Chemical Shift Reference
 
A compound with respect to whose frequency the chemical shifts of other compounds can be compared. The standard can be either internal or external to the sample. Because of the need for possible corrections due to differential magnetic susceptibility between an external standard and the sample being measured, the use of an internal standard is generally preferred.
spacer
MRI Resources 
Jobs - Crystallography - Used and Refurbished MRI Equipment - Collections - Non-English - Movies
 
Contrast Enhanced FASTInfoSheet: - Sequences - 
Intro, 
Overview, 
Types of, 
etc.MRI Resource Directory:
 - Sequences -
 
(CE-FAST) In this technique, the MR signal is sampled immediately prior to each RF pulse. Because the signal is formed by a true spin echo, its contrast is predominantly T2-, rather than T2*-based and is less sensitive to artifacts and signal losses related to field non-uniformity and susceptibility variation. While the signal to noise ratio is limited, the CE-FAST method has the advantage of good contrast.

See Contrast Enhanced Gradient Echo Sequence and Gradient Echo Sequence.
spacer

• View the DATABASE results for 'Contrast Enhanced FAST' (5).Open this link in a new window

MRI Resources 
Breast Implant - Directories - Blood Flow Imaging - Lung Imaging - Universities - Safety Products
 
Contrast Enhanced Gradient Echo SequenceInfoSheet: - Sequences - 
Intro, 
Overview, 
Types of, 
etc.
 
Contrast enhanced GRE sequences provide T2 contrast but have a relatively poor SNR. Repetitive RF pulses with small flip angles together with appropriate gradient profiles lead to the superposition of two resonance signals.
The first signal is due to the free induction decay FID observed after the first and all ensuing RF excitations.
The second is a resonance signal obtained as a result of a spin echo generated by the second and all addicted RF-pulses.
Hence it is absent after the first excitation, it is a result of the free induction decay of the second to last RF-excitation and has a TE, which is almost 2TR. For this echo to occur the gradients have to be completely symmetrical relative to the half time between two RF-pulses, a condition that makes it difficult to integrate this pulse sequence into a multiple slice imaging technique. The second signal not only contains echo contributions from free induction decay, but obviously weakened by T2-decay. Since the echo is generated by a RF-pulse, it is truly T2 rather than T2* weighted. Correspondingly it is also less sensitive to susceptibility changes and field inhomogeneities.
Companies use different acronyms to describe certain techniques.
Different terms (see also acronyms) for these gradient echo pulse sequences:
CE-FAST Contrast Enhanced Fourier Acquired Steady State,
CE-FFE Contrast Enhanced Fast Field Echo,
CE-GRE Contrast Enhanced Gradient-Echo,
DE-FGR Driven Equilibrium FGR,
FADE FASE Acquisition Double Echo,
PSIF Reverse Fast Imaging with Steady State Precession,
SSFP Steady State Free Precession,
T2 FFE Contrast Enhanced Fast Field Echo (T2 weighted).

In this context, 'contrast enhanced' refers to the pulse sequence, it does not mean enhancement with a contrast agent.
spacer

• View the DATABASE results for 'Contrast Enhanced Gradient Echo Sequence' (4).Open this link in a new window

Searchterm 'Susceptibility' was also found in the following services: 
spacer
News  (3)  Resources  (1)  Forum  (6)  
 
Dephasing
 
The spins (protons) go out of phase in the transverse plane when the Rf pulse is switched of. This dephasing is due to static magnetic field inhomogeneities intrinsic (i.e. susceptibility changes at tissue interfaces) and extrinsic (i.e. field inhomogeneities of the main magnetic field) to the examined object.

See also T2*.
spacer

• View the DATABASE results for 'Dephasing' (26).Open this link in a new window

 
Further Reading:
  Basics:
Spin echoes, CPMG and T2 relaxation - Introductory NMR & MRI from Magritek
2013   by www.azom.com    
Comparison of Fast Spin-Echo Versus Conventional Spin-Echo MRI forEvaluating Meniscal Tears
June 2005   by www.ajronline.org    
Contrast mechanisms in magnetic resonance imaging
2004   by www.iop.org    
MRI Resources 
Education - Cardiovascular Imaging - MR Myelography - Claustrophobia - Guidance - Nerve Stimulator
 
Diamagnetism
 
Diamagnetism is a form of magnetism that is only exhibited by a substance in the presence of an externally applied magnetic field. It is the result of changes in the orbital motion of electrons due to the application of an externally applied magnetic field. Applying a magnetic field causes a momentary electromotive force (a consequence of Faraday's law), which modifies the electronic orbitals of atoms/molecules in a substance in such a way, that the orbitals produce an induced magnetic field, which opposes the applied field (a consequence of Lenz's law). However, the induced magnetic moment is very small in most everyday materials.
Diamagnets are repelled by magnetic fields. However, since diamagnetism is such a weak property its effects are not observable in every-day life.
However, in Magnetic Resonance Imaging for example barium sulfate suspensions lead with its weak negative magnetic susceptibility to a decrease in signal.

See also magnetism, ferromagnetism, paramagnetism, and superparamagnetism.
spacer

• View the DATABASE results for 'Diamagnetism' (7).Open this link in a new window

 
Further Reading:
  Basics:
Magnet basics
   by my.execpc.com    
Diamagnetism
   by en.wikipedia.org    
MRI Resources 
IR - Safety Products - Anatomy - Open Directory Project - Absorption and Emission - Blood Flow Imaging
 
previous      16 - 20 (of 46)     next
Result Pages : [1]  [2 3 4 5 6 7 8 9 10]
 Random Page
 
Share This Page
FacebookTwitterLinkedIn

MR-TIP    
Community   
User
Pass
Forgot your UserID/Password ?    



How AI will impact MRI :
only diagnostics 
saving time 
reducing cost 
makes planning obsolete 
reduce human knowledge 
not at all 

Look
      Ups





MR-TIP.com uses cookies! By browsing MR-TIP.com, you agree to our use of cookies.

Magnetic Resonance - Technology Information Portal
Member of SoftWays' Medical Imaging Group - MR-TIP • Radiology-TIP • Medical-Ultrasound-Imaging • 
Copyright © 2003 - 2024 SoftWays. All rights reserved. [ 28 March 2024]
Terms of Use | Privacy Policy | Advertising
 [last update: 2024-02-26 03:41:00]