Magnetic Resonance - Technology Information Portal Welcome to MRI Technology
Info
  Sheets

Out-
      side
 



 
 'Relaxivity' 
SEARCH FOR    
 
  2 3 5 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Result : Searchterm 'Relaxivity' found in 1 term [] and 50 definitions []
previous     21 - 25 (of 51)     next
Result Pages : [1]  [2 3 4 5 6 7 8 9 10 11]
MRI Resources 
Spectroscopy pool - Musculoskeletal and Joint MRI - Raman Spectroscopy - Sequences - Lung Imaging - Education pool
 
Gadolite® Oral SuspensionInfoSheet: - Contrast Agents - 
Intro, Overview, 
Characteristics, 
Types of, 
etc.MRI Resource Directory:
 - Contrast Agents -
 
An oral suspension of synthetic crystalline aqueous orange-flavored MRI contrast agent to enhance delineation of the bowel. Gadolite contains gadolinium, a lanthanide metal with paramagnetic characteristics. The toxic Gd is bound to become inert, along with water, inside a zeolite crystalline lattice structure. Gadolite gives a bright signal, and provides improved definition of the gastrointestinal tract from adjacent tissues.
Pharmacyclics receives an approvable letter from the FDA for Gadolite® Oral Suspension and in the United Kingdom an European marketing agreement signed with E-Z-Em, Ltd. in Dec. 1996.
Drug Information and Specification
NAME OF COMPOUND
Gadolinium zeolite, Gadolinium chloride hexahydrate
CENTRAL MOIETY
Gd2+
CONTRAST EFFECT
T1, Predominantly positive enhancement
Paramagnetic
PHARMACOKINETIC
Gastrointestinal
PREPARATION
Oral suspension
INDICATION
Bowel marking
DEVELOPMENT STAGE
For sale
DISTRIBUTOR
See below
PRESENTATION
Suspension
DO NOT RELY ON THE INFORMATION PROVIDED HERE, THEY ARE
NOT A SUBSTITUTE FOR THE ACCOMPANYING PACKAGE INSERT!
Distribution Information
TERRITORY
TRADE NAME
DEVELOPMENT
STAGE
DISTRIBUTOR
USA, Canada, Mexico, EU
Gadolite® Oral Suspension
for sale
spacer
MRI Resources 
Shoulder MRI - Devices - Intraoperative MRI - Fluorescence - Corporations - MRI Training Courses
 
Gadomer 17InfoSheet: - Contrast Agents - 
Intro, Overview, 
Characteristics, 
Types of, 
etc.MRI Resource Directory:
 - Contrast Agents -
 
Short name: (Gd-DTPA)-17, 24 cascade polymer, generic name: Gadomer-17, 24, central moiety: Gd2+, relaxivity: r1=11.9, B0=1.0 T, r2=16.5, Dose: 0.05 mmol/kg
An intravascular macromolecular MRI contrast agent with positive enhancement under development (Bayer Schering Pharma AG) for MR angiography and tumor differentiation. The synthetic dendrimer with large molecular weight (17kD - limits agent to vascular space) is linked to Gadolinium. The renal excretion is slowed to intermediate molecular size. In MRA a longer lasting venous and arterial enhancement was seen with Gadomer-17 due to the particular pharmacokinetics of this agent.

See also Tumor Specific Agents, and Intravascular Contrast Agents.
spacer

• View the DATABASE results for 'Gadomer 17' (3).Open this link in a new window


• View the NEWS results for 'Gadomer 17' (1).Open this link in a new window.
 
Further Reading:
  News & More:
Combined MR lymphangiography and MR imaging-guided needle localization of sentinel lymph nodes using Gadomer-17.
2002
MRI Resources 
Databases - Hospitals - Stent - Absorption and Emission - Coils - Veterinary MRI
 
Gadovist®InfoSheet: - Contrast Agents - 
Intro, Overview, 
Characteristics, 
Types of, 
etc.MRI Resource Directory:
 - Contrast Agents -
 
Gadovist® is an extracellular, neutral macrocyclic (gadolinium (Gd) complex) MRI contrast agents for central nervous system indications, particularly suited for studies in which high doses are required or advantageous. Gadovist® (also Gadograf) was available in two concentrations, currently only Gadovist® 1.0 is marketed.
The product was approved in Switzerland in 1999 and in Germany in 2000. Gadovist® 1.0 is in USA currently in the drug development and approval process, particularly for magnetic resonance angiography.

WARNING: NEPHROGENIC SYSTEMIC FIBROSIS Gadolinium-based contrast agents increase the risk for nephrogenic systemic fibrosis (NSF) in patients with acute or chronic severe renal insufficiency (glomerular filtration rate less than 30 mL/min/1.73m2), or acute renal insufficiency of any severity due to the hepato-renal syndrome or in the perioperative liver transplantation period.

See also Paramagnetic Contrast Agents and Gadobutrol.
Drug Information and Specification
NAME OF COMPOUND
Gadobutrol, Gd-BT-DO3A
CENTRAL MOIETY
Gd2+
CONTRAST EFFECT
T1, Predominantly positive enhancement
r1=3.6, B0=1.0 T
PHARMACOKINETIC
Intravascular, extracellular, renal excretion
OSMOLALITY
557 and 1603 mosm/kgH2O
CONCENTRATION
1 mol/L
DOSAGE
0.1mmol/kg
PREPARATION
Finished product
INDICATION
Central nervous system / whole body
DEVELOPMENT STAGE
For sale / submit for approval
DISTRIBUTOR
See below
PRESENTATION
Vials of 15, 30 mL
DO NOT RELY ON THE INFORMATION PROVIDED HERE, THEY ARE
NOT A SUBSTITUTE FOR THE ACCOMPANYING PACKAGE INSERT!
Distribution Information
TERRITORY
TRADE NAME
DEVELOPMENT
STAGE
DISTRIBUTOR
USA
Gadovist®
Submit for approval
Japan
Gadovist®
EU
Gadovist®
for sale
Australia
Gadovist®
for sale
spacer

• View the DATABASE results for 'Gadovist®' (5).Open this link in a new window

 
Further Reading:
  Basics:
Important Drug Warning for Gadolinium-Based Contrast Agents
Wednesday, 12 September 2007   by www.ismrm.org    
Gadograf, Gadovist
Friday, 13 April 2007   by www.ema.europa.eu    
  News & More:
EMA's final opinion confirms restrictions on use of linear gadolinium agents in body scans
Friday, 21 July 2017   by www.ema.europa.eu    
FDA Drug Safety Communication: FDA warns that gadolinium-based contrast agents (GBCAs) are retained in the body; requires new class warnings
Tuesday, 19 December 2017   by www.fda.gov    
FDA approves Bayer's Gadavist® (gadobutrol) injection as the first magnetic resonance contrast agent for pediatric patients less than 2 years of age
Monday, 5 January 2015   by www.prnewswire.com    
New data presented at RSNA on use of Bayer's Gadavist® (gadobutrol) injection in children less than 2 years of age
Wednesday, 3 December 2014   by www.prnewswire.com    
MRI Resources 
Absorption and Emission - Functional MRI - Sequences - Contrast Agents - Implant and Prosthesis pool - Supplies
 
GastroMARK®InfoSheet: - Contrast Agents - 
Intro, Overview, 
Characteristics, 
Types of, 
etc.MRI Resource Directory:
 - Contrast Agents -
 
GastroMARK® belongs to the negative oral contrast agents (same as Lumirem®, another brand name for ferumoxsil). GastroMARK® is used to distinguish the loops of the bowel from other abdominal structures and physiology. When GastroMARK® is ingested, it flows through and darkens the stomach and the small intestine in 30 to 45 minutes. By more clearly identifying the intestinal loops, GastroMARK® improves visualization of adjacent abdominal tissues such as the pancreas.
Drug Information and Specification
NAME OF COMPOUND
Ferumoxsil, silicone-coated superparamagnetic iron oxide, USAN, AMI-121
CENTRAL MOIETY
Fe3+/Fe2+
CONTRAST EFFECT
T2*enhanced
r1=3.4, r2=3.8, B0=1.0T
PHARMACOKINETIC
Gastrointestinal
OSMOLALITY
250 mosm/kgH2O
CONCENTRATION
52.5mg Fe/300mL
DOSAGE
300 mL oral
PREPARATION
Finished product
INDICATION
Bowel marking
DEVELOPMENT STAGE
For sale
DISTRIBUTOR
See below
PRESENTATION
Bottles containing 300 mL
DO NOT RELY ON THE INFORMATION PROVIDED HERE, THEY ARE
NOT A SUBSTITUTE FOR THE ACCOMPANYING PACKAGE INSERT!
Distribution Information
TERRITORY
TRADE NAME
DEVELOPMENT
STAGE
DISTRIBUTOR
USA
GastroMARK®
For sale
spacer

• View the DATABASE results for 'GastroMARK®' (6).Open this link in a new window

 
Further Reading:
  Basics:
ferumoxsil, oral suspension GastroMARK GastroMARK ®
MATERIAL SAFETY DATA SHEET
   by dailymed.nlm.nih.gov    
MRI Resources 
Diffusion Weighted Imaging - Spine MRI - Service and Support - Mobile MRI Rental - Case Studies - Corporations
 
Gd-DTPA Labeled DextranInfoSheet: - Contrast Agents - 
Intro, Overview, 
Characteristics, 
Types of, 
etc.
 
Short name:(Gd-DTPA)n-dextran, central moiety: Gd2+
Gd-DTPA labeled dextran is a substance that has been tested as a blood pool agent (intravascular MRI contrast agent). Dextran is a polysaccharide and has labeled with 15 Gd-DTPA moieties a higher T1 relaxivity than unbound Gd-DTPA, compared with a high safety level.

See also Intravascular Contrast Agents, Blood Pool Agents.
spacer

• View the DATABASE results for 'Gd-DTPA Labeled Dextran' (2).Open this link in a new window

 
Further Reading:
  Basics:
Evaluation of Gd-DTPA-labeled dextran as an intravascular MR contrast agent: imaging characteristics in normal rat tissues
   by radiology.rsnajnls.org    
MRI Resources 
MRI Reimbursement - Spine MRI - Contrast Agents - Sequences - Societies - Veterinary MRI
 
previous      21 - 25 (of 51)     next
Result Pages : [1]  [2 3 4 5 6 7 8 9 10 11]
 Random Page
 
Share This Page
FacebookTwitterLinkedIn

MR-TIP    
Community   
User
Pass
Forgot your UserID/Password ?    



Next big thing in MRI will be :
AI 
remote operator 
personalized protocols 
helium-free 
molecular MRI 
portable MRI 

Look
      Ups





MR-TIP.com uses cookies! By browsing MR-TIP.com, you agree to our use of cookies.

Magnetic Resonance - Technology Information Portal
Member of SoftWays' Medical Imaging Group - MR-TIP • Radiology-TIP • Medical-Ultrasound-Imaging • 
Copyright © 2003 - 2024 SoftWays. All rights reserved. [ 25 April 2024]
Terms of Use | Privacy Policy | Advertising
 [last update: 2024-02-26 03:41:00]