Magnetic Resonance - Technology Information Portal Welcome to MRI Technology
Info
  Sheets

Out-
      side
 



 
 'Paramagnetic Contrast Agents' 
SEARCH FOR    
 
  2 3 5 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Result : Searchterm 'Paramagnetic Contrast Agents' found in 4 terms [] and 18 definitions []
previous     11 - 15 (of 22)     next
Result Pages : [1]  [2 3 4 5]
Searchterm 'Paramagnetic Contrast Agents' was also found in the following services: 
spacer
News  (2)  Resources  (1)  Forum  (1)  
 
Contrast AgentsForum -
related threadsInfoSheet: - Contrast Agents - 
Intro, Overview, 
Characteristics, 
Types of, 
etc.MRI Resource Directory:
 - Contrast Agents -
 
Contrast agents are chemical substances introduced to the anatomical or functional region being imaged, to increase the differences between different tissues or between normal and abnormal tissue, by altering the relaxation times. MRI contrast agents are classified by the different changes in relaxation times after their injection.
•
Positive contrast agents cause a reduction in the T1 relaxation time (increased signal intensity on T1 weighted images). They (appearing bright on MRI) are typically small molecular weight compounds containing as their active element Gadolinium, Manganese, or Iron. All of these elements have unpaired electron spins in their outer shells and long relaxivities.
Some typical contrast agents as gadopentetate dimeglumine, gadoteridol, and gadoterate meglumine are utilized for the central nervous system and the complete body; mangafodipir trisodium is specially used for lesions of the liver and gadodiamide for the central nervous system.
•
Negative contrast agents (appearing predominantly dark on MRI) are small particulate aggregates often termed superparamagnetic iron oxide (SPIO). These agents produce predominantly spin spin relaxation effects (local field inhomogeneities), which results in shorter T1 and T2 relaxation times.
SPIO's and ultrasmall superparamagnetic iron oxides (USPIO) usually consist of a crystalline iron oxide core containing thousands of iron atoms and a shell of polymer, dextran, polyethyleneglycol, and produce very high T2 relaxivities. USPIOs smaller than 300 nm cause a substantial T1 relaxation. T2 weighted effects are predominant.
•
A special group of negative contrast agents (appearing dark on MRI) are perfluorocarbons (perfluorochemicals), because their presence excludes the hydrogen atoms responsible for the signal in MR imaging.

The design objectives for the next generation of MR contrast agents will likely focus on prolonging intravascular retention, improving tissue targeting, and accessing new contrast mechanisms. Macromolecular paramagnetic contrast agents are being tested worldwide. Preclinical data shows that these agents demonstrate great promise for improving the quality of MR angiography, and in quantificating capillary permeability and myocardial perfusion.
Ultrasmall superparamagnetic iron oxide (USPIO) particles have been evaluated in multicenter clinical trials for lymph node MR imaging and MR angiography, with the clinical impact under discussion. In addition, a wide variety of vector and carrier molecules, including antibodies, peptides, proteins, polysaccharides, liposomes, and cells have been developed to deliver magnetic labels to specific sites. Technical advances in MR imaging will further increase the efficacy and necessity of tissue-specific MRI contrast agents.

See also Adverse Reaction and Nephrogenic Systemic Fibrosis.

See also the related poll result: 'The development of contrast agents in MRI is'
 
Images, Movies, Sliders:
 Delayed Myocardial Contrast Enhancement from Infarct  Open this link in a new window
      

Courtesy of  Robert R. Edelman
 Left Circumflex Ischemia First-pass Contrast Enhancement  Open this link in a new window
 MR Colonography Gadolinium per Rectum  Open this link in a new window
      

Courtesy of  Robert R. Edelman
 CE MRA of the Aorta  Open this link in a new window
    
SlidersSliders Overview

 
Radiology-tip.comradContrast Agents,  Safety of Contrast Agents
spacer
Medical-Ultrasound-Imaging.comUltrasound Contrast Agents,  Ultrasound Contrast Agent Safety
spacer
 
• Related Searches:
    • Contrast Enhanced Magnetic Resonance Angiography
    • Contrast Enhanced MRI
    • Contrast Medium
    • Blood Pool Agents
    • Breast MRI
 
Further Reading:
  Basics:
Analysis of MRI contrast agents
Thursday, 17 November 2022   by www.sciencedaily.com    
New guidelines urge caution on use of contrast agents during MR scans
Tuesday, 8 August 2017   by www.dotmed.com    
New Study Sheds Light on Safety of Gadolinium-Based Contrast Agents
Wednesday, 29 November 2017   by www.empr.com    
A safer approach for diagnostic medical imaging
Monday, 29 September 2014   by www.eurekalert.org    
Manganese-based MRI contrast agents: past, present and future
Friday, 4 November 2011   by www.ncbi.nlm.nih.gov    
  News & More:
Brain imaging method may aid mild traumatic brain injury diagnosis
Tuesday, 16 January 2024   by parkinsonsnewstoday.com    
A Targeted Multi-Crystalline Manganese Oxide as a Tumor-Selective Nano-Sized MRI Contrast Agent for Early and Accurate Diagnosis of Tumors
Thursday, 18 January 2024   by www.dovepress.com    
FDA Approves Gadopiclenol for Contrast-Enhanced Magnetic Resonance Imaging
Tuesday, 27 September 2022   by www.pharmacytimes.com    
How to stop using gadolinium chelates for magnetic resonance imaging: clinical-translational experiences with ferumoxytol
Saturday, 5 February 2022   by www.ncbi.nlm.nih.gov    
Estimation of Contrast Agent Concentration in DCE-MRI Using 2 Flip Angles
Tuesday, 11 January 2022   by pubmed.ncbi.nlm.nih.gov    
Manganese enhanced MRI provides more accurate details of heart function after a heart attack
Tuesday, 11 May 2021   by www.news-medical.net    
Gadopiclenol: positive results for Phase III clinical trials
Monday, 29 March 2021   by www.pharmiweb.co    
Gadolinium-Based Contrast Agents Hypersensitivity: A Case Series
Friday, 4 December 2020   by www.dovepress.com    
Polysaccharide-Core Contrast Agent as Gadolinium Alternative for Vascular MR
Monday, 8 March 2021   by www.diagnosticimaging.com    
Water-based non-toxic MRI contrast agents
Monday, 11 May 2020   by chemistrycommunity.nature.com    
New method to detect early-stage cancer identified by Georgia State, Emory research team
Friday, 7 February 2020   by www.eurekalert.org    
Researchers Brighten Path for Creating New Type of MRI Contrast Agent
Friday, 7 February 2020   by www.newswise.com    
Manganese-based MRI contrast agent may be safer alternative to gadolinium-based agents
Wednesday, 15 November 2017   by www.eurekalert.org    
Sodium MRI May Show Biomarker for Migraine
Friday, 1 December 2017   by psychcentral.com    
A natural boost for MRI scans
Monday, 21 October 2013   by www.eurekalert.org    
For MRI, time is of the essence A new generation of contrast agents could make for faster and more accurate imaging
Tuesday, 28 June 2011   by scienceline.org    
MRI Resources 
Fluorescence - Jobs - Colonography - Examinations - Nerve Stimulator - Service and Support
 
FerucarbotranInfoSheet: - Contrast Agents - 
Intro, Overview, 
Characteristics, 
Types of, 
etc.
 
Short name: SHU 555 A, generic name: Ferucarbotran
A RES-directed MRI contrast agent (SPIO) made-up of a colloidal sol of iron oxide nanoparticles coated with carboxydextran (Resovist®, Cliavist™).
It is used for the detection and characterization of especially small focal liver lesions and offers the opportunity to make a reliable diagnosis at a very early stage of patients with suspected liver tumors.
Bayer Schering Pharma AG announced that it has received marketing approval for the liver-specific contrast agent Resovist® in Japan. See Contrast Agents and Superparamagnetic Contrast Agents.
spacer

• View the DATABASE results for 'Ferucarbotran' (4).Open this link in a new window

MRI Resources 
Breast MRI - Education pool - Education - Diffusion Weighted Imaging - MRI Accidents - Chemistry
 
Gadolinium OxideInfoSheet: - Contrast Agents - 
Intro, Overview, 
Characteristics, 
Types of, 
etc.
 
Gadolinium oxide (Gd2O3) is a prototype paramagnetic agent for contrast enhanced MRI. Gd2O3 particles have very high relaxivity. With its high magnetic moment, gadolinium reduces the relaxation time and enhance MR signal intensity. All gadolinium compounds are highly toxic. Very stable complexes are developed to eliminate the toxicity. See also Paramagnetic Substance, Paramagnetism, Paramagnetic Contrast Agents and Contrast Agents, the info sheet gives an overview and more in-dept information about different types of MRI Contrast media.
spacer

• View the DATABASE results for 'Gadolinium Oxide' (2).Open this link in a new window

 
Further Reading:
  Basics:
Gadolinium oxide nanoparticles enhance MRI contrast
Thursday, 29 September 2011   by nanotechweb.org    
  News & More:
Northern Rare Earth eyes medical device prospects
Thursday, 29 December 2016   by usa.chinadaily.com.cn    
Searchterm 'Paramagnetic Contrast Agents' was also found in the following services: 
spacer
News  (2)  Resources  (1)  Forum  (1)  
 
Gadovist®InfoSheet: - Contrast Agents - 
Intro, Overview, 
Characteristics, 
Types of, 
etc.MRI Resource Directory:
 - Contrast Agents -
 
Gadovist® is an extracellular, neutral macrocyclic (gadolinium (Gd) complex) MRI contrast agents for central nervous system indications, particularly suited for studies in which high doses are required or advantageous. Gadovist® (also Gadograf) was available in two concentrations, currently only Gadovist® 1.0 is marketed.
The product was approved in Switzerland in 1999 and in Germany in 2000. Gadovist® 1.0 is in USA currently in the drug development and approval process, particularly for magnetic resonance angiography.

WARNING: NEPHROGENIC SYSTEMIC FIBROSIS Gadolinium-based contrast agents increase the risk for nephrogenic systemic fibrosis (NSF) in patients with acute or chronic severe renal insufficiency (glomerular filtration rate less than 30 mL/min/1.73m2), or acute renal insufficiency of any severity due to the hepato-renal syndrome or in the perioperative liver transplantation period.

See also Paramagnetic Contrast Agents and Gadobutrol.
Drug Information and Specification
NAME OF COMPOUND
Gadobutrol, Gd-BT-DO3A
CENTRAL MOIETY
Gd2+
CONTRAST EFFECT
T1, Predominantly positive enhancement
r1=3.6, B0=1.0 T
PHARMACOKINETIC
Intravascular, extracellular, renal excretion
OSMOLALITY
557 and 1603 mosm/kgH2O
CONCENTRATION
1 mol/L
DOSAGE
0.1mmol/kg
PREPARATION
Finished product
INDICATION
Central nervous system / whole body
DEVELOPMENT STAGE
For sale / submit for approval
DISTRIBUTOR
See below
PRESENTATION
Vials of 15, 30 mL
DO NOT RELY ON THE INFORMATION PROVIDED HERE, THEY ARE
NOT A SUBSTITUTE FOR THE ACCOMPANYING PACKAGE INSERT!
Distribution Information
TERRITORY
TRADE NAME
DEVELOPMENT
STAGE
DISTRIBUTOR
USA
Gadovist®
Submit for approval
Japan
Gadovist®
EU
Gadovist®
for sale
Australia
Gadovist®
for sale
spacer

• View the DATABASE results for 'Gadovist®' (5).Open this link in a new window

 
Further Reading:
  Basics:
Important Drug Warning for Gadolinium-Based Contrast Agents
Wednesday, 12 September 2007   by www.ismrm.org    
Gadograf, Gadovist
Friday, 13 April 2007   by www.ema.europa.eu    
  News & More:
EMA's final opinion confirms restrictions on use of linear gadolinium agents in body scans
Friday, 21 July 2017   by www.ema.europa.eu    
FDA Drug Safety Communication: FDA warns that gadolinium-based contrast agents (GBCAs) are retained in the body; requires new class warnings
Tuesday, 19 December 2017   by www.fda.gov    
FDA approves Bayer's Gadavist® (gadobutrol) injection as the first magnetic resonance contrast agent for pediatric patients less than 2 years of age
Monday, 5 January 2015   by www.prnewswire.com    
New data presented at RSNA on use of Bayer's Gadavist® (gadobutrol) injection in children less than 2 years of age
Wednesday, 3 December 2014   by www.prnewswire.com    
MRI Resources 
General - Raman Spectroscopy - Liver Imaging - Services and Supplies - Brain MRI - Chemistry
 
HaemoglobinInfoSheet: - Contrast Agents - 
Intro, Overview, 
Characteristics, 
Types of, 
etc.
 
(Hb) Haemoglobin is the major endogenous oxygen-binding molecule, responsible for binding oxygen in the lung and transporting it to the tissues by means of the circulation. Haemoglobin is contained in very high concentration in the red blood cells.
Haemoglobin is an Fe chelate tightly binding one Fe ion in its II oxidation state where it carries the charge 2+ (ferrous iron). If an oxygen molecule is bound to Hb, Hb is called oxyhaemoglobin, if no oxygen molecule is bound it is called deoxyhaemoglobin. When haemoglobin is oxidized (i.e. in a haematoma), Fe2+ is transformed into Fe3+. The resulting haemoglobin is then called metoxyhaemoglobin (Hb Fe3+).
Deoxyhaemoglobin and metoxyhaemoglobin act as paramagnetic contrast agents in MR, while oxyhaemoglobin is diamagnetic. This partly explains the special appearance of an aging haematoma in MR imaging and is also the basic of the blood oxygenation level dependent contrast (BOLD) used in functional magnetic resonance imaging of the brain (fMRI).
spacer

• View the DATABASE results for 'Haemoglobin' (10).Open this link in a new window

 
Further Reading:
  Basics:
MRI's inside story
Thursday, 4 December 2003   by www.economist.com    
  News & More:
MRI effectively measures hemochromatosis iron burden
Saturday, 3 October 2015   by medicalxpress.com    
Iron overload: accuracy of in-phase and out-of-phase MRI as a quick method to evaluate liver iron load in haematological malignancies and chronic liver disease
Friday, 1 June 2012   by www.ncbi.nlm.nih.gov    
EVALUATION OF HUMAN STROKE BY MR IMAGING
2000
MRI Resources 
Intraoperative MRI - Education pool - Veterinary MRI - Resources - Spine MRI - Patient Information
 
previous      11 - 15 (of 22)     next
Result Pages : [1]  [2 3 4 5]
 Random Page
 
Share This Page
FacebookTwitterLinkedIn

MR-TIP    
Community   
User
Pass
Forgot your UserID/Password ?    



Personalized protocols (age, gender, body habitus, etc.) lead to :
more automated planning 
improved patient comfort 
better diagnostics 
optimized image quality 
nothing 

Look
      Ups





MR-TIP.com uses cookies! By browsing MR-TIP.com, you agree to our use of cookies.

Magnetic Resonance - Technology Information Portal
Member of SoftWays' Medical Imaging Group - MR-TIP • Radiology-TIP • Medical-Ultrasound-Imaging • 
Copyright © 2003 - 2024 SoftWays. All rights reserved. [ 24 April 2024]
Terms of Use | Privacy Policy | Advertising
 [last update: 2024-02-26 03:41:00]