Magnetic Resonance - Technology Information Portal Welcome to MRI Technology
Info
  Sheets

Out-
      side
 



 
 'Paramagnetic Contrast Agents' 
SEARCH FOR    
 
  2 3 5 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Result : Searchterm 'Paramagnetic Contrast Agents' found in 4 terms [] and 18 definitions []
previous     6 - 10 (of 22)     next
Result Pages : [1]  [2 3 4 5]
Searchterm 'Paramagnetic Contrast Agents' was also found in the following services: 
spacer
News  (2)  Resources  (1)  Forum  (1)  
 
Negative Oral Contrast AgentsForum -
related threadsInfoSheet: - Contrast Agents - 
Intro, Overview, 
Characteristics, 
Types of, 
etc.MRI Resource Directory:
 - Contrast Agents -
 
Categories of negative oral contrast agents:
Negative oral contrast media are usually based on superparamagnetic particles and act by inducing local field inhomogeneities, which results in shortening of both T1 and T2 relaxation times. Superparamagnetic contrast agents have predominant T2 weighted effects. Biphasic contrast media are agents that have different signal intensities on different sequences, depending on the concentration at which they are used.
Suitable materials for oral contrast agents should have little or no absorption by the stomach or intestines, complete excretion, no motion or susceptibility artifacts, affordability, and uniform marking of the gastrointestinal tract. Benefits of negative oral contrast agents are the reduction of ghosting artifacts caused by the lack of signal. Superparamagnetic iron oxides produce also in low concentrations a noticeable signal loss; but can generate susceptibility artifacts especially in gradient echo sequences. Perfluorochemicals do not dilute in the bowel because they are not miscible with water.
High cost, poor availability, and limited evaluations of side effects are possible disadvantages.
Negative oral contrast agents are used e.g., in MRCP, where the ingestion of 600-900 ml of SPIO cancels out the signal intensity of the lumen (in addition after the injection of a gadolinium-based contrast medium, the enhancement of the inflammatory tissues is clearer seen), and in MR abdominal imaging of Crohn's disease in combination with mannitol.
mri safety guidance
Contrast Guidance
Blueberry or pineapple juices are useable for examinations of the pancreas (MRCP, upper abdominal imaging) as cheep contrast agents, because of the content of magnetic substances (e.g. manganese).

See also Ferristene, Ferumoxsil, Oral Magnetic Particles, Gastrointestinal Imaging.
spacer
 
Further Reading:
  Basics:
Components of Oral Contrast Agent for Magnetic Resonance Imaging(.pdf)
   by www.ffcr.or.jp    
MRI Resources 
Raman Spectroscopy - Shielding - Supplies - Contrast Agents - Journals -
 
Oral Contrast AgentsForum -
related threadsInfoSheet: - Contrast Agents - 
Intro, Overview, 
Characteristics, 
Types of, 
etc.MRI Resource Directory:
 - Contrast Agents -
 
A limitation of abdominal MRI can be the assessment of malignancies by difficulties to distinguish bowel from other organs or malignant masses. The use of oral contrast agents can reduce this problem. Properties of an ideal oral contrast agent are little or no absorption by the stomach or intestines, complete excretion, no motion or susceptibility artifacts, and uniform marking of the GI tract.
Gastrointestinal MRI contrast agents are divided in materials with bright appearance or dark appearance. The choice of a negative or a positive oral contrast agent depends on the specific problem or the pulse sequence.

See also Positive Oral Contrast Agents, Negative Oral Contrast Agents, Gastrointestinal Diamagnetic Contrast Agents, Gastrointestinal Paramagnetic Contrast Agents and Gastrointestinal Superparamagnetic Contrast Agents.

See also the related poll result: 'The development of contrast agents in MRI is'
spacer

• View the DATABASE results for 'Oral Contrast Agents' (17).Open this link in a new window

 
Further Reading:
  News & More:
Usefulness of MR Imaging for Diseases of the Small Intestine: Comparison with CT
2000   by www.ncbi.nlm.nih.gov    
Nottingham scientists exploit MRI technology to assist in the treatment of IBS
Thursday, 9 January 2014   by www.news-medical.net    
MRI Resources 
Pacemaker - Pediatric and Fetal MRI - Colonography - Jobs pool - Blood Flow Imaging - Used and Refurbished MRI Equipment
 
Positive Oral Contrast AgentsInfoSheet: - Contrast Agents - 
Intro, Overview, 
Characteristics, 
Types of, 
etc.MRI Resource Directory:
 - Contrast Agents -
 
Types of oral contrast agents with positive signal enhancement:
•
•
•
Combinations of these

Ideal oral contrast agents are immiscible with water, biologically inert, have a low viscosity and surface tension. Oral positive contrast agents may improve the separation of bowel loops, the detection of polyps in colon MRI or the assessment of inflammatory bowel in the small intestine. Several positive oral contrast agents are available and they are safe to use, for example gadolinium solution, ferric ammonium citrate, different oil emulsions and pediatric formula.
Unfavorably motion artifacts caused by respiration and peristalsis may be increased in MR imaging. In addition, the signal of the positive contrast medium may decrease caused by dilution in gastrointestinal (GI) secretions. With the use of contrast agents that are immiscible with water, no dilution and accompanying signal loss occur even when the contrast agent is in contact with the intraluminal contents of the GI tract. Another disadvantage may be residual substances in the bowel, resembling masses when enclosed by bright signal. In addition, positive contrast agents may have a similar signal as bright masses, which make their (e.g. lipoma) detection difficult.

See also Gastrointestinal Paramagnetic Contrast Agents, Combination Oral Contrast Agents, Gastrointestinal Diamagnetic Contrast Agents.
 
Images, Movies, Sliders:
 MR Colonography Gadolinium per Rectum  Open this link in a new window
      

Courtesy of  Robert R. Edelman
 
spacer

• View the DATABASE results for 'Positive Oral Contrast Agents' (6).Open this link in a new window

 
Further Reading:
  Basics:
Components of Oral Contrast Agent for Magnetic Resonance Imaging(.pdf)
   by www.ffcr.or.jp    
Hydro-MRI of the Small Bowel: Effect of Contrast Volume, Timing of Contrast Administration, and Data Acquisition on Bowel Distention
Sunday, 1 October 2006   by www.ajronline.org    
Searchterm 'Paramagnetic Contrast Agents' was also found in the following services: 
spacer
News  (2)  Resources  (1)  Forum  (1)  
 
Abdoscan®InfoSheet: - Contrast Agents - 
Intro, Overview, 
Characteristics, 
Types of, 
etc.MRI Resource Directory:
 - Contrast Agents -
 
This superparamagnetic oral contrast agent consists of large iron oxide particles, coated with insoluble material. Abdoscan® particles have a mean diameter no less than 300 nm. Gastrointestinal superparamagnetic contrast agents are used for negative bowel enhancement.

Abdoscan® was approved in Europe but was taken off the market in 2000, and all sales stopped by the end of 2002.
Drug Information and Specification
NAME OF COMPOUND
DEVELOPER
CENTRAL MOIETY
Fe2+/Fe3+
CONTRAST EFFECT
T2*, predominantly negative enhancement
PHARMACOKINETIC
Gastrointestinal
CONCENTRATION
23.4 Fe/200ml
PREPARATION
Dissolve
INDICATION
Bowel marking
DEVELOPMENT STAGE
Not FDA approved
PRESENTATION
Bags with powder
DO NOT RELY ON THE INFORMATION PROVIDED HERE, THEY ARE
NOT A SUBSTITUTE FOR THE ACCOMPANYING PACKAGE INSERT!
spacer

• View the DATABASE results for 'Abdoscan®' (2).Open this link in a new window

MRI Resources 
MRA - Process Analysis - Portals - Devices - Quality Advice - Bioinformatics
 
Adverse Reaction
 
Any abnormal reaction of a patient to an examination or procedure, like for example claustrophobia or side effects of MRI contrast agents.
A claustrophobic attack is MRI scanner dependent and more rare with an open MRI. An adverse reaction with magnetic resonance imaging contrast medium is very infrequent. In general, adverse reactions increase with the quantity of contrast media (usual dose of paramagnetic contrast agents is 0.1 mmol/kg) and also with the osmolarity of the compound.
Most frequently encountered adverse reactions are heat sensation, dizziness, nausea, hypotension due to vasodilatation, which can progress to hypotensive shock and anaphylactic reactions.
See also MRI Safety, Contrast Enhanced MRI, Breast MRI, and Cardiac MR imaging.
Radiology-tip.comradSafety of Contrast Agents,  Anaphylactoid Reaction
spacer
Medical-Ultrasound-Imaging.comUltrasound Contrast Agent Safety
spacer

• View the DATABASE results for 'Adverse Reaction' (8).Open this link in a new window

 
Further Reading:
  Basics:
Questions and Answers on Gadolinium-Based Contrast Agents
Friday, 9 January 2009   by www.fda.gov    
Contrast Agents: Safety Profile
   by www.clinical-mri.com    
  News & More:
CT contrast reaction raises MRI contrast risk
Tuesday, 22 February 2022   by www.sciencedaily.com    
MRI Resources 
Pediatric and Fetal MRI - MR Myelography - Online Books - Spine MRI - Contrast Enhanced MRI - Veterinary MRI
 
previous      6 - 10 (of 22)     next
Result Pages : [1]  [2 3 4 5]
 Random Page
 
Share This Page
FacebookTwitterLinkedIn

MR-TIP    
Community   
User
Pass
Forgot your UserID/Password ?    



Personalized protocols (age, gender, body habitus, etc.) lead to :
more automated planning 
improved patient comfort 
better diagnostics 
optimized image quality 
nothing 

Look
      Ups





MR-TIP.com uses cookies! By browsing MR-TIP.com, you agree to our use of cookies.

Magnetic Resonance - Technology Information Portal
Member of SoftWays' Medical Imaging Group - MR-TIP • Radiology-TIP • Medical-Ultrasound-Imaging • 
Copyright © 2003 - 2024 SoftWays. All rights reserved. [ 25 April 2024]
Terms of Use | Privacy Policy | Advertising
 [last update: 2024-02-26 03:41:00]