Result : Searchterm 'Superparamagnetic Iron Oxide' found in 3 terms [] and 30 definitions []
previous     21 - 25 (of 33)     next
Result Pages : [1]  [2 3 4 5 6 7]
MRI Resources 
Equipment - Homepages - Raman Spectroscopy - PACS - Research Labs - Spectroscopy pool
 
Feridex°InfoSheet: - Contrast Agents - 
Intro, Overview, 
Characteristics, 
Types of, 
etc.MRI Resource Directory:
 - Contrast Agents -
 
A brand name for ferumoxide (same as Endoremâ„¢)
Feridex® is a sterile aqueous colloid of superparamagnetic iron oxide associated with dextran for intravenous administration as a MRI contrast medium for the detection of liver lesions that are associated with an alteration in the RES.
Feridex® is taken up by macrophages, found only in healthy liver cells but not in most tumors. Tissues such as metastases, primary liver cancer, cysts and various benign tumors, adenomas and hyperplasia retain their native signal intensity, so the contrast between normal and abnormal tissue is increased. Feridex® is a black to reddish-brown aqueous colloid.
See also Ferumoxide.

In November 2008, AMAG Pharmaceuticals, Inc. decided to discontinue the manufacturing of Feridex.
Drug Information and Specification
NAME OF COMPOUND
Dextran-coated ferumoxide, Ami-25
CENTRAL MOIETY
Fe2+/Fe3+
CONTRAST EFFECT
T2, predominantly negative enhancement
r1=40.0, r2=160, B0=0.47T
PHARMACOKINETIC
RES-directed
340 mosm/kgH2O
CONCENTRATION
11.2mg Fe/ml
DOSAGE
15 µmol Fe/kg
PREPARATION
Suspend in an isotonic glucose solution
INDICATION
DEVELOPMENT STAGE
For sale
DISTRIBUTOR
See below
PRESENTATION
Ampoule of 8 mL
DO NOT RELY ON THE INFORMATION PROVIDED HERE, THEY ARE
NOT A SUBSTITUTE FOR THE ACCOMPANYING PACKAGE INSERT!
Distribution Information
TERRITORY
TRADE NAME
DEVELOPMENT
STAGE
DISTRIBUTOR
USA
-
-
EU
Brazil
for sale ?
Argentina
for sale ?
South Korea
for sale ?
Israel
for sale ?
spacer
 
Further Reading:
  Basics:
AMAG Pharmaceuticals Inc. Q4 2008 Earnings Call Transcript
Friday, 27 February 2009   by seekingalpha.com    
Feridex Prescribing Information(.pdf)
   by berlex.bayerhealthcare.com    
  News & More:
MAGNETIC RESONANCE IMAGING OF FOCAL LIVER LESIONS(.pdf)
2002
MRI Resources 
Cardiovascular Imaging - Stent - Lung Imaging - Spectroscopy pool - Stimulator pool - Education
 
FerrioxamineInfoSheet: - Contrast Agents - 
Intro, Overview, 
Characteristics, 
Types of, 
etc.
 
Ferrioxamines are potential iron oxide-based intravascular contrast agents. Ferrioxamine methanesulfonate, ferrioxamine-B, and hydroxyethyl-starch-ferrioxamine have been tested as MRI contrast agents, partly in clinical trials.
Ferrioxamine methanesulfonate was tested as a paramagnetic agent for the imaging of the kidney and the urogenital system. Hydroxyethyl-starch-ferrioxamine has the potential to provide information regarding myocardial vascular flow and ferrioxamine-B derivatives may be used as hepatobiliary contrast agents.

See also Superparamagnetic Iron Oxide, Hepatobiliary Contrast Agents.
spacer

• View the DATABASE results for 'Ferrioxamine' (2).Open this link in a new window

MRI Resources 
Image Quality - Pathology - Service and Support - Pediatric and Fetal MRI - Jobs - Resources
 
GastroMARK®InfoSheet: - Contrast Agents - 
Intro, Overview, 
Characteristics, 
Types of, 
etc.MRI Resource Directory:
 - Contrast Agents -
 
GastroMARK® belongs to the negative oral contrast agents (same as Lumirem®, another brand name for ferumoxsil). GastroMARK® is used to distinguish the loops of the bowel from other abdominal structures and physiology. When GastroMARK® is ingested, it flows through and darkens the stomach and the small intestine in 30 to 45 minutes. By more clearly identifying the intestinal loops, GastroMARK® improves visualization of adjacent abdominal tissues such as the pancreas.
Drug Information and Specification
NAME OF COMPOUND
Ferumoxsil, silicone-coated superparamagnetic iron oxide, USAN, AMI-121
CENTRAL MOIETY
Fe3+/Fe2+
CONTRAST EFFECT
T2*enhanced
r1=3.4, r2=3.8, B0=1.0T
PHARMACOKINETIC
Gastrointestinal
OSMOLALITY
250 mosm/kgH2O
CONCENTRATION
52.5mg Fe/300mL
DOSAGE
300 mL oral
PREPARATION
Finished product
INDICATION
Bowel marking
DEVELOPMENT STAGE
For sale
DISTRIBUTOR
See below
PRESENTATION
Bottles containing 300 mL
DO NOT RELY ON THE INFORMATION PROVIDED HERE, THEY ARE
NOT A SUBSTITUTE FOR THE ACCOMPANYING PACKAGE INSERT!
Distribution Information
TERRITORY
TRADE NAME
DEVELOPMENT
STAGE
DISTRIBUTOR
USA
GastroMARK®
For sale
spacer

• View the DATABASE results for 'GastroMARK®' (6).Open this link in a new window

 
Further Reading:
  Basics:
ferumoxsil, oral suspension GastroMARK GastroMARK ®
MATERIAL SAFETY DATA SHEET
   by dailymed.nlm.nih.gov    
MRI Resources 
Musculoskeletal and Joint MRI - Raman Spectroscopy - MR Guided Interventions - Shoulder MRI - Research Labs - Safety Products
 
Gastrointestinal Paramagnetic Contrast AgentsInfoSheet: - Contrast Agents - 
Intro, Overview, 
Characteristics, 
Types of, 
etc.MRI Resource Directory:
 - Contrast Agents -
 
Paramagnetic substances, for example Gd-DTPA solutions, are used as MRI oral contrast agents in gastrointestinal imaging to depict the lumen of the digestive organs. Different Gd-DTPA solutions or zeolites containing gadolinium can be used e.g., for diagnosis of delayed gastric emptying, diagnosis of Crohn's disease etc.
Low concentrations of gastrointestinal paramagnetic contrast agents cause a reduction in T1 relaxation time; consequently, these agents act on T1 weighted images by increasing the signal intensity of the bowel lumen. High concentrations cause T2 shortening by decreasing the signal, similar to superparamagnetic iron oxide. Gd-DTPA chelates are unstable at the low pH in the stomach, therefore buffering is necessary for oral use.

See also Gadopentetate Gastrointestinal, Gadolinium Zeolite, Negative Oral Contrast Agents, Gastrointestinal Superparamagnetic Contrast Agents, and Ferric ammonium citrate.
 
Images, Movies, Sliders:
 MR Colonography Gadolinium per Rectum  Open this link in a new window
      

Courtesy of  Robert R. Edelman
 
spacer

• View the DATABASE results for 'Gastrointestinal Paramagnetic Contrast Agents' (5).Open this link in a new window

MRI Resources 
MRI Reimbursement - MRI Technician and Technologist Schools - Education pool - Health - Absorption and Emission - MRI Physics
 
Gastrointestinal Superparamagnetic Contrast AgentsInfoSheet: - Contrast Agents - 
Intro, Overview, 
Characteristics, 
Types of, 
etc.MRI Resource Directory:
 - Contrast Agents -
 
Gastrointestinal (GI) superparamagnetic contrast agents are used in MRI to improve the visualization of e.g., the intestinal tract, the pancreas (see MRCP), etc. Disadvantages are susceptibility artifacts e.g., dependent on delayed imaging or large volumes resulting in artifacts in the colon and distal small bowel loops related to higher concentration of the particles and absorption of the fluid.
Different types of MRI gastrointestinal superparamagnetic contrast agents:
•
Magnetite albumin microsphere

Usually gastrointestinal superparamagnetic contrast media consist of small iron oxide crystals (ferrites), which produce a signal reduction in the stomach and bowel after oral administration. The T2 shortening caused by these particles is produced from the local magnetic field inhomogeneities associated with the large magnetic moments of superparamagnetic particles. Ferrites are iron oxides of the general formula Fe203.MO, where M is a divalent metal ion and may be mixed with Fe3O4 in different preparations. Ferrites can produce symptoms of nausea after oral administration, as well as flatulence and a transient rise in serum iron. Embedding in inert substances reduce side effects by decreasing the absorption and interaction with body tissues. Combining these contrast materials with polymers such as polyethylene glycol or cellulose, or with sugars such as dextrose, results in improved T1 and/or T2 relaxivity compared with that of the contrast agent alone.

See also Negative Oral Contrast Agents, Gastrointestinal Diamagnetic Contrast Agents, Relaxivity, and Combination Oral Contrast Agents.
spacer

• View the DATABASE results for 'Gastrointestinal Superparamagnetic Contrast Agents' (6).Open this link in a new window

 
Further Reading:
  Basics:
Negative GI Contrast Agents
   by www.mritutor.org    
MRI Resources 
Calculation - Non-English - Open Directory Project - Collections - Image Quality - Breast Implant
 
previous      21 - 25 (of 33)     next
Result Pages : [1]  [2 3 4 5 6 7]
 Random Page
 
Share This Page
FacebookTwitterLinkedIn

MR-TIP    
Community   
User
Pass
Forgot your UserID/Password ?    



MRI is trending to low field magnets :
reduced costs will lead to this change 
AI will close the gap to high field 
only in remote areas 
is only temporary 
never 

Look
      Ups





MR-TIP.com uses cookies! By browsing MR-TIP.com, you agree to our use of cookies.

Magnetic Resonance - Technology Information Portal
Member of SoftWays' Medical Imaging Group - MR-TIP • Radiology-TIP • Medical-Ultrasound-Imaging • 
Copyright © 2003 - 2024 SoftWays. All rights reserved. [ 29 March 2024]
Terms of Use | Privacy Policy | Advertising
 [last update: 2024-02-26 03:41:00]