Short name: PEG-APD (MnHA/PEG-APD), generic name: Manganese substituted hydroxylapatite, central moiety: Mn2+, relaxivity: r1=21.7, r2=26.9, B0=1.0 T
An intravascular MRI contrast agent under development (preclin.) for MR angiography.
spacer
MRI Resources 
Databases - Spectroscopy - Mobile MRI - Journals - Knee MRI - Pediatric and Fetal MRI
 
MetallofullerenesInfoSheet: - Contrast Agents - 
Intro, Overview, 
Characteristics, 
Types of, 
etc.
 
The paramagnetic water-soluble metallofullerenes (Gd-fullerenols), which have strong T1 shortening effect, can be used as a novel core material of MRI contrast agents. Gadolinium endohedral metallofullerenes have been synthesized as polyhydroxyl forms (Gd@C82(OH)n, Gd-fullerenes) with the evaluation of their paramagnetic properties. The modification to the water-soluble forms is essential for the biomedical application of the metallofullerenes. The in vitro water proton relaxivity, R1 (the effect on 1/T1), of Gd-fullerenes is significantly higher (20-folds) than that of commercial MRI contrast agents - e.g. Gd-DTPA.
spacer

• View the NEWS results for 'Metallofullerenes' (1).Open this link in a new window.
 
Further Reading:
  News & More:
A Single X-Ray Strike Is Enough to Destroy an Entire Molecule
Friday, 20 March 2020   by scitechdaily.com    
MRI Resources 
MRI Accidents - Directories - Functional MRI - Education pool - Implant and Prosthesis pool - Absorption and Emission
 
Mn(III)TPPS4InfoSheet: - Contrast Agents - 
Intro, Overview, 
Characteristics, 
Types of, 
etc.
 
Short name: Mn(III)TPPS4, chemical compound: manganese(III) tetra-[4- sulfanatophenyl] porphyrin, central moiety: Mn2+, relaxivity: r1=7.5, r2=8.6
Manganese(III) TPPS4 is an agent under development (preclin. for MRI contrast medium) with tumor selective uptake for tumor detection and control.

See also Metalloporphyrins.
spacer

• View the DATABASE results for 'Mn(III)TPPS4' (2).Open this link in a new window

MRI Resources 
Intraoperative MRI - Musculoskeletal and Joint MRI - Journals - Spectroscopy - Jobs - Veterinary MRI
 
Monocrystalline Iron Oxide NanoparticleInfoSheet: - Contrast Agents - 
Intro, Overview, 
Characteristics, 
Types of, 
etc.
 
Short name: MION, central moiety: Fe3+/Fe2+, relaxivity: r1=3.7, r2=6.5, B0=0.47T
MIONs are under development (preclin.) as contrast agents (taken up by the RES) for MR angiography, MR lymphography, tumor detection and detection of infarctioned tissue. Also called monodisperse iron oxide nanoparticles or nanocompounds.
spacer

• View the DATABASE results for 'Monocrystalline Iron Oxide Nanoparticle' (3).Open this link in a new window

 
Further Reading:
  Basics:
Biomedical scientist to test nanoparticles as early cancer detection agent
Monday, 28 October 2002
  News & More:
Turning up the heat on cancer
Thursday, 22 November 2007   by www.rsc.org    
Vascular Filters of Functional MRI: Spatial Localization Using BOLD and CBV Contrast
MRI Resources 
Universities - Breast Implant - Research Labs - Corporations - Blood Flow Imaging - Safety pool
 
Omniscan®InfoSheet: - Contrast Agents - 
Intro, Overview, 
Characteristics, 
Types of, 
etc.MRI Resource Directory:
 - Contrast Agents -
 
Omniscan® is a nonionic chelate complex with low osmolality used as a paramagnetic MRI contrast agent. The efficacy of Omniscan® is similar to that of Gd-DTPA. Omniscan® is given intravenously to enhance images of intracranial and spinal lesions where there is abnormal vascularity or an abnormal blood brain barrier. The complex does not cross an intact blood brain barrier so Omniscan® only accumulates in lesions such as neoplasm's and abscesses.

WARNING: NEPHROGENIC SYSTEMIC FIBROSIS Gadolinium-based contrast agents increase the risk for nephrogenic systemic fibrosis (NSF) in patients with acute or chronic severe renal insufficiency (glomerular filtration rate less than 30 mL/min/1.73m2), or acute renal insufficiency of any severity due to the hepato-renal syndrome or in the perioperative liver transplantation period.

See also Gadodiamide, and Classifications, Characteristics, etc.
Drug Information and Specification
NAME OF COMPOUND
Gadodiamide, Gd-DTPA-BMA
CENTRAL MOIETY
Gd2+
CONTRAST EFFECT
T1, Predominantly positive enhancement
r1=3.9, r2=4.3, B0=1.0T
PHARMACOKINETIC
Intravascular, extracellular, renal excretion
798 mosm/kgH2O
CONCENTRATION
287 mg/mL,0.5 mol/L
DOSAGE
0.1-0.2 mmol/kg / 0.2-0.4 ml/kg
PREPARATION
Finished product
INDICATION
Neuro/whole body
DEVELOPMENT STAGE
For sale
DISTRIBUTOR
See below
PRESENTATION
Vials of 10 mL, 15 mL and 20 mL
DO NOT RELY ON THE INFORMATION PROVIDED HERE, THEY ARE
NOT A SUBSTITUTE FOR THE ACCOMPANYING PACKAGE INSERT!
Distribution Information
TERRITORY
TRADE NAME
DEVELOPMENT
STAGE
DISTRIBUTOR
USA
Omniscan®
for sale
EU
Omniscan®
suspended
Australia
Omniscan®
for sale
spacer

• View the DATABASE results for 'Omniscan®' (7).Open this link in a new window

 
Further Reading:
  Basics:
Important Drug Warning for Gadolinium-Based Contrast Agents
Wednesday, 12 September 2007   by www.ismrm.org    
Omniscan Pharmacokinetics
  News & More:
Gadolinium-containing contrast agents: removal of Omniscan and iv Magnevist, restrictions to the use of other linear agents
Friday, 5 January 2018   by www.gov.uk    
Spurious Hypocalcemia After Omniscan- or OptiMARK-Enhanced Magnetic Resonance Imaging: An Algorithm for Minimizing a False-Positive Laboratory Value
October 2004   by www.findarticles.com    
MRI Resources 
Developers - - IR - Directories - Shielding - Abdominal Imaging
 
previous      36 - 40 (of 51)     next
Result Pages : [1]  [2 3 4 5 6 7 8 9 10 11]
 Random Page
 
Share This Page
FacebookTwitterLinkedIn

MR-TIP    
Community   
User
Pass
Forgot your UserID/Password ?    



Personalized protocols (age, gender, body habitus, etc.) lead to :
more automated planning 
improved patient comfort 
better diagnostics 
optimized image quality 
nothing 

Look
      Ups





MR-TIP.com uses cookies! By browsing MR-TIP.com, you agree to our use of cookies.