates in lesions such as neoplasm's and abscesses.

WARNING: NEPHROGENIC SYSTEMIC FIBROSIS Gadolinium-based contrast agents increase the risk for nephrogenic systemic fibrosis (NSF) in patients with acute or chronic severe renal insufficiency (glomerular filtration rate less than 30 mL/min/1.73m2), or acute renal insufficiency of any severity due to the hepato-renal syndrome or in the perioperative liver transplantation period.

See also Gadodiamide, and Classifications, Characteristics, etc.
Drug Information and Specification
NAME OF COMPOUND
Gadodiamide, Gd-DTPA-BMA
CENTRAL MOIETY
Gd2+
CONTRAST EFFECT
T1, Predominantly positive enhancement
r1=3.9, r2=4.3, B0=1.0T
PHARMACOKINETIC
Intravascular, extracellular, renal excretion
798 mosm/kgH2O
CONCENTRATION
287 mg/mL,0.5 mol/L
DOSAGE
0.1-0.2 mmol/kg / 0.2-0.4 ml/kg
PREPARATION
Finished product
INDICATION
Neuro/whole body
DEVELOPMENT STAGE
For sale
DISTRIBUTOR
See below
PRESENTATION
Vials of 10 mL, 15 mL and 20 mL
DO NOT RELY ON THE INFORMATION PROVIDED HERE, THEY ARE
NOT A SUBSTITUTE FOR THE ACCOMPANYING PACKAGE INSERT!
Distribution Information
TERRITORY
TRADE NAME
DEVELOPMENT
STAGE
DISTRIBUTOR
USA
Omniscan®
for sale
EU
Omniscan®
suspended
Australia
Omniscan®
for sale
spacer

• View the DATABASE results for 'Omniscan®' (7).Open this link in a new window

 
Further Reading:
  Basics:
Important Drug Warning for Gadolinium-Based Contrast Agents
Wednesday, 12 September 2007   by www.ismrm.org    
Omniscan Pharmacokinetics
  News & More:
Gadolinium-containing contrast agents: removal of Omniscan and iv Magnevist, restrictions to the use of other linear agents
Friday, 5 January 2018   by www.gov.uk    
Spurious Hypocalcemia After Omniscan- or OptiMARK-Enhanced Magnetic Resonance Imaging: An Algorithm for Minimizing a False-Positive Laboratory Value
October 2004   by www.findarticles.com    
MRI Resources 
MRA - Journals - Breast MRI - MR Guided Interventions - Education pool - Jobs pool
 
Gadopentetate DimeglumineInfoSheet: - Contrast Agents - 
Intro, Overview, 
Characteristics, 
Types of, 
etc.MRI Resource Directory:
 - Contrast Agents -
 
Short name: Gd-DTPA, generic name: Gadopentetate dimeglumine, chemical compound: Gadolinium-diethylenetriaminepentaacetic acid
Gadopentetate dimeglumine was introduced in 1981, as the first paramagnetic MRI contrast agent (ionic). The Gd-induced dipole dipole interactions lead to shortening of T1, which results in contrast enhancement on T1 weighted images. The used metal ion Gd3+ (gadolinium) is toxic, and therefore bound in the renally excreted DTPA chelate, a very stable complex. The Gd-complex also induce susceptibility effects, as a result of the magnetic field gradient between the contrast agent in the blood vessels and the surrounding tissue, that lead to shortening of T2 or T2*.
Following intravenous administration, the compound is distributed rapidly in the extracellular space and is eliminated unchanged by glomerular filtration via the kidneys. Up to 6 hours, post injection an average of 83% of the dose is eliminated renal.

See also Magnevist®, Gadolinium and Contrast Agents.
spacer

• View the DATABASE results for 'Gadopentetate Dimeglumine' (5).Open this link in a new window

 
Further Reading:
  Basics:
Magnevist Package Insert
2000
Gadopentetic acid
   by en.wikipedia.org    
  News & More:
EMA's final opinion confirms restrictions on use of linear gadolinium agents in body scans
Friday, 21 July 2017   by www.ema.europa.eu    
MRI Resources 
Brain MRI - Image Quality - IR - Patient Information - Colonography - Equipment
 
previous      11 - 15 (of 16)     next
Result Pages : [1]  [2 3 4]
 Random Page
 
Share This Page
FacebookTwitterLinkedIn

MR-TIP    
Community   
User
Pass
Forgot your UserID/Password ?    



Next big thing in MRI will be :
AI 
remote operator 
personalized protocols 
helium-free 
molecular MRI 
portable MRI 

Look
      Ups





MR-TIP.com uses cookies! By browsing MR-TIP.com, you agree to our use of cookies.

Magnetic Resonance - Technology Information Portal
Member of SoftWays' Medical Imaging Group - MR-TIP • Radiology-TIP • Medical-Ultrasound-Imaging • 
Copyright © 2003 - 2024 SoftWays. All rights reserved. [ 19 April 2024]
Terms of Use | Privacy Policy | Advertising
 [last update: 2024-02-26 03:41:00]