Clariscan™InfoSheet: - Contrast Agents - 
Intro, Overview, 
Characteristics, 
Types of, 
etc.MRI Resource Directory:
 - Contrast Agents -
 
Clariscan™ (gadoteric acid), a macrocyclic and ionic gadolinium-based contrast agent has newly been approved using the decentralized procedure with marketing authorization in place in Norway. It will be introduced by GE Healthcare to European countries in 2017.


See also: Paramagnetic Contrast Agents, Contrast Medium, Extracellular Fluid Agents, Ionic Intravenous Contrast Agents, Nonionic Intravenous Contrast Agents, Chelate, Adverse Reaction and Nephrogenic Systemic Fibrosis.

See also the related poll result: 'The development of contrast agents in MRI is'

Drug Information and Specification
NAME OF COMPOUND Gadoteric Acid
DEVELOPER GE Healthcare
CENTRAL MOIETY Gadolinium
CONTRAST EFFECT T1, Predominantly positive enhancement
RELAXIVITY R1 3.1, R2 3.6, B0 = 1.5 Tesla
PHARMACOKINETIC Intravascular, extracellular, renal excretion
OSMOLALITY 1350 mOsm.kg-1
CONCENTRATION 0.5 mmol /mL
DOSAGE 0.1 mmol/kg / 0.2 ml/kg
INDICATION Brain, spine and associated tissues
PRESENTATIONS Glass vial 5, 10, 15, 20 mL
Glass bottle 50, 100 mL
Polypropylene bottles 50, 100 mL
Plastic (Crystal Clear Polymer) pre-filled syringes 10, 15, 20 mL
DEVELOPMENT STAGE Sale starts 2017 in Norway, Sweden, UK. Global launch is planned.
DO NOT RELY ON THE INFORMATION PROVIDED HERE, THEY ARE NOT A SUBSTITUTE FOR THE ACCOMPANYING PACKAGE INSERT


[ Clariscan™ was also the name of an contrast agent under development by Amersham Health around the year 2000 which doesn't reach the market: '(An iron-based contrast agent with large molecular size, which prevents diffusion into body tissues and was developed for MR imaging of the liver (taken up by macrophages), tumor microvasculature and microvessel permeability. The blood half live of the particles with 11-20 nm diameter is 3-4 hours. See also NC100150 Injection and Ultrasmall Superparamagnetic Iron Oxide)'.
The new developed Clariscan™ by GE Healthcare is a totally different contrast agent.]
spacer
 
Further Reading:
  Basics:
SUMMARY OF PRODUCT CHARACTERISTICS
Wednesday, 22 February 2017   by www.mhra.gov.uk    
  News & More:
GE Healthcare expands MRI contrast media product range in Europe with launch of macrocyclic agent ClariscanTM
Wednesday, 1 March 2017   by www.businesswire.com    
MRI Resources 
Developers - MRI Technician and Technologist Career - Software - Collections - Lung Imaging - Implant and Prosthesis
 
Virgo™InfoSheet: - Devices -
Intro, 
Types of Magnets, 
Overview, 
etc.MRI Resource Directory:
 - Devices -
 
From Virgo
www.canamglobal.com/mri/virgomri.html This open C-shaped MRI system eases patient comfort and technologist maneuverability. The Virgo™ patient table is detachable and moves on easy rolling castors. Able to accommodate patient weights up to 160 kg, the tabletop has a range of motion of 30 cm in the lateral direction and 90cm in the longitudinal direction.
(Sorry, no picture available.)

Device Information and Specification
CLINICAL APPLICATION Whole body
CONFIGURATION C shaped
SURFACE COILS Head, Body, Neck, Knee, Shoulder, Spine, Wrist, Breast, Extremity, Lumbar Spine, TMJ
SPECTROSCOPY No
SYNCHRONIZATION Standard cardiac gating, ECG/peripheral, respiratory gating
PULSE SEQUENCES 2D Spin Echo (single and multi-echo), 2D Inversion Recovery, 2D Sequential and 3D Volume Gradient Echo, 2D and 3D Spoiled Gradient Echo
IMAGING MODES Localizer, single slice, multislice, volume, fast, POMP, multi slab, cine, slice and frequency zip, extended dynamic range, tailored RF
TR steps of 1 msec
TE steps of 1 msec
SINGLE/MULTI SLICE Simultaneous scan and reconstruction;; 100 images/second reconstruction
FOV 400 mm
SLICE THICKNESS 2D : 2 mm; 3D : 0.5 mm
MEASURING MATRIX 512x512
PIXEL INTENSITY 256 gray levels
MAGNET TYPE Permanent
BORE DIAMETER
or Vertical Gap
44 cm
FIELD STRENGTH 0.35 T
STRENGTH 15 mT/m
5-GAUSS FRINGE FIELD 3 m/3 m
SHIMMING Passive
spacer
MRI Resources 
General - MR Guided Interventions - Most Wanted - Breast MRI - Stent - Equipment
 
G-SCANInfoSheet: - Devices -
Intro, 
Types of Magnets, 
Overview, 
etc.MRI Resource Directory:
 - Devices -
 
www.esaote.de/04_kernspin/gscan/gscan.htm From Esaote S.p.A.; Esaote introduced the new G-SCAN at the RSNA in Dec. 2004. The G-SCAN covers almost all musculoskeletal applications including the spine. The tilting gantry is designed for scanning in weight-bearing positions. This unique MRI scanner is developed in line with the Esaote philosophy of creating high quality MRI systems that are easy to install and that have a low breakeven point.

Device Information and Specification (Under Development)
CLINICAL APPLICATION Musculoskeletal, extremity
CONFIGURATION Open MRI
SURFACE COILS Spine, extremity, shoulder, flex coil, knee dual phased array, ankle//foot dual phased array, hand//wrist dual phased array
PULSE SEQUENCES SE, GE, IR, STIR, TSE, 3D CE, GE-STIR, 3D GE, ME, TME, HSE
IMAGING MODES Single, multislice, volume study, fast scan, multi slab, cine
FOV 100 up to 350 mm, 25 mm displayed
DISPLAY MATRIX 512 x 512
MEASURING MATRIX 256 x 256 maximum
MAGNET TYPE Permanent
BORE DIAMETER
or W x H
33 cm H, open
POWER REQUIREMENTS 100/110/200/220/230/240
FIELD STRENGTH 0.25 T
STRENGTH 25 mT/m
5-GAUSS FRINGE FIELD, radial/axial 180 cm
SHIMMING Passive
spacer

• View the DATABASE results for 'G-SCAN' (3).Open this link in a new window

Searchterm 'Spine MRI' was also found in the following services: 
spacer
News  (17)  Resources  (7)  Forum  (4)  
 
S-SCANInfoSheet: - Devices -
Intro, 
Types of Magnets, 
Overview, 
etc.
 
www.esaote.com/products/MRI/sScan/products1.htm From Esaote S.p.A.; Esaote introduced the S-SCAN at RSNA in November 2007. The S-SCAN is a dedicated joint and spine MR scanner derived from the company's earlier G-SCAN system. Unlike the G-SCAN, neither the patient table nor the magnet can rotate from horizontal to vertical position. The patient table can only moved manually. Improved electronics, new coils for lumbar and cervical spine, new pulse sequences, a modified version of the magnet poles and gradient coils are used with a new software release in the S-SCAN.
Esaote North America is the exclusive U.S. distributor of this MRI device.
Device Information and Specification (Under Development)
CLINICAL APPLICATION Musculoskeletal, extremity
CONFIGURATION Open MRI
SURFACE COILS 4-channel phased array spine coil, extremity, shoulder, flex coil, knee dual phased array, ankle//foot dual phased array, hand//wrist dual phased array
PULSE SEQUENCES SE, GE, IR, STIR, TSE, 3D CE, GE-STIR, 3D GE, ME, TME, HSE
IMAGING MODES Single, multislice, volume study, fast scan, multi slab, cine
FOV 25 cm
DISPLAY MATRIX 512 x 512
MEASURING MATRIX 256 x 256 maximum
MAGNET TYPE Permanent
BORE DIAMETER
or W x H
33 cm H, open
POWER REQUIREMENTS 3 kW; 110/220 V single phase
FIELD STRENGTH 0.25 T
STRENGTH 25 mT/m
5-GAUSS FRINGE FIELD, radial/axial 180 cm
SHIMMING Passive
spacer

• View the DATABASE results for 'S-SCAN' (3).Open this link in a new window


• View the NEWS results for 'S-SCAN' (1).Open this link in a new window.
 
Further Reading:
  News & More:
Wichita medical facility gets first Hologic S-scan MRI in the United States
Friday, 19 October 2007   by wichita.bizjournals.com    
MRI Resources 
Used and Refurbished MRI Equipment - Crystallography - RIS - Portals - Shielding - Intraoperative MRI
 
Signa Profile™InfoSheet: - Devices -
Intro, 
Types of Magnets, 
Overview, 
etc.MRI Resource Directory:
 - Devices -
 
From GE Healthcare;
www.gehealthcare.com/usen/mr/profilei/index.html the New Signa Profile/i is a patient friendly open MRI system that virtually eliminates patient anxiety and claustrophobia, without compromising diagnostic utility.
Device Information and Specification
CLINICAL APPLICATION Whole body
CONFIGURATION Open MRI
SURFACE COILS Integrated transmit body coil, body flex sizes: M, L, XL, quadrature, head coil quadrature, 4 channel neurovascular array, 8 channel CTL array, quad. c-spine, 2 channel shoulder array, extremity coil, 3 channel wrist array, 4 channel breast array, 6, 9, 11 inch general purpose loop coils
SPECTROSCOPY No
SYNCHRONIZATION Standard cardiac gating, ECG/peripheral, respiratory gating
PULSE SEQUENCES Standard: SE, IR, 2D/3D GRE and SPGR, Angiography: 2D/3D TOF, 2D/3D phase contrast;; 2D/3D FSE, 2D/3D FRFSE, FGRE and FSPGR, SSFP, FLAIR, EPI, optional: 2D/3D Fiesta, fat/water separation, T1 FLAIR
IMAGING MODES Localizer, single slice, multislice, volume, fast, POMP, multi slab, cine, slice and frequency zip, extended dynamic range, tailored RF
TR 6 to 12000 msec in increments of 1 msec
TE 1.3 to 2000 msec in increments of 1 msec
SINGLE/MULTI SLICE Simultaneous scan and reconstruction;; 80 images/second reconstruction
FOV 3cm to 40 cm continuous
SLICE THICKNESS 2D: 2.7mm - 20mm 3D: 0.2mm - 5mm
DISPLAY MATRIX 1280 x 1024
MEASURING MATRIX 128x512 steps 32 phase//freq.
PIXEL INTENSITY 256 gray levels
SPATIAL RESOLUTION 0.08 mm; 0.02 mm optional
MAGNET TYPE Permanent
BORE DIAMETER
or W x H
120 x 44 cm
MAGNET WEIGHT 10,000 kg w/gradient enclosure
H*W*D 147 x 214 x 193 cm
POWER REQUIREMENTS 200 - 480, 3-phase
COOLING SYSTEM TYPE None required
CRYOGEN USE
FIELD STRENGTH 0.2 T
STRENGTH 15 mT/m
5-GAUSS FRINGE FIELD 1.7 m/1.7 m
spacer

• View the DATABASE results for 'Signa Profile™' (2).Open this link in a new window

MRI Resources 
Spectroscopy - Non-English - Pregnancy - Corporations - Safety Training - Collections
 
previous      16 - 20 (of 25)     next
Result Pages : [1]  [2 3]  [4 5]
 Random Page
 
Share This Page
FacebookTwitterLinkedIn

MR-TIP    
Community   
User
Pass
Forgot your UserID/Password ?  



Your MRI scanner(s) in 5 years should be :
more automated 
much quicker 
quiet 
voice controlled 
iPhone compatible 
as it is right now 

Look
      Ups





MR-TIP.com uses cookies! By browsing MR-TIP.com, you agree to our use of cookies.

Magnetic Resonance - Technology Information Portal
Member of SoftWays' Medical Imaging Group - MR-TIP • Radiology-TIP • US-TIP • 
Copyright © 2003 - 2018 SoftWays. All rights reserved. [ 21 May 2019]
Terms of Use | Privacy Policy | Advertising
 [last update: 2018-03-08 05:11:00]