Radio Frequency Shielding
 
Radio frequency shielding includes the construction of enclosures for the purpose of reducing the transmission of electric or magnetic fields from one space to another (Faraday cage, Faraday shield). Electrically conducted shielding is designed to isolate MRI systems from its environment at the resonant frequencies.
All electronic and computer systems radiate certain frequencies of radio and magnetic waves. They can interfere with other equipment in the vicinity. Magnetic shielding enclosures are used to reduce the levels of RF radiation that enters or leaves the shielded room.
Copper shielding enclosures are designed to filter a range of frequencies under specified conditions. One of the characteristics of copper is its high electrical conductivity. Also its other physical properties like ductility, malleability, and ease of soldering, make it an ideal material for radio frequency shielding. Sheet copper can be formed into any shape and size, and electrically connected to a grounding system to provide an effective RF shielding.

See also MRI Safety
spacer
Searchterm 'Computer' was also found in the following services: 
spacer
Radiology  (40) Open this link in a new windowUltrasound  (21) Open this link in a new window
Radiology Information SystemMRI Resource Directory:
 - RIS -
 
(RIS) Radiology information system means a computer system that stores and processes the information for a radiology department and can be linked to the hospital information system.
The principal purpose of a RIS consists of taking over the general functions of the administration inclusive planning, monitoring and communication of all data regarding patients and its investigations in the radiology. The correct images should reach, at the correct time, the correct users. For this reason the RIS must contain a workflow management in order to simplify and steer the data flow at the individual view stations or devices (laser cameras etc.). The Radiology Information System is optimally complemented with a Picture Archiving and Communication System (PACS).
Collection, storage and administration of patient master data
Archives administration
  • Treatment of requirements
  • Work scheduling
    Account
    Communication (with the hospital information system, MRI scanner, other devices etc.)
    Statistic evaluations
    spacer

    • View the DATABASE results for 'Radiology Information System' (3).Open this link in a new window

     
    Further Reading:
      Basics:
    Healthcare IT Yellow Pages Radiology Information Systems (RIS) Directory
       by www.health-infosys-dir.com    
    MRI Resources 
    Cochlear Implant - Quality Advice - Contrast Enhanced MRI - Manufacturers - MRA - Calculation
     
    Reconstruction Time
     
    Time after completion of examination for the computer to present a digital image.
    spacer

    • View the DATABASE results for 'Reconstruction Time' (5).Open this link in a new window

    Searchterm 'Computer' was also found in the following services: 
    spacer
    News  (38)  Resources  (23)  Forum  (5)  
     
    Siemens Medical Systems
     
    www.siemensmedical.com The range of diagnostics and imaging systems of Siemens Medical Systems covers ultrasound, nuclear medicine, angiography, magnetic resonance, computer tomography and patient monitoring. Siemens is one of the three leading MRI manufacturers, which together account for approximately 80 percent of the MRI machines installed worldwide. Siemens currently offers the Allegra 3T MRI, which is for head scanning only, but the company will also be launching the Trio MRI, a 3T whole body scanner.
    Siemens has formed partnerships with more than ten research institutions and private practitioners to define a comprehensive MRI examination and compare MR to currently established cardiovascular modalities, thereby defining optimal diagnosis and treatment.

    MRI Scanners:

    0.2T to 1.0T:
    1.5T:
    3.0T to 7.0T:
    Hybrid Scanners:
    •

    Mobile Solutions:
    •
    MAGNETOM Espree 1.5T, MAGNETOM Avanto 1.5T and MAGNETOM ESSENZA 1.5T are also offered by Siemens on certified trailers.
    Contact Information
    MAIL
    Siemens Medical Solutions Health Services Corporation
    51 Valley Stream Parkway
    Malvern, PA 19355
    USA
    PHONE
    +1 610 219 6300
    FAX
    +1 610 219 8266
    spacer

    • View the DATABASE results for 'Siemens Medical Systems' (14).Open this link in a new window


    • View the NEWS results for 'Siemens Medical Systems' (3).Open this link in a new window.
     
    Further Reading:
      Basics:
    Siemens Announces FDA Clearance of Magnetom Amira MRI Scanner
    Thursday, 21 January 2016   by www.itnonline.com    
      News & More:
    siemens-healthineers-and-ucsf-research-partnership-proves-significant-energy-cost
    Thursday, 27 April 2023   by www.itnonline.com    
    KinetiCor Wins FDA 510(k) Clearance for Motion Correction System for Siemens MAGNETOM Skyra 3T Scanner
    Wednesday, 19 February 2020   by finance.yahoo.com    
    Ultra-Fast MRI Is Effective in Acute Neurological Emergency Diagnoses
    Wednesday, 15 January 2020   by www.diagnosticimaging.com    
    Siemens Working on Automated Planning of Cardiac MRI Views
    Friday, 8 March 2013   by www.medgadget.com    
    The Most Exciting Equation in MRI Siemens MAGNETOM Verio Combines High-Field Imaging and a 70-cm Open-Bore Design
    Wednesday, 31 October 2007   by www.biospace.com    
    Searchterm 'Computer' was also found in the following services: 
    spacer
    Radiology  (40) Open this link in a new windowUltrasound  (21) Open this link in a new window
    Signa OpenSpeed™InfoSheet: - Devices -
Intro, 
Types of Magnets, 
Overview, 
etc.MRI Resource Directory:
 - Devices -
     
    www.gehealthcare.com/usen/mr/open_speed/index.html From GE Healthcare;
    a friendly and less confining appearance targets the 7% of individuals who refuse to have an MRI because of claustrophobia. This open MRI system is also up to three times faster than other scanners, therefore the Signa OpenSpeed™ reducing exam time and scheduling issues. In addition, a swing table provides better access and supports up to 500 pounds.
    Device Information and Specification
    CLINICAL APPLICATION
    Whole body
    CONFIGURATION
    Integrated transmit and receive body coil; 4 channel head array, 8 channel CTL array, 2 channel shoulder array, 3 channel large extremity array, 3 channel small extremity array, 4 channel foot array, 3 channel wrist array, 4 channel breast array
    SYNCHRONIZATION
    Standard cardiac gating, ECG/peripheral, respiratory gating
    PULSE SEQUENCES
    Standard: SE, IR, 2D/3D GRE and SPGR, Angiography: 2D/3D TOF, 2D/3D Phase Contrast;; 2D/3D FSE, 2D/3D FGRE and FSPGR, SSFP, FLAIR, EPI, optional: 2D/3D Fiesta, FGRET, Spiral, Tensor
    IMAGING MODES
    Localizer, single slice, multislice, volume, fast, POMP, multi slab, cine
    TR
    1.3 to 12000 msec in increments of 1 msec
    TE
    0.4 to 2000 msec in increments of 1 msec
    SINGLE/MULTI SLICE
    Simultaneous scan and reconstruction;; 100 images/second with Reflex 100
    1cm to 40 cm continuous
    2D: 0.8mm - 20mm 3D: 0.1mm - 20mm
    1280 x 1024
    MEASURING MATRIX
    128x512 steps 32 phase//freq.
    PIXEL INTENSITY
    256 gray levels
    0.08 mm; 0.02 mm optional
    175 x 85 x 447 cm
    MAGNET WEIGHT
    8256 kg
    H*W*D
    530 x 175 x 250 cm
    POWER REQUIREMENTS
    200 - 480, 3-phase
    COOLING SYSTEM TYPE
    Liquid helium
    0.03 L/hr, holds 300 L
    STRENGTH
    25 mT/m
    5-GAUSS FRINGE FIELD
    4.7 m/ 3.8 m
    Computerized passive shimming during magnet setup, autoshim per series with automatic table motion to magnet isocenter for each prescription
    spacer

    • View the DATABASE results for 'Signa OpenSpeed™' (2).Open this link in a new window

     
    Further Reading:
      News & More:
    MR Surgical Suite, Improving surgical procedure quality (.pdf)
       by www3.gehealthcare.com    
    MRI Resources 
    MR Guided Interventions - Distributors - Veterinary MRI - Jobs pool - Service and Support - RIS
     
    previous      31 - 35 (of 37)     next
    Result Pages : [1]  [2 3 4 5 6 7 8]
     Random Page
     
    Share This Page
    FacebookTwitterLinkedIn

    MR-TIP    
    Community   
    User
    Pass
    Forgot your UserID/Password ?    



    New acceleration techniques will :
    reduce scan times 
    cause artifacts 
    increase expenses 
    be useful if you have a lot of experience 
    doesn't do much 
    never heard of 

    Look
          Ups





    MR-TIP.com uses cookies! By browsing MR-TIP.com, you agree to our use of cookies.

    Magnetic Resonance - Technology Information Portal
    Member of SoftWays' Medical Imaging Group - MR-TIP • Radiology-TIP • Medical-Ultrasound-Imaging • 
    Copyright © 2003 - 2024 SoftWays. All rights reserved. [ 19 April 2024]
    Terms of Use | Privacy Policy | Advertising
     [last update: 2024-02-26 03:41:00]