Magnetic Resonance - Technology Information Portal Welcome to MRI Technology
Info
  Sheets

Out-
      side
 



 
 'Contrast' 
SEARCH FOR    
 
  2 3 5 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Result : Searchterm 'Contrast' found in 43 terms [] and 326 definitions []
previous     21 - 25 (of 369)     next
Result Pages : [1 2 3 4 5 6 7 8 9]  [10 11 12 13 14 15 16 17 18 19 20 ... ]
Searchterm 'Contrast' was also found in the following services: 
spacer
News  (140)  Resources  (28)  Forum  (72)  
 
Intravascular Contrast AgentsInfoSheet: - Contrast Agents - 
Intro, Overview, 
Characteristics, 
Types of, 
etc.MRI Resource Directory:
 - Contrast Agents -
 
spacer
 
Further Reading:
  Basics:
MR angiography of collateral arteries in a hind limb ischemia model: comparison between blood pool agent Gadomer and small contrast agent Gd-DTPA.
Wednesday, 26 January 2011   by www.ncbi.nlm.nih.gov    
  News & More:
Measurement of rat brain tumor kinetics using an intravascular MR contrast agent and DCE-MRI nested model selection.
Monday, 13 January 2014   by www.ncbi.nlm.nih.gov    
Polysaccharide-Core Contrast Agent as Gadolinium Alternative for Vascular MR
Monday, 8 March 2021   by www.diagnosticimaging.com    
Searchterm 'Contrast' was also found in the following services: 
spacer
Radiology  (106) Open this link in a new windowUltrasound  (149) Open this link in a new window
Negative Oral Contrast AgentsForum -
related threadsInfoSheet: - Contrast Agents - 
Intro, Overview, 
Characteristics, 
Types of, 
etc.MRI Resource Directory:
 - Contrast Agents -
 
Categories of negative oral contrast agents:
Negative oral contrast media are usually based on superparamagnetic particles and act by inducing local field inhomogeneities, which results in shortening of both T1 and T2 relaxation times. Superparamagnetic contrast agents have predominant T2 weighted effects. Biphasic contrast media are agents that have different signal intensities on different sequences, depending on the concentration at which they are used.
Suitable materials for oral contrast agents should have little or no absorption by the stomach or intestines, complete excretion, no motion or susceptibility artifacts, affordability, and uniform marking of the gastrointestinal tract. Benefits of negative oral contrast agents are the reduction of ghosting artifacts caused by the lack of signal. Superparamagnetic iron oxides produce also in low concentrations a noticeable signal loss; but can generate susceptibility artifacts especially in gradient echo sequences. Perfluorochemicals do not dilute in the bowel because they are not miscible with water.
High cost, poor availability, and limited evaluations of side effects are possible disadvantages.
Negative oral contrast agents are used e.g., in MRCP, where the ingestion of 600-900 ml of SPIO cancels out the signal intensity of the lumen (in addition after the injection of a gadolinium-based contrast medium, the enhancement of the inflammatory tissues is clearer seen), and in MR abdominal imaging of Crohn's disease in combination with mannitol.
mri safety guidance
Contrast Guidance
Blueberry or pineapple juices are useable for examinations of the pancreas (MRCP, upper abdominal imaging) as cheep contrast agents, because of the content of magnetic substances (e.g. manganese).

See also Ferristene, Ferumoxsil, Oral Magnetic Particles, Gastrointestinal Imaging.
spacer

• View the DATABASE results for 'Negative Oral Contrast Agents' (7).Open this link in a new window

 
Further Reading:
  Basics:
Components of Oral Contrast Agent for Magnetic Resonance Imaging(.pdf)
   by www.ffcr.or.jp    
MRI Resources 
Used and Refurbished MRI Equipment - IR - Claustrophobia - Musculoskeletal and Joint MRI - MRI Physics - Sequences
 
Positive Oral Contrast AgentsInfoSheet: - Contrast Agents - 
Intro, Overview, 
Characteristics, 
Types of, 
etc.MRI Resource Directory:
 - Contrast Agents -
 
Types of oral contrast agents with positive signal enhancement:
•
•
•
Combinations of these

Ideal oral contrast agents are immiscible with water, biologically inert, have a low viscosity and surface tension. Oral positive contrast agents may improve the separation of bowel loops, the detection of polyps in colon MRI or the assessment of inflammatory bowel in the small intestine. Several positive oral contrast agents are available and they are safe to use, for example gadolinium solution, ferric ammonium citrate, different oil emulsions and pediatric formula.
Unfavorably motion artifacts caused by respiration and peristalsis may be increased in MR imaging. In addition, the signal of the positive contrast medium may decrease caused by dilution in gastrointestinal (GI) secretions. With the use of contrast agents that are immiscible with water, no dilution and accompanying signal loss occur even when the contrast agent is in contact with the intraluminal contents of the GI tract. Another disadvantage may be residual substances in the bowel, resembling masses when enclosed by bright signal. In addition, positive contrast agents may have a similar signal as bright masses, which make their (e.g. lipoma) detection difficult.

See also Gastrointestinal Paramagnetic Contrast Agents, Combination Oral Contrast Agents, Gastrointestinal Diamagnetic Contrast Agents.
 
Images, Movies, Sliders:
 MR Colonography Gadolinium per Rectum  Open this link in a new window
      

Courtesy of  Robert R. Edelman
 
spacer

• View the DATABASE results for 'Positive Oral Contrast Agents' (6).Open this link in a new window

 
Further Reading:
  Basics:
Components of Oral Contrast Agent for Magnetic Resonance Imaging(.pdf)
   by www.ffcr.or.jp    
Hydro-MRI of the Small Bowel: Effect of Contrast Volume, Timing of Contrast Administration, and Data Acquisition on Bowel Distention
Sunday, 1 October 2006   by www.ajronline.org    
Searchterm 'Contrast' was also found in the following services: 
spacer
News  (140)  Resources  (28)  Forum  (72)  
 
Image Contrast Characteristics
 
Variations in the value of TR and TE have an important effect on the control of image contrast characteristics.
Short values of TR (less than e.g. 1000 ms) and TE (less than e.g. 25 ms) are common in images exhibiting T1 contrast.
Long values of TR (greater than e.g. 1500 ms) and TE (greater than e.g.60 ms) are common in images exhibiting T2 contrast.
Middle TR values (e.g. from 1000 to 1500 ms) and middle TE values (e.g. from 25 to 60 ms) are common for density weighted contrast.
The values are depending on the field strength. TR is also a major factor in total scan time.
 
Images, Movies, Sliders:
 Knee MRI Coronal Pd Spir 001  Open this link in a new window
    
 Brain MRI Transversal T1 002  Open this link in a new window
    
 MRI Pancreas T2  Open this link in a new window
    
 Knee MRI Sagittal T1 004  Open this link in a new window
 Knee MRI Transverse 001  Open this link in a new window
 
Radiology-tip.comradContrast,  Low Contrast Detectability
spacer
Medical-Ultrasound-Imaging.comSonographic Features,  Echogenicity
spacer

• View the DATABASE results for 'Image Contrast Characteristics' (6).Open this link in a new window

 
Further Reading:
  Basics:
Musculoskeletal MRI at 3.0 T: Relaxation Times and Image Contrast
Sunday, 1 August 2004   by www.ajronline.org    
IMAGE CONTRAST IN MRI(.pdf)
   by www.assaftal.com    
Searchterm 'Contrast' was also found in the following services: 
spacer
Radiology  (106) Open this link in a new windowUltrasound  (149) Open this link in a new window
Magnitude Contrast AngiographyMRI Resource Directory:
 - MRA -
 
A type of MRA used to display slow flow across a large volume with a good resolution. Two data volumes are measured; the flow-rephased images show bright signal, the flow-dephased image show dark flow, whereby in both data volumes the signal of the stationary tissue looks the same. The data volumes are subtracted and the signal intensity of flowing blood remains.
spacer
MRI Resources 
Resources - Homepages - Claustrophobia - Coils - Abdominal Imaging - IR
 
previous      21 - 25 (of 369)     next
Result Pages : [1 2 3 4 5 6 7 8 9]  [10 11 12 13 14 15 16 17 18 19 20 ... ]
 Random Page
 
Share This Page
FacebookTwitterLinkedIn

MR-TIP    
Community   
User
Pass
Forgot your UserID/Password ?    



MRI is trending to low field magnets :
reduced costs will lead to this change 
AI will close the gap to high field 
only in remote areas 
is only temporary 
never 

Look
      Ups





MR-TIP.com uses cookies! By browsing MR-TIP.com, you agree to our use of cookies.

Magnetic Resonance - Technology Information Portal
Member of SoftWays' Medical Imaging Group - MR-TIP • Radiology-TIP • Medical-Ultrasound-Imaging • 
Copyright © 2003 - 2024 SoftWays. All rights reserved. [ 23 April 2024]
Terms of Use | Privacy Policy | Advertising
 [last update: 2024-02-26 03:41:00]