Magnetic Resonance - Technology Information Portal Welcome to MRI Technology
Info
  Sheets

Out-
      side
 



 
 'Gadovist%C2%AE' 
SEARCH FOR    
 
  2 3 5 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Result : Searchterm 'Gadovist®' found in 1 term [] and 2 definitions []
1 - 3 (of 3)     
Result Pages : [1]
MRI Resources 
Resources - Guidance - Devices - Quality Advice - Mass Spectrometry - Sequences
 
Gadovist®InfoSheet: - Contrast Agents - 
Intro, Overview, 
Characteristics, 
Types of, 
etc.MRI Resource Directory:
 - Contrast Agents -
 
Gadovist® is an extracellular, neutral macrocyclic (gadolinium (Gd) complex) MRI contrast agents for central nervous system indications, particularly suited for studies in which high doses are required or advantageous. Gadovist® (also Gadograf) was available in two concentrations, currently only Gadovist® 1.0 is marketed.
The product was approved in Switzerland in 1999 and in Germany in 2000. Gadovist® 1.0 is in USA currently in the drug development and approval process, particularly for magnetic resonance angiography.

WARNING: NEPHROGENIC SYSTEMIC FIBROSIS Gadolinium-based contrast agents increase the risk for nephrogenic systemic fibrosis (NSF) in patients with acute or chronic severe renal insufficiency (glomerular filtration rate less than 30 mL/min/1.73m2), or acute renal insufficiency of any severity due to the hepato-renal syndrome or in the perioperative liver transplantation period.

See also Paramagnetic Contrast Agents and Gadobutrol.
Drug Information and Specification
NAME OF COMPOUND
Gadobutrol, Gd-BT-DO3A
CENTRAL MOIETY
Gd2+
CONTRAST EFFECT
T1, Predominantly positive enhancement
r1=3.6, B0=1.0 T
PHARMACOKINETIC
Intravascular, extracellular, renal excretion
OSMOLALITY
557 and 1603 mosm/kgH2O
CONCENTRATION
1 mol/L
DOSAGE
0.1mmol/kg
PREPARATION
Finished product
INDICATION
Central nervous system / whole body
DEVELOPMENT STAGE
For sale / submit for approval
DISTRIBUTOR
See below
PRESENTATION
Vials of 15, 30 mL
DO NOT RELY ON THE INFORMATION PROVIDED HERE, THEY ARE
NOT A SUBSTITUTE FOR THE ACCOMPANYING PACKAGE INSERT!
Distribution Information
TERRITORY
TRADE NAME
DEVELOPMENT
STAGE
DISTRIBUTOR
USA
Gadovist®
Submit for approval
Japan
Gadovist®
EU
Gadovist®
for sale
Australia
Gadovist®
for sale
spacer
 
• Share the entry 'Gadovist®':  Facebook  Twitter  LinkedIn  
 
Further Reading:
  Basics:
Important Drug Warning for Gadolinium-Based Contrast Agents
Wednesday, 12 September 2007   by www.ismrm.org    
Gadograf, Gadovist
Friday, 13 April 2007   by www.ema.europa.eu    
  News & More:
EMA's final opinion confirms restrictions on use of linear gadolinium agents in body scans
Friday, 21 July 2017   by www.ema.europa.eu    
FDA Drug Safety Communication: FDA warns that gadolinium-based contrast agents (GBCAs) are retained in the body; requires new class warnings
Tuesday, 19 December 2017   by www.fda.gov    
FDA approves Bayer's Gadavist® (gadobutrol) injection as the first magnetic resonance contrast agent for pediatric patients less than 2 years of age
Monday, 5 January 2015   by www.prnewswire.com    
New data presented at RSNA on use of Bayer's Gadavist® (gadobutrol) injection in children less than 2 years of age
Wednesday, 3 December 2014   by www.prnewswire.com    
MRI Resources 
Nerve Stimulator - Coils - Diffusion Weighted Imaging - Jobs pool - Health - Brain MRI
 
Bayer Schering Pharma AGMRI Resource Directory:
 - Manufacturers -
 
www.bayerscheringpharma.de/scripts/pages/en/index.php The Germany-based pharmaceutical company is the result of the take-over of Schering AG by Bayer AG in 2006. The Bayer Schering Pharma AG is part of the Bayer HealthCare AG, which represents the pharmaceutical part of the Bayer Group. Activities of the Bayer Schering Pharma AG are Diagnostic Imaging, Hematology and Cardiology, Oncology, Primary Care, Specialized Therapeutics and Women's Healthcare. The diagnostic imaging part's contrast agents for MRI, x-ray and computed tomography are 'world-market leaders'.

MRI Contrast Agents:
Contact Information
MAIL
Bayer Schering Pharma AG
51368 Leverkusen
GERMANY
PHONE
+49-30-46-81-2431
FAX
+49-30-46-81-8195
spacer

• View the DATABASE results for 'Bayer Schering Pharma AG' (22).Open this link in a new window


• View the NEWS results for 'Bayer Schering Pharma AG' (25).Open this link in a new window.
 
Further Reading:
  News & More:
Drastic market changes with MRI contrast media and PET radiopharmaceuticals emerging as most promising segments
Thursday, 21 October 2004   by www.news-medical.net    
Epix Pharmaceuticals to shut down
Tuesday, 21 July 2009   by boston.bizjournals.com    
MRI Resources 
Bioinformatics - RIS - Homepages - MRI Technician and Technologist Jobs - Mobile MRI Rental - MRI Technician and Technologist Career
 
Paramagnetic Contrast AgentsInfoSheet: - Contrast Agents - 
Intro, Overview, 
Characteristics, 
Types of, 
etc.MRI Resource Directory:
 - Contrast Agents -
 
Magnetic relaxation in tissues can be enhanced using contrast agents. The most commonly used for MRI are the paramagnetic contrast agents, which have their strongest effect on the T1, by increasing T1 signal intensity in tissues where they have accumulated.
MRI collects signal from the water protons, but the presence of these contrast agents enhances the relaxation of water protons in their vicinity. Paramagnetic contrast agents contain magnetic centers that create magnetic fields approximately one thousand times stronger than those corresponding to water protons. These magnetic centers interact with water protons in exactly the same way as the neighboring protons, but with much stronger magnetic fields, and therefore, have a much greater impact on relaxation rates, particularly on T1. In MRI, contrast agents are routinely injected intravenously to help identify areas of hypervascularity, as in malignant tumors.

See also Contrast Agents, Gadovist®, MultiHance®, Omniscan®, OptiMARK®.

See also the related poll result: 'The development of contrast agents in MRI is'
 
Images, Movies, Sliders:
 MRI Upper Abdomen T1 with Contrast  Open this link in a new window
    
 MRI Orbita T1  Open this link in a new window
 MRI Orbita T1 with Contrast  Open this link in a new window
    
 
spacer

• View the DATABASE results for 'Paramagnetic Contrast Agents' (22).Open this link in a new window


• View the NEWS results for 'Paramagnetic Contrast Agents' (1).Open this link in a new window.
 
Further Reading:
  Basics:
LEARNING CENTER FOR PARAMAGNETISM
2003   by www.naturesalternatives.com    
Contrast Agents: Safety Profile
   by www.clinical-mri.com    
Contrast Agents in Magnetic Resonance Imaging
1997
  News & More:
Gadolinium-containing contrast agents: removal of Omniscan and iv Magnevist, restrictions to the use of other linear agents
Friday, 5 January 2018   by www.gov.uk    
EMA's final opinion confirms restrictions on use of linear gadolinium agents in body scans
Friday, 21 July 2017   by www.ema.europa.eu    
FDA Drug Safety Communication: FDA warns that gadolinium-based contrast agents (GBCAs) are retained in the body; requires new class warnings
Tuesday, 19 December 2017   by www.fda.gov    
RSNA Statement on Gadolinium-Based MR Contrast Agents
Thursday, 1 February 2018   by www.rsna.org    
Contrast MRIs cause claims, concern, over residual metal in brain
Tuesday, 8 December 2015   by www.afr.com    
MRI Resources 
MRA - IR - Services and Supplies - Anatomy - Directories - NMR
 
     1 - 3 (of 3)     
Result Pages : [1]
 Random Page
 
Share This Page
FacebookTwitterLinkedIn

MR-TIP    
Community   
User
Pass
Forgot your UserID/Password ?    



Next big thing in MRI will be :
AI 
remote operator 
personalized protocols 
helium-free 
molecular MRI 
portable MRI 

Look
      Ups





MR-TIP.com uses cookies! By browsing MR-TIP.com, you agree to our use of cookies.

Magnetic Resonance - Technology Information Portal
Member of SoftWays' Medical Imaging Group - MR-TIP • Radiology-TIP • Medical-Ultrasound-Imaging • 
Copyright © 2003 - 2024 SoftWays. All rights reserved. [ 16 April 2024]
Terms of Use | Privacy Policy | Advertising
 [last update: 2024-02-26 03:41:00]