Magnetic Resonance - Technology Information Portal Welcome to MRI Technology
Info
  Sheets

Out-
      side
 



 
 'Real' 
SEARCH FOR    
 
  2 3 5 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Result : Searchterm 'Real' found in 4 terms [] and 43 definitions []
1 - 5 (of 47)     next
Result Pages : [1]  [2 3 4 5 6 7 8 9 10]
Searchterm 'Real' was also found in the following services: 
spacer
News  (47)  Resources  (9)  Forum  (34)  
 
RealForum -
related threads
 
A real number is a component of a complex number. In MRI, complex data are used for example in the Fourier transforms.
spacer
 
• Share the entry 'Real':  Facebook  Twitter  LinkedIn  

• View the NEWS results for 'Real' (16).Open this link in a new window.
 
Further Reading:
  Basics:
Complex Number
   by en.wikipedia.org    
Searchterm 'Real' was also found in the following services: 
spacer
Radiology  (9) Open this link in a new windowUltrasound  (52) Open this link in a new window
Real Time
 
Immediate display of reconstructed images during the scan time. Also called online display.
spacer

• View the DATABASE results for 'Real Time' (5).Open this link in a new window


• View the NEWS results for 'Real Time' (6).Open this link in a new window.
 
Further Reading:
  News & More:
New e-Incubator enables real-time imaging of bioengineered tissues in controlled unit
Wednesday, 5 November 2014   by www.eurekalert.org    
University of Texas supercomputer speeds real-time MRI analysis
Thursday, 2 March 2017   by www.information-management.com    
Brain scans read your mind
Tuesday, 22 June 2010   by msnbc.msn.com    
New prostate cancer imaging shows real-time tumor metabolism
Monday, 29 November 2010   by www.eurekalert.org    
MRI Resources 
Cardiovascular Imaging - Calculation - General - Process Analysis - Journals - Spine MRI
 
Real Signal
 
In phase component of signal detected with a quadrature detector.
spacer
Searchterm 'Real' was also found in the following services: 
spacer
News  (47)  Resources  (9)  Forum  (34)  
 
Interactive Real Time
 
Change of the measurement parameters in real time.
spacer
Searchterm 'Real' was also found in the following services: 
spacer
Radiology  (9) Open this link in a new windowUltrasound  (52) Open this link in a new window
Partial Fourier Technique
 
The partial Fourier technique is a modification of the Fourier transformation imaging method used in MRI in which the symmetry of the raw data in k-space is used to reduce the data acquisition time by acquiring only a part of k-space data.
The symmetry in k-space is a basic property of Fourier transformation and is called Hermitian symmetry. Thus, for the case of a real valued function g, the data on one half of k-space can be used to generate the data on the other half.
Utilization of this symmetry to reduce the acquisition time depends on whether the MRI problem obeys the assumption made above, i.e. that the function being characterized is real.
The function imaged in MRI is the distribution of transverse magnetization Mxy, which is a vector quantity having a magnitude, and a direction in the transverse plane. A convenient mathematical notation is to use a complex number to denote a vector quantity such as the transverse magnetization, by assigning the x'-component of the magnetization to the real part of the number and the y'-component to the imaginary part. (Sometimes, this mathematical convenience is stretched somewhat, and the magnetization is described as having a real component and an imaginary component. Physically, the x' and y' components of Mxy are equally 'real' in the tangible sense.)
Thus, from the known symmetry properties for the Fourier transformation of a real valued function, if the transverse magnetization is entirely in the x'-component (i.e. the y'-component is zero), then an image can be formed from the data for only half of k-space (ignoring the effects of the imaging gradients, e.g. the readout- and phase encoding gradients).
The conditions under which Hermitian symmetry holds and the corrections that must be applied when the assumption is not strictly obeyed must be considered.
There are a variety of factors that can change the phase of the transverse magnetization:
Off resonance (e.g. chemical shift and magnetic field inhomogeneity cause local phase shifts in gradient echo pulse sequences. This is less of a problem in spin echo pulse sequences.
Flow and motion in the presence of gradients also cause phase shifts.
Effects of the radio frequency RF pulses can also cause phase shifts in the image, especially when different coils are used to transmit and receive.
Only, if one can assume that the phase shifts are slowly varying across the object (i.e. not completely independent in each pixel) significant benefits can still be obtained. To avoid problems due to slowly varying phase shifts in the object, more than one half of k-space must be covered. Thus, both sides of k-space are measured in a low spatial frequency range while at higher frequencies they are measured only on one side. The fully sampled low frequency portion is used to characterize (and correct for) the slowly varying phase shifts.
Several reconstruction algorithms are available to achieve this. The size of the fully sampled region is dependent on the spatial frequency content of the phase shifts. The partial Fourier method can be employed to reduce the number of phase encoding values used and therefore to reduce the scan time. This method is sometimes called half-NEX, 3/4-NEX imaging, etc. (NEX/NSA). The scan time reduction comes at the expense of signal to noise ratio (SNR).
Partial k-space coverage is also useable in the readout direction. To accomplish this, the dephasing gradient in the readout direction is reduced, and the duration of the readout gradient and the data acquisition window are shortened.
This is often used in gradient echo imaging to reduce the echo time (TE). The benefit is at the expense in SNR, although this may be partly offset by the reduced echo time. Partial Fourier imaging should not be used when phase information is eligible, as in phase contrast angiography.

See also acronyms for 'partial Fourier techniques' from different manufacturers.
spacer

• View the DATABASE results for 'Partial Fourier Technique' (6).Open this link in a new window

MRI Resources 
Artifacts - Societies - Spine MRI - MR Guided Interventions - Directories - Claustrophobia
 
     1 - 5 (of 47)     next
Result Pages : [1]  [2 3 4 5 6 7 8 9 10]
 Random Page
 
Share This Page
FacebookTwitterLinkedIn

MR-TIP    
Community   
User
Pass
Forgot your UserID/Password ?    



MRI is trending to low field magnets :
reduced costs will lead to this change 
AI will close the gap to high field 
only in remote areas 
is only temporary 
never 

Look
      Ups





MR-TIP.com uses cookies! By browsing MR-TIP.com, you agree to our use of cookies.

Magnetic Resonance - Technology Information Portal
Member of SoftWays' Medical Imaging Group - MR-TIP • Radiology-TIP • Medical-Ultrasound-Imaging • 
Copyright © 2003 - 2024 SoftWays. All rights reserved. [ 19 April 2024]
Terms of Use | Privacy Policy | Advertising
 [last update: 2024-02-26 03:41:00]