Magnetic Resonance - Technology Information Portal Welcome to MRI Technology
Info
  Sheets

Out-
      side
 



 
 'Esaote S.p.A.' 
SEARCH FOR    
 
  2 3 5 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Result : Searchterm 'Esaote S.p.A.' found in 1 term [] and 5 definitions []
1 - 5 (of 6)     next
Result Pages : [1]  [2]
MRI Resources 
MR Guided Interventions - Raman Spectroscopy - - Resources - Absorption and Emission - Portals
 
Esaote S.p.A.MRI Resource Directory:
 - Manufacturers -
 
www.esaote.com The Esaote Group, founded in the 1980's, is a global leader in research, production, and marketing of medical diagnostic equipment and related services. Esaote offers integrated diagnostic solutions for ultrasound electromedical diagnostic systems, and MRI. The Esaote MR equipment is dedicated for specific clinical applications, as distinguished from conventional whole body MRI systems. This MRI product family is based on a unique, proprietary technology developed specifically for musculoskeletal imaging.
The Italian based company is a member of the Bracco Group.
Esaote North America is the exclusive U.S. distributor of MRI devices manufactured by Esaote.

MRI Scanners:

0.2T to 0.31T:
Vet-MR (Based on the E Scan XQ, dedicated to the veterinarian practice.)
Contact Information
MAIL
ESAOTE S.p.A. MRI DIvision
Via Siffredi, 58
16153 Genova
Italy
PHONE
+39-010-6547.380
FAX
+39-010-6547.241
CONTACT INFO PAGE
spacer
 
• Share the entry 'Esaote S.p.A.':  Facebook  Twitter  LinkedIn  

• View the NEWS results for 'Esaote S.p.A.' (1).Open this link in a new window.
 
Further Reading:
  Basics:
E-Scan, 510(k) Summary(.pdf)
Saturday, 15 May 2004   by www.accessdata.fda.gov    
  News & More:
Esaote Obtains EC MDR Certification for the New Magnifico Open Total-body Magnetic Resonance System
Sunday, 5 December 2021   by www.itnonline.com    
Global Magnetic Resonance Imaging Systems Market Data Analysis 2019-2025 Aurora Imaging Technology, Esaote, Fonar Corporation
Wednesday, 8 January 2020   by citiblognews.com    
Searchterm 'Esaote S.p.A.' was also found in the following service: 
spacer
Ultrasound  (15) Open this link in a new window
C-SCAN™InfoSheet: - Devices -
Intro, 
Types of Magnets, 
Overview, 
etc.MRI Resource Directory:
 - Devices -
 
www.gehealthcare.com/usen/mr/cscan/index.html Manufactured by Esaote S.p.A.; compact in-office MRI system, fits in a 90 ft2 (8.4 m2) space and requires no shielding or special power. This low field MRI magnet is optimized for orthopedic use and imaging of the extremities.
The C-SCAN™ is developed from the ARTOSCAN™ - M with a new computer platform, and is also known as Artoscan C.
Esaote North America and Hologic Inc. are the U.S. distributors of this MRI device.
Device Information and Specification
CLINICAL APPLICATION
Dedicated extremity
CONFIGURATION
Closed
Linear and dual phased array, knee, ankle, wrist (6 total) coils
PULSE SEQUENCES
SE, GE, IR, STIR, FSE, 3D CE, GE-STIR, 3D GE, ME, TME, HSE
IMAGING MODES
Single, multislice, volume study, fast scan, multi slab
TR
12 - 5,000 msec
TE
5 - 220 msec
SINGLE SLICE
0.8 sec/image
MULTISLICE
0.8 sec/image
FOV
10 - 20 cm
2D: 2 mm - 10 mm;
3D: 0.6 mm - 10 mm
512 x 512
MEASURING MATRIX
256 x 256 maximum
PIXEL INTENSITY
4,096 gray lvls, 256 lvls in 3D
MAGNET TYPE
Permanent
BORE DIAMETER
or W x H
33.6 x 16 cm
MAGNET WEIGHT
960 kg
H*W*D
124 x 76 x 60 cm
POWER REQUIREMENTS
100/110/200/220/230/240
STRENGTH
10 mT/m
5-GAUSS FRINGE FIELD, radial/axial
28 cm/60 cm
Passive
spacer

• View the DATABASE results for 'C-SCAN™' (4).Open this link in a new window

MRI Resources 
Abdominal Imaging - Databases - Examinations - Most Wanted - Breast MRI - Knee MRI
 
G-SCANInfoSheet: - Devices -
Intro, 
Types of Magnets, 
Overview, 
etc.MRI Resource Directory:
 - Devices -
 
www.esaote.de/04_kernspin/gscan/gscan.htm From Esaote S.p.A.; Esaote introduced the new G-SCAN at the RSNA in Dec. 2004. The G-SCAN covers almost all musculoskeletal applications including the spine. The tilting gantry is designed for scanning in weight-bearing positions. This unique MRI scanner is developed in line with the Esaote philosophy of creating high quality MRI systems that are easy to install and that have a low breakeven point.
Device Information and Specification
CLINICAL APPLICATION
CONFIGURATION
Spine, extremity, shoulder, flex coil, knee dual phased array, ankle//foot dual phased array, hand//wrist dual phased array
PULSE SEQUENCES
SE, GE, IR, STIR, TSE, 3D CE, GE-STIR, 3D GE, ME, TME, HSE
IMAGING MODES
Single, multislice, volume study, fast scan, multi slab, cine
FOV
100 up to 350 mm, 25 mm displayed
512 x 512
MEASURING MATRIX
256 x 256 maximum
MAGNET TYPE
Permanent
BORE DIAMETER
or W x H
33 cm H, open
POWER REQUIREMENTS
100/110/200/220/230/240 V
STRENGTH
25 mT/m
5-GAUSS FRINGE FIELD
180 cm
Passive
spacer

• View the DATABASE results for 'G-SCAN' (3).Open this link in a new window

MRI Resources 
MRI Training Courses - Knee MRI - Portals - Education - Stent - MRCP
 
GE LunarMRI Resource Directory:
 - Manufacturers -
 
www.gehealthcare.com [This entry is marked for removal.]

General Electric (GE) agreed to buy diagnostic systems maker Lunar Corp. for $150m. in March 2000. In 2004/05 it seems that the integration process into GE Healthcare has been completed. (GE Medical Systems and Amersham announced in April 2004 the completion of a share exchange acquisition of Amersham Health by GE. The result of this acquisition is the new GE Healthcare, based in the UK, totally owned by General Electric (GE).

The U.S.-based company developed bone densitometers and scanning machines that measure bone density as a way of diagnosing osteoporosis and other metabolic bone diseases. GE Lunar marketed these products worldwide.
GE Lunar announced a distribution agreement with MagneVu for domestic sales of the MagneVu 1000, a portable MRI device for orthopedic use, under the trade name Applause™.
GE Lunar was the exclusive U.S. distributor of MR-devices manufactured by Esaote S.p.A. These compact in-office MRI™ machines are designed to fit all practice sizes in orthopedic imaging and complete the range of diagnostic imaging systems.
spacer

• View the DATABASE results for 'GE Lunar' (2).Open this link in a new window

 
Further Reading:
  News & More:
Portable MR system aids diagnosis of rheumatic diseases
Sunday, 12 January 2003   by www.diagnosticimaging.com    
Searchterm 'Esaote S.p.A.' was also found in the following service: 
spacer
Ultrasound  (15) Open this link in a new window
Opera (E-SCAN™ XQ)InfoSheet: - Devices -
Intro, 
Types of Magnets, 
Overview, 
etc.MRI Resource Directory:
 - Devices -
 
www.esaote.com/products/MRI/eScanXQ/products1.htm Manufactured by Esaote S.p.A.;
a low field open MRI scanner with permanent magnet for orthopedic use. The outstanding feature of this MRI system is a patient friendly design with 24 cm diameter, which allows the imaging of extremities and small body parts like shoulder MRI. The power consumption is around 1.3 kW and the needed minimum floor space is an area of 16 sq m.
At RSNA 2006 Hologic Inc. introduced a new dedicated extremity MRI scanner, the Opera. Manufactured by Esaote is the Opera a redesign of Esaote's 0.2 Tesla E-Scan XQ platform, which now enables complete imaging of all extremities, including hip and shoulder applications. 'Real-time positioning' reportedly speeds patient setup and reduces exam times.
Esaote North America and Hologic Inc are the U.S. distributors of this MRI device.
Device Information and Specification
CLINICAL APPLICATION
Dedicated extremity
CONFIGURATION
Extremity, shoulder (2), flex coil, knee dual phased array, ankle//foot dual phased array, hand//wrist dual phased array coil
PULSE SEQUENCES
SE, GE, IR, STIR, FSE, 3D CE, GE-STIR, 3D GE, ME, TME, HSE
IMAGING MODES
Single, multislice, volume study, fast scan, multi slab
TR
10 - 5000 msec
TE
6 - 110 msec
SINGLE SLICE
0.6 sec/image
MULTISLICE
0.6 sec/image
17 cm
2D: 2 mm - 10 mm;
3D: 0.6 mm - 10 mm
MEASURING MATRIX
256 x 256 maximum
PIXEL INTENSITY
4096 gray lvls, 256 lvls in 3D
MAGNET TYPE
Permanent
24 cm H, open
MAGNET WEIGHT
2250 kg, 4960 lbs
H*W*D
79 x 65 x 85 cm
POWER REQUIREMENTS
2,0 kW; 110/220 V single phase
STRENGTH
20 mT/m
5-GAUSS FRINGE FIELD, radial/axial
150 cm/130 cm
Passive
spacer

• View the DATABASE results for 'Opera (E-SCAN™ XQ)' (2).Open this link in a new window

 
Further Reading:
  News & More:
E-Scan, 510(k) Summary(.pdf)
Saturday, 15 May 2004   by www.accessdata.fda.gov    
MRI Resources 
Distributors - Cochlear Implant - Supplies - Non-English - DICOM - Contrast Agents
 
     1 - 5 (of 6)     next
Result Pages : [1]  [2]
 Random Page
 
Share This Page
FacebookTwitterLinkedIn

MR-TIP    
Community   
User
Pass
Forgot your UserID/Password ?    



MRI is trending to low field magnets :
reduced costs will lead to this change 
AI will close the gap to high field 
only in remote areas 
is only temporary 
never 

Look
      Ups





MR-TIP.com uses cookies! By browsing MR-TIP.com, you agree to our use of cookies.

Magnetic Resonance - Technology Information Portal
Member of SoftWays' Medical Imaging Group - MR-TIP • Radiology-TIP • Medical-Ultrasound-Imaging • 
Copyright © 2003 - 2024 SoftWays. All rights reserved. [ 28 March 2024]
Terms of Use | Privacy Policy | Advertising
 [last update: 2024-02-26 03:41:00]