Magnetic Resonance - Technology Information Portal Welcome to MRI Technology••
Info
  Sheets


Out-
      side
 



 
 'Multi Slice Off Resonance Fat Suppression' 
SEARCH FOR    
 
  2 3 5 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Result : Searchterm 'Multi Slice Off Resonance Fat Suppression' found in 1 term [] and 0 definition [], (+ 2 Boolean[] results
1 - 3 (of 3)     
Result Pages : [1]
MRI Resources 
Claustrophobia - Absorption and Emission - Collections - Mobile MRI - Cochlear Implant - Raman Spectroscopy
 
Multi Slice Off Resonance Fat SuppressionInfoSheet: - Sequences - 
Intro, 
Overview, 
Types of, 
etc.
 
(MSOFT) See Off Resonance and Fat Suppression.
spacer
 
• Share the entry 'Multi Slice Off Resonance Fat Suppression':  Facebook  Twitter  LinkedIn  
MRI Resources 
Pathology - Bioinformatics - Services and Supplies - Cardiovascular Imaging - Breast Implant - Open Directory Project
 
Aurora® 1.5T Dedicated Breast MRI SystemInfoSheet: - Devices -
Intro, 
Types of Magnets, 
Overview, 
etc.
 
From Aurora Imaging Technology, Inc.;
www.auroramri.com/mri/product/ The Aurora® 1.5T Dedicated Breast MRI System with Bilateral SpiralRODEO™ is the first and only FDA approved MRI device designed specifically for breast imaging. The Aurora System, which is already in clinical use at a growing number of leading breast care centers in the US, Europe, got in December 2006 also the approval from the State Food and Drug Administration of the People's Republic of China (SFDA).
'Some of the proprietary and distinguishing features of the Aurora System include: 1) an ellipsoid magnetic shim that provides coverage of both breasts, the chest wall and bilateral axillary lymph nodes; 2) a precision gradient coil with the high linearity required for high resolution spiral reconstruction;; 3) a patient-handling table that provides patient comfort and procedural utility; 4) a fully integrated Interventional System for MRI guided biopsy and localization; and 5) the user-friendly AuroraCAD™ computer-aided image display system designed to improve the accuracy and efficiency of diagnostic interpretations.'

Device Information and Specification
CLINICAL APPLICATION Breast MRI
CONFIGURATION Short bore compact
COILS Breast transmit receive (TR) coil
IMAGING MODES Bi-lateral RODEO fat suppression, high resolution Rotating Delivery of Excitation Offresonance Spiral, integrated targeting SW compatible with major MR guided intervention equipment.
TR 10 ms for gradient echo and less than 2,500 ms for T2 weighted spin echo
TE From 5 ms for RODEO Plus to over 80 ms, 120 ms for T2 sequences
SINGLE/MULTI SLICE Around 0.02 sec for a 256x256 image, 12.4 sec for a 512 x 512 x 32 multislice set
FOV 20 - 36 cm, max. elliptical 36 x 44 cm
MEASURING MATRIX 512 x 512
MAGNET TYPE Superconducting
BORE DIAMETER
or W x H
64 cm diameter (gantry)
MAGNET WEIGHT 8,500 lbs
H*W*D 240 x 188 x 163 cm
POWER REQUIREMENTS 150A/120V-208Y/3 Phase//60 Hz/5 Wire
COOLING SYSTEM Helium for magnet, distilled/de-ionized water for coil;
CRYOGEN USE Zero boil off rate
FIELD STRENGTH 1.5 T
spacer

• View the DATABASE results for 'Aurora® 1.5T Dedicated Breast MRI System' (2).Open this link in a new window


• View the NEWS results for 'Aurora® 1.5T Dedicated Breast MRI System' (3).Open this link in a new window.
 
Further Reading:
  Basics:
AURORA MRI SystemŽ Site Planning Guide
   by www.thorpeconstruction.com    
  News & More:
Aurora Imaging Technology Announces Approval in China
   by salesandmarketingnetwork.com    
Aurora Imaging Technology, Inc. Release: Results of a Multi-Center Trial Demonstrates Superior Diagnostic Performance of the AuroraŽ 1.5T Dedicated Breast MRI System Over Whole-Body Breast MRI
Monday, 1 October 2012   by www.biospace.com    
MRI Resources 
MRCP - Shielding - Pathology - MRI Reimbursement - Spectroscopy pool - Shoulder MRI
 
CHORUS 1.5T™InfoSheet: - Devices -
Intro, 
Types of Magnets, 
Overview, 
etc.MRI Resource Directory:
 - Devices -
 
www.isoltech.co.kr/english/product/default.htm

From ISOL Technology
'Next generation MRI system 1.5T CHORUS developed by ISOL Technology is optimized for both clinical diagnostic imaging and for research development.
CHORUS offers the complete range of feature oriented advanced imaging techniques- for both clinical routine and research. The compact short bore magnet, the patient friendly design and the gradient technology make the innovation to new degree of perfection in magnetic resonance.'


Device Information and Specification
CLINICAL APPLICATION Whole body
CONFIGURATION Short bore
SURFACE COILS Head, C-spine, L-spine, TMJ, Knee, Shoulder, General purpose, Phased Array System: 4 digital receiver channels (Up to 12 channels)
SPECTROSCOPY Optional
SYNCHRONIZATION ECG/peripheral: Optional/yes, respiratory gating
PULSE SEQUENCES Spin Echo, Gradient Echo, Fast Spin Echo, Inversion Recovery (STIR, Fluid Attenuated Inversion Recovery), FLASH, FISP, PSIF, Turbo Flash ( MPRAGE ),TOF MR Angiography, Standard echo planar imaging package (SE-EPI, GE-EPI), Optional: Advanced P.A. Imaging Package (up to 4 ch.), Advanced echo planar imaging package, Single Shot and Diffusion Weighted EPI, IR/FLAIR EPI
IMAGING MODES 2D/3D, Travelling Sat, Multi-Slab 3D, MTC and TONE Pulse Sequence, Fat/Water Suppression, Presaturation (up to 6 bands), Flow Compensation using GMR pulse, Multi-Slice, Multi-Group Imaging
SINGLE/MULTI SLICE Image reconstruction time (2562 ) : 0.02 s
FOV 40 cm
MAGNET TYPE Superconducting
BORE DIAMETER
or W x H
58 cm diameter (patient)
MAGNET WEIGHT 4050 kg
H*W*D 233 x 206 x 160 cm
COOLING SYSTEM TYPE Water-cooled coil and air-cooled amplifier
CRYOGEN USE 0.07 L/hr helium
FIELD STRENGTH 1.5 T
STRENGTH 20 mT/m (Upto 27 mT/m)
5-GAUSS FRINGE FIELD 2.5 m / 3.8 m
SHIMMING Passive and active


spacer

• View the DATABASE results for 'CHORUS 1.5T™' (2).Open this link in a new window

MRI Resources 
Brain MRI - - Pathology - Stimulator pool - Liver Imaging - Hospitals
 
     1 - 3 (of 3)     
Result Pages : [1]
 Random Page
 
Share This Page
FacebookTwitterLinkedIn

MR-TIP    
Community   
User
Pass
Forgot your UserID/Password ?  



Acoustic Noise Reduction (Silent, Quiet, etc.) :
cannot get better 
is in its first steps 
is done by earplugs, headphones 
must get better 
is bad, I miss something 
is unnecessary 

Look
      Ups





MR-TIP.com uses cookies! By browsing MR-TIP.com, you agree to our use of cookies.

Magnetic Resonance - Technology Information Portal
Member of SoftWays' Medical Imaging Group - MR-TIP • Radiology-TIP • US-TIP • 
Copyright © 2003 - 2018 SoftWays. All rights reserved. [ 25 May 2019]
Terms of Use | Privacy Policy | Advertising
 [last update: 2018-03-08 05:11:00]