Noise Figure
 
A measure of the noise performance of an amplifier or chain of amplifiers such as a MR receiver. In MR systems the preamplifier should have a very low noise figure to prevent significant degradation of the signal to noise ratio of the MR signal. Noise figure is a ratio in dB's, and is given by: 20 log [Vo/(ViG)] where Vi is the input thermal noise voltage, Vo is the amplifier output noise level and G is the voltage gain of the amplifier (when the input and output impedance's of the amplifier are equal).
spacer
 
• Share the entry 'Noise Figure':  Facebook  Twitter  LinkedIn  
MRI Resources 
Functional MRI - Jobs - Services and Supplies - Colonography - Cochlear Implant - Chemistry
 
Preamplifier
 
A device that amplifies very low-level signals. A preamplifier is generally placed close to its signal source and has a very low noise figure as it is the principal determinant of electronic noise within the system. Preamplifiers used in NMR systems usually have a 50 ohm input impedance, and require a matching network to interface to the RF coil, although preamplifiers with high input impedance may be used with surface coils. Such devices typically use a field effect transistor (FET) as their input stage.
spacer

• View the DATABASE results for 'Preamplifier' (5).Open this link in a new window

MRI Resources 
Contrast Agents - Pathology - Universities - Contrast Enhanced MRI - Movies - Process Analysis
 
     1 - 2 (of 2)     
Result Pages : [1]
 Random Page
 
Share This Page
FacebookTwitterLinkedIn

MR-TIP    
Community   
User
Pass
Forgot your UserID/Password ?    



Personalized protocols (age, gender, body habitus, etc.) lead to :
more automated planning 
improved patient comfort 
better diagnostics 
optimized image quality 
nothing 

Look
      Ups





MR-TIP.com uses cookies! By browsing MR-TIP.com, you agree to our use of cookies.

Magnetic Resonance - Technology Information Portal
Member of SoftWays' Medical Imaging Group - MR-TIP • Radiology-TIP • Medical-Ultrasound-Imaging • 
Copyright © 2003 - 2024 SoftWays. All rights reserved. [ 29 March 2024]
Terms of Use | Privacy Policy | Advertising
 [last update: 2024-02-26 03:41:00]