Motion Probing Gradient
 
Many MR imaging techniques using Motion Probing Gradients (MPG's) such as Spin Echo (SE), Stimulated Echo (STE), Rapid Acquisition with Relaxation Enhancement (RARE), Turbo-SE, and SE-EPI (Echo Planar Imaging for Spin echo acquisition), Spiral imaging, and Projection reconstruction including PROPELLER are applicable to DWI. In diffusion weighted imaging, 2 MPG's are required. The MPG's are put symmetrically into both sides of a 180° or 90° RF pulse to change the direction of the magnetized spin in the X-Y plane for spin echo or stimulated echo acquisition.
spacer
 
Further Reading:
  Basics:
Diffusion Imaging: From Basic Physics to Practical Imaging
1999   by ej.rsna.org    
  News & More:
Motion Compensation in MR Imaging
   by ccn.ucla.edu    
Searchterm 'Gradient' was also found in the following services: 
spacer
Radiology  (1) Open this link in a new windowUltrasound  (3) Open this link in a new window
Phase Encoding Gradient
 
(Gφ) The phase encoding gradient is a magnetic field gradient that allows the encoding of the spatial signal location along a second dimension by different spin phases. The phase encoding gradient is applied after slice selection and excitation (before the frequency encoding gradient), orthogonally to the other two gradients. The spatial resolution is directly related to the number of phase encoding steps (gradients).
spacer

• View the DATABASE results for 'Phase Encoding Gradient' (18).Open this link in a new window

 
Further Reading:
  Basics:
RARE
Monday, 3 December 2012   by www2.warwick.ac.uk    
  News & More:
Principles of Magnetic Resonance Imaging
Friday, 21 December 2001   by www.mikepuddephat.com    
MRI Resources 
MRI Physics - Equipment - Guidance - Quality Advice - Anatomy - Services and Supplies
 
Shielded Gradient CoilsInfoSheet: - Coils - 
Intro, 
Overview, 
etc.MRI Resource Directory:
 - Coils -
 
Current-carrying gradient coils with reduced gradient fringe field inside of the magnet cryostat structures like cryoshields and He-vessel. The shielding can be accomplished by secondary actively driven coils or by passive screens, which are inductively coupled to the gradient coils. In both cases eddy currents outside of the gradient system will be reduced.

See also Eddy Currents.
spacer

• View the DATABASE results for 'Shielded Gradient Coils' (4).Open this link in a new window

 
Further Reading:
  Basics:
Faraday's Law
   by hyperphysics.phy-astr.gsu.edu    
Searchterm 'Gradient' was also found in the following services: 
spacer
News  (6)  Resources  (7)  Forum  (35)  
 
Turbo Gradient Spin EchoInfoSheet: - Sequences - 
Intro, 
Overview, 
Types of, 
etc.MRI Resource Directory:
 - Sequences -
 
(TGSE / TurboGSE) A sequence with a combination of Gradient and Spin Echo Imaging. Additional gradient echoes are generated before and after each spin echo. The spin echoes are allocated to the center of the raw data matrix to give pure T2 contrast. The gradient echoes primarily determine the image resolution. If multiple image lines are obtained during a single echo, the imaging pulse sequence type is a TGSE pulse sequence. This sequence is very fast, fat is darker and more sensitive to susceptibility effects. Also called GRASE.
spacer
Searchterm 'Gradient' was also found in the following services: 
spacer
Radiology  (1) Open this link in a new windowUltrasound  (3) Open this link in a new window
Gradient Echo Multi SliceInfoSheet: - Sequences - 
Intro, 
Overview, 
Types of, 
etc.
 
(GEMS) This pulse sequence uses a changeable flip angle instead of a 90° pulse and a gradient instead of a RF pulse to rephase the FID.
T2*, T1 weighted and proton density images can be acquired. The flip angle in combination with the TR determines the T1 weighting and the TE controls the amount of dephasing. To minimize T2* the echo time should be short.

See also Gradient Echo Sequence.
spacer
MRI Resources 
Devices - Mobile MRI - Process Analysis - - MRI Training Courses - Safety Training
 
previous      26 - 30 (of 311)     next
Result Pages : [1 2 3 4 5 6 7 8 9 10 11 12]  [13 14 15 16 17 18 19 20 ... ]
 Random Page
 
Share This Page
FacebookTwitterLinkedIn

MR-TIP    
Community   
User
Pass
Forgot your UserID/Password ?    



How AI will impact MRI :
only diagnostics 
saving time 
reducing cost 
makes planning obsolete 
reduce human knowledge 
not at all 

Look
      Ups





MR-TIP.com uses cookies! By browsing MR-TIP.com, you agree to our use of cookies.

Magnetic Resonance - Technology Information Portal
Member of SoftWays' Medical Imaging Group - MR-TIP • Radiology-TIP • Medical-Ultrasound-Imaging • 
Copyright © 2003 - 2024 SoftWays. All rights reserved. [ 25 April 2024]
Terms of Use | Privacy Policy | Advertising
 [last update: 2024-02-26 03:41:00]