Vasovist™InfoSheet: - Contrast Agents - 
Intro, Overview, 
Characteristics, 
Types of, 
etc.MRI Resource Directory:
 - Contrast Agents -
 
Vasovist™ is an albumin-targeted intravascular contrast agent. It is indicated for contrast enhanced MR angiography (CE-MRA) for the visualization of abdominal or limb vessels in patients with suspected or known vascular disease. After IV injection, Vasovist™ binds reversibly to human albumin in plasma, which results in long-lasting increased relaxivity. Imaging from 5 to 50 min is possible. A small unbound portion is, by glomerular filtration, eliminated by the kidneys.
AngioMARK® was the formerly trade name and MS-325 the research name. Currently the phase III clinical trials are completed to determine its efficacy for peripheral vascular disease and coronary artery disease.
In the U.S., EPIX received an approvable letter from the U.S. Food and Drug Administration (FDA) for Vasovist™ in January 2005. In 2009, Epix Pharmaceuticals has sold the U.S., Canadian and Australian rights for its blood pool agent (now named ABLAVAR™), to Lantheus Medical Imaging, Inc..

WARNING: NEPHROGENIC SYSTEMIC FIBROSIS Gadolinium-based contrast agents increase the risk for nephrogenic systemic fibrosis (NSF) in patients with acute or chronic severe renal insufficiency (glomerular filtration rate less than 30 mL/min/1.73m2), or acute renal insufficiency of any severity due to the hepato-renal syndrome or the liver transplantation period.

See also MRI Safety.
Drug Information and Specification
NAME OF COMPOUND
Diphenylcyclohexyl phosphodiester-Gd-DTPA, gadofosveset trisodium, MS-325
CENTRAL MOIETY
Gd2+
CONTRAST EFFECT
T1, predominantly positive enhancement
20-45 mmol-1sec-1, Bo=0,47T
PHARMACOKINETIC
Intravascular, short elimination half life
825 mOsmol/kg H2O
CONCENTRATION
244 mg/mL, 0.25mmol/mL
DOSAGE
0.12 mL/kg, 0.03 mmol/kg
PREPARATION
ready to use
DEVELOPMENT STAGE
approved
DISTRIBUTOR
See below
PRESENTATION
10 mL vials
DO NOT RELY ON THE INFORMATION PROVIDED HERE, THEY ARE
NOT A SUBSTITUTE FOR THE ACCOMPANYING PACKAGE INSERT!
Distribution Information
TERRITORY
TRADE NAME
DEVELOPMENT
STAGE
DISTRIBUTOR
EU
Vasovist™
?
?
North America, Australia
for sale
spacer
 
Further Reading:
  Basics:
EPIX Medical's new multimedia Web site features AngioMARK images in 3D
Friday, 5 March 1999
MRI technology combined with contrast agent optimizes diagnosis of cardiovascular disease
1999
MRI Resources 
MRI Technician and Technologist Jobs - Devices - Hospitals - Quality Advice - Knee MRI - MRCP
 
Abdoscan®InfoSheet: - Contrast Agents - 
Intro, Overview, 
Characteristics, 
Types of, 
etc.MRI Resource Directory:
 - Contrast Agents -
 
This superparamagnetic oral contrast agent consists of large iron oxide particles, coated with insoluble material. Abdoscan® particles have a mean diameter no less than 300 nm. Gastrointestinal superparamagnetic contrast agents are used for negative bowel enhancement.

Abdoscan® was approved in Europe but was taken off the market in 2000, and all sales stopped by the end of 2002.
Drug Information and Specification
NAME OF COMPOUND
DEVELOPER
CENTRAL MOIETY
Fe2+/Fe3+
CONTRAST EFFECT
T2*, predominantly negative enhancement
PHARMACOKINETIC
Gastrointestinal
CONCENTRATION
23.4 Fe/200ml
PREPARATION
Dissolve
INDICATION
Bowel marking
DEVELOPMENT STAGE
Not FDA approved
PRESENTATION
Bags with powder
DO NOT RELY ON THE INFORMATION PROVIDED HERE, THEY ARE
NOT A SUBSTITUTE FOR THE ACCOMPANYING PACKAGE INSERT!
spacer

• View the DATABASE results for 'Abdoscan®' (2).Open this link in a new window

MRI Resources 
MR Guided Interventions - Most Wanted - MRI Technician and Technologist Jobs - Contrast Enhanced MRI - Open Directory Project - Blood Flow Imaging
 
Artirem®InfoSheet: - Contrast Agents - 
Intro, Overview, 
Characteristics, 
Types of, 
etc.MRI Resource Directory:
 - Contrast Agents -
 
Artirem®, the arthrography-specific contrast agent for MRI is a dilute form of Dotarem® with a less concentration of Gd (1:200). Artirem® has to be injected directly into the joints for better visualization and delimitation, of the ligament and tendon structures in particular.
Drug Information and Specification
NAME OF COMPOUND
DEVELOPER
CENTRAL MOIETY
Gd2+
CONTRAST EFFECT
T1, Predominantly positive enhancement
r1=3.4, r2=4.8, B0=1.0T
PHARMACOKINETIC
Intravascular, extracellular, renal excretion
CONCENTRATION
0,0025 mmol/ml
PREPARATION
Finished product
INDICATION
Arthrography
DEVELOPMENT STAGE
For sale
DISTRIBUTOR
See below
PRESENTATION
Pre-filled syringes of 20 mL
DO NOT RELY ON THE INFORMATION PROVIDED HERE, THEY ARE
NOT A SUBSTITUTE FOR THE ACCOMPANYING PACKAGE INSERT!
Distribution Information
TERRITORY
TRADE NAME
DEVELOPMENT
STAGE
DISTRIBUTOR
EU
for sale
France, Switzerland
Artirem®
for sale
Australia
for sale
spacer

• View the DATABASE results for 'Artirem®' (4).Open this link in a new window

 
Further Reading:
  News & More:
EMA's final opinion confirms restrictions on use of linear gadolinium agents in body scans
Friday, 21 July 2017   by www.ema.europa.eu    
MRI Resources 
Musculoskeletal and Joint MRI - Pregnancy - Developers - Patient Information - MRI Technician and Technologist Career - Process Analysis
 
CEIV-7InfoSheet: - Contrast Agents - 
Intro, Overview, 
Characteristics, 
Types of, 
etc.MRI Resource Directory:
 - Contrast Agents -
 
Short name: CEIV-7, central moiety: Gd
A paramagnetic chelate with capabilities as a multipurpose T1-relaxivity necrosis avid MRI contrast agent.

See also Necrosis Avid Contrast Agent.
spacer
MRI Resources 
MRA - RIS - Directories - Musculoskeletal and Joint MRI - Image Quality - Non-English
 
Clariscan™InfoSheet: - Contrast Agents - 
Intro, Overview, 
Characteristics, 
Types of, 
etc.MRI Resource Directory:
 - Contrast Agents -
 
An iron-based contrast agent with large molecular size, which prevents diffusion into body tissues and will be developed for MR imaging of the liver (taken up by macrophages), tumor microvasculature and microvessel permeability. The blood half live of the particles with 11-20 nm diameter is 3-4 hours.
At this time the development of Clariscan™ is discontinued.

See also NC100150 Injection and Ultrasmall Superparamagnetic Iron Oxide.
Drug Information and Specification
NAME OF COMPOUND
Feruglose, PEG-feron, USPIO, NC100150
DEVELOPER
CENTRAL MOIETY
Fe
CONTRAST EFFECT
T2, Predominantly negative enhancement
R1=20, R2=35, B0=0.5T
PHARMACOKINETIC
Intravascular
CONCENTRATION
29.8 mg Fe/mL
PREPARATION
Suspend in an isotonic glucose solution
INDICATION
Cardiovascular
DEVELOPMENT STAGE
?
DO NOT RELY ON THE INFORMATION PROVIDED HERE, THEY ARE
NOT A SUBSTITUTE FOR THE ACCOMPANYING PACKAGE INSERT!
spacer

• View the DATABASE results for 'Clariscan™' (6).Open this link in a new window

 
Further Reading:
  News & More:
GE Healthcare expands MRI contrast media product range in Europe with launch of macrocyclic agent ClariscanTM
Wednesday, 1 March 2017   by www.businesswire.com    
GE Healthcare announces FDA approval of macrocyclic MRI contrast agent Clariscan
Monday, 4 November 2019   by www.itnonline.com    
MRI Resources 
Cardiovascular Imaging - Distributors - Anatomy - Safety pool - Pregnancy - Calculation
 
previous      6 - 10 (of 51)     next
Result Pages : [1]  [2 3 4 5 6 7 8 9 10 11]
 Random Page
 
Share This Page
FacebookTwitterLinkedIn

MR-TIP    
Community   
User
Pass
Forgot your UserID/Password ?    



Personalized protocols (age, gender, body habitus, etc.) lead to :
more automated planning 
improved patient comfort 
better diagnostics 
optimized image quality 
nothing 

Look
      Ups





MR-TIP.com uses cookies! By browsing MR-TIP.com, you agree to our use of cookies.

Magnetic Resonance - Technology Information Portal
Member of SoftWays' Medical Imaging Group - MR-TIP • Radiology-TIP • Medical-Ultrasound-Imaging • 
Copyright © 2003 - 2024 SoftWays. All rights reserved. [ 19 April 2024]
Terms of Use | Privacy Policy | Advertising
 [last update: 2024-02-26 03:41:00]