Magnetic Resonance - Technology Information Portal Welcome to MRI Technology••
Info
  Sheets


Out-
      side
 



 
 'Device Information' 
SEARCH FOR    
 
  2 3 5 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Result : Searchterm 'Device Information' found in 0 term [] and 70 definitions []
previous     56 - 60 (of 70)     next
Result Pages : [1 2 3 4 5 6 7 8 9 10 11 12 13 14]
Searchterm 'Device Information' was also found in the following services: 
spacer
News  (2)  Resources  (4)  
 
Signa HDx 1.5T™InfoSheet: - Devices -
Intro, 
Types of Magnets, 
Overview, 
etc.
 
From GE Healthcare;
www.vitalcom.com/euen/mri/products/signa-hdx-15t/index.html The GE Signa HDx MRI system is a whole body magnetic resonance scanner designed to support high resolution, high signal to noise ratio, and short scan times.
The 1.5T Signa HDx MR Systems is a modification of the currently marketed GE 1.5T machines, with the main difference being the change to the receive chain architecture that includes a thirty two independent receive channels, and allows for future expansion in 16 channel increments. The overall system has been improved with a simplified user interface and a single 23" liquid crystal display, improved multi channel surface coil connectivity, and an improved image reconstruction architecture known as the Volume Recon Engine (VRE).

Device Information and Specification
CLINICAL APPLICATION Whole body
CONFIGURATION Compact short bore
SURFACE COILS Head and body coil, abdomen, spine, breast, knee, shoulder, cardiac imaging coils
SPECTROSCOPY Possible
SYNCHRONIZATION ECG/peripheral, respiratory gating, (SmartPrep, SmartStep)
PULSE SEQUENCES Standard: SE, IR, 2D/3D GRE and SPGR, Angiography: 2D/3D TOF, 2D/3D Phase Contrast; 2D/3D FSE, 2D/3D FGRE and FSPGR, SSFP, FLAIR, EPI, optional: 2D/3D Fiesta, FGRET, Spiral, Tensor,
IMAGING MODES 2D single slice, multi slice, and 3D volume images, multi slab, cine
FOV 1 cm to 48 cm continuous
SLICE THICKNESS 2D 0.7 mm to 20 mm; 3D 0.1 mm to 5 mm
DISPLAY MATRIX 1028 x 1024
MEASURING MATRIX 128x512 steps 32 phase encode
PIXEL INTENSITY 256 gray levels
MAGNET TYPE Superconducting
POWER REQUIREMENTS 480 or 380/415
COOLING SYSTEM TYPE Closed-loop water-cooled gradient
CRYOGEN USE, L/hr less than 0.03 L/hr liquid helium
FIELD STRENGTH 1.5 T
spacer
MRI Resources 
Software - Jobs pool - Pacemaker - Used and Refurbished MRI Equipment - Bioinformatics - Distributors
 
Signa HDx 3.0T™InfoSheet: - Devices -
Intro, 
Types of Magnets, 
Overview, 
etc.
 
From GE Healthcare;
gehealthcare.com/euen/mri/products/signa-hdx-3t/index.html The Signa HDx MRI system is GE's leading edge whole body magnetic resonance scanner designed to support high resolution, high signal to noise ratio, and short scan times.
Signa HDx 3.0T offers new technologies like ultra-fast image reconstruction through the new XVRE recon engine, advancements in parallel imaging algorithms and the broadest range of premium applications. The HD applications, PROPELLER (high-quality brain imaging extremely resistant to motion artifacts), TRICKS (contrast-enhanced angiographic vascular lower leg imaging), VIBRANT (for breast MRI), LAVA (high resolution liver imaging with shorter breath holds and better organ coverage) and MR Echo (high-definition cardiac images in real time) offer unique capabilities.

Device Information and Specification
CLINICAL APPLICATION Whole body
CONFIGURATION Compact short bore
SURFACE COILS Head and body coil, T/R quadrature head;; optional coils e.g., T/R phased array extremity abdomen, spine, breast, knee, shoulder, cardiac imaging coils
SPECTROSCOPY Single voxel and 2D CSI proton
SYNCHRONIZATION ECG/peripheral, respiratory gating
PULSE SEQUENCES SE, IR, 2D/3D GRE, RF-spoiled GRE, 2DFGRE, 2DFSPGR, 3DFGRE, 3DFSPGR, 3DTOFGRE, 3DFSPGR, 2DFSE, 2DFSE-XL, 2DFSE-IR, T1-FLAIR, SSFSE, EPI, DW-EPI, BRAVO, Angiography: 2D/3D TOF, 2D/3D phase contrast vascular
IMAGING MODES Single, multislice, volume study, fast scan, multi slab, cine, localizer
FOV 1 cm to 40 cm continuous
SLICE THICKNESS 2D 0.5 mm; 3D 0.1 mm
DISPLAY MATRIX 1024 x 1024
PIXEL INTENSITY 256 gray levels
MAGNET TYPE Superconducting
BORE DIAMETER
or W x H
60 cm
MAGNET WEIGHT 12000 kg
H*W*D 240 x 2216,6 x 201,6 cm
POWER REQUIREMENTS 480 or 380/415, 3 phase ||
COOLING SYSTEM TYPE Closed-loop water-cooled grad.
CRYOGEN USE 0.03 L/hr helium
FIELD STRENGTH 3 tesla (3T)
STRENGTH 23 - 50 mT/m
SLEW RATE 80 - 150 mT/m/ms
5-GAUSS FRINGE FIELD 2.8 m / 5.0 m
SHIMMING second and high order
spacer
MRI Resources 
Pregnancy - Breast MRI - MRCP - Equipment - Journals - PACS
 
Signa Infinity 1.0T™InfoSheet: - Devices -
Intro, 
Types of Magnets, 
Overview, 
etc.MRI Resource Directory:
 - Devices -
 
From GE Healthcare;
www.gehealthcare.com/usen/mr/index.html the Signa Infinity Magnetic Resonance system is a short bore, high performance, whole-body imaging system operating at 1.0 Tesla. The system can image in any orthogonal or oblique plane (including single and double axis oblique), using a wide variety of pulse sequences.

Device Information and Specification
CLINICAL APPLICATION Whole body
CONFIGURATION Short bore
SURFACE COILS Head and body coil standard; all other coils optional; open architecture makes system compatible with a wide selection of coils
SPECTROSCOPY No
SYNCHRONIZATION ECG/peripheral, respiratory gating
PULSE SEQUENCES Standard: SE, IR, 2D/3D GRE and SPGR, Angiography;; 2D/3D TOF, 2D/3D Phase Contrast;; 2D/3D FSE, 2D/3D FGRE and FSPGR, SSFP, FLAIR, optional: EPI, 2D/3D Fiesta, FGRET, Spiral
IMAGING MODES Localizer, single slice, multislice, volume, fast, POMP, multi slab, cine
TR 4.4 msec to 12000 msec in increments of 1 msec
TE 1.0 to 2000 msec; increments of 1 msec
SINGLE/MULTI SLICE Simultaneous scan and reconstruction;; up to 100 images/second with Reflex 100
FOV 1 cm to 48 cm continuous
SLICE THICKNESS 2D 0.7 mm to 20 mm; 3D 0.1 mm to 5 mm
DISPLAY MATRIX 1280 x 1024
MEASURING MATRIX 128x512 steps 32 phase encode
PIXEL INTENSITY 256 gray levels
SPATIAL RESOLUTION 0.08 mm; 0.02 mm optional
MAGNET TYPE Superconducting
BORE DIAMETER 60 cm
MAGNET WEIGHT 3613 kg
H*W*D 172 x 208 x 216 cm
POWER REQUIREMENTS 480 or 380/415 V
COOLING SYSTEM TYPE Closed-loop water-cooled gradient
CRYOGEN USE Less than 0.03 L/hr liquid helium
FIELD STRENGTH 1.0 T
STRENGTH SmartSpeed 23 mT/m, HiSpeed Plus 33 mT/m
5-GAUSS FRINGE FIELD 4.0 m x 2.8 m axial x radial
SHIMMING Active
spacer

• View the DATABASE results for 'Signa Infinity 1.0T™' (2).Open this link in a new window

Searchterm 'Device Information' was also found in the following services: 
spacer
News  (2)  Resources  (4)  
 
Signa Infinity 1.5T™ TwinSpeed with ExciteInfoSheet: - Devices -
Intro, 
Types of Magnets, 
Overview, 
etc.MRI Resource Directory:
 - Devices -
 
From GE Healthcare;
www.gehealthcare.com/usen/mr/s_excite15/index.html three dedicated MRI systems - a neuro imager, a cardiovascular system, and a whole body scanner - all in one system.
Device Information and Specification
CLINICAL APPLICATION Whole body
CONFIGURATION Short bore
SURFACE COILS Head and body coil standard; all other coils optional; open architecture makes system compatible with a wide selection of coils
SPECTROSCOPY Optional 2D/3D brain and prostate
SYNCHRONIZATION ECG/peripheral, respiratory gating
PULSE SEQUENCES Standard: SE, IR, 2D/3D GRE and SPGR, Angiography: 2D/3D TOF, 2D/3D Phase Contrast;; 2D/3D FSE, 2D/3D FGRE and FSPGR, SSFP, FLAIR, EPI, optional: 2D/3D Fiesta, FGRET, Spiral, Tensor
IMAGING MODES Localizer, single slice, multislice, volume, fast, POMP, multi slab, cine
TR 1.2 to 12000 msec in increments of 1 msec
TE 0.4 to 2000 msec in increments of 1 msec
SINGLE/MULTI SLICE Simultaneous scan and reconstruction;; up to 200 or 400 images per second
FOV 1 cm to 48 cm continuous
SLICE THICKNESS 2D 0.7 mm to 20 mm; 3D 0.1 mm to 5 mm
DISPLAY MATRIX 1280 x 1024
MEASURING MATRIX 128x512 steps 32 phase encode
PIXEL INTENSITY 256 gray levels
SPATIAL RESOLUTION 0.02mm
MAGNET TYPE Superconducting
BORE DIAMETER
or W x H
60 cm
MAGNET WEIGHT 3863 kg
H*W*D 172 x 208 x 216 cm
POWER REQUIREMENTS 480 or 380/415
COOLING SYSTEM TYPE Closed-loop water-cooled gradient
CRYOGEN USE Less than 0.03 L/hr liquid He
FIELD STRENGTH 1.5 T
STRENGTH Zoom 40 mT/m, whole body 23 mT/m
5-GAUSS FRINGE FIELD 4.0 m x 2.8 m axial x radial
SHIMMING Active
spacer

• View the DATABASE results for 'Signa Infinity 1.5T™ TwinSpeed with Excite' (2).Open this link in a new window

 
Further Reading:
  News & More:
Twin Gradient Technology - Potential Advantages For Diffusion Weighted MRI(.pdf)
   by www.paulrharvey.co.uk    
MRI Resources 
Shielding - MRI Training Courses - Services and Supplies - Devices - Safety pool - MRA
 
Signa Infinity 1.5T™ with ExciteInfoSheet: - Devices -
Intro, 
Types of Magnets, 
Overview, 
etc.MRI Resource Directory:
 - Devices -
 
From GE Healthcare;
www.gehealthcare.com/usen/mr/s_excite15/index.html 'EXCITE technology has the potential to open the door to new imaging techniques and clinical applications, leaping beyond conventional two and three-dimensional MRI to true 4D imaging that will improve the diagnosis of disease throughout the human body from head to foot.' Robert R. Edelman, M.D., Professor of Radiology at Northwestern University Medical School and Chairman, Department of Radiology, at Evanston Northwestern Healthcare.

Device Information and Specification
CLINICAL APPLICATION Whole body
CONFIGURATION Short bore
SURFACE COILS Head and body coil standard; all other coils optional; open architecture makes system compatible with a wide selection of coils
SPECTROSCOPY Optional 2D/3D brain and prostate
SYNCHRONIZATION ECG/peripheral, respiratory gating, (SmartPrep, SmartStep)
PULSE SEQUENCES Standard: SE, IR, 2D/3D GRE and SPGR, Angiography: 2D/3D TOF, 2D/3D Phase Contrast;; 2D/3D FSE, 2D/3D FGRE and FSPGR, SSFP, FLAIR, EPI, optional: 2D/3D Fiesta, FGRET, Spiral, Tensor
IMAGING MODES Localizer, single slice, multislice, volume, fast, POMP, multi slab, cine
TR 1.3 to 12000 msec in increments of 1 msec
TE 0.4 to 2000 msec in increments of 1 msec
SINGLE/MULTI SLICE Simultaneous scan and reconstruction;; up to 200 or 400 images per second
FOV 1 cm to 48 cm continuous
SLICE THICKNESS 2D 0.7 mm to 20 mm; 3D 0.1 mm to 5 mm
DISPLAY MATRIX 1028 x 1024
MEASURING MATRIX 128x512 steps 32 phase encode
PIXEL INTENSITY 256 gray levels
SPATIAL RESOLUTION 0.08 mm; 0.02 mm optional
MAGNET TYPE Superconducting
BORE DIAMETER 60 cm
MAGNET WEIGHT 3863 kg
H*W*D 172 x 208 x 216 cm
POWER REQUIREMENTS 480 or 380/415
COOLING SYSTEM TYPE Closed-loop water-cooled gradient
CRYOGEN USE, L/hr less than 0.03 L/hr liquid helium
FIELD STRENGTH 1.5 T
STRENGTH SmartSpeed 23 mT/m, HiSpeed Plus 33 mT/m, EchoSpeed Plus 33 mT/m
5-GAUSS FRINGE FIELD 4.0 m x 2.8 m axial x radial
SHIMMING Active
spacer

• View the DATABASE results for 'Signa Infinity 1.5T™ with Excite' (2).Open this link in a new window

MRI Resources 
Societies - Liver Imaging - Portals - Non-English - RIS - Abdominal Imaging
 
previous      56 - 60 (of 70)     next
Result Pages : [1 2 3 4 5 6 7 8 9 10 11 12 13 14]
 Random Page
 
Share This Page
FacebookTwitterLinkedIn

MR-TIP    
Community   
User
Pass
Forgot your UserID/Password ?  



In 2020 your scanner will probably work with a field strength of :
lower 
1T 
1.5T 
2T 
3T 
7T 
higher 

Look
      Ups





MR-TIP.com uses cookies! By browsing MR-TIP.com, you agree to our use of cookies.

Magnetic Resonance - Technology Information Portal
Member of SoftWays' Medical Imaging Group - MR-TIP • Radiology-TIP • US-TIP • 
Copyright © 2003 - 2018 SoftWays. All rights reserved. [ 21 May 2019]
Terms of Use | Privacy Policy | Advertising
 [last update: 2018-03-08 05:11:00]