Magnetic Resonance - Technology Information Portal Welcome to MRI Technology
Info
  Sheets

Out-
      side
 



 
 'Coherent' 
SEARCH FOR    
 
  2 3 5 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Result : Searchterm 'Coherent' found in 7 terms [] and 9 definitions []
1 - 5 (of 16)     next
Result Pages : [1 2]  [3 4]
Searchterm 'Coherent' was also found in the following services: 
spacer
News  (1)  Forum  (2)  
 
Coherent
 
A state of a spin sample in which all spins in a voxel are in phase.
spacer
 
• Share the entry 'Coherent':  Facebook  Twitter  LinkedIn  
 
• Related Searches:
    • Incoherent Gradient Echo (Gradient Spoiled)
    • Incoherent Spins
    • Gradient Echo Sequence
    • Fast Imaging with Steady Precession
    • Coherent Gradient Echo
 
Further Reading:
  News & More:
New Study Brings MRI on Nanoscale and Quantum Computer One Step Closer to Reality
Monday, 27 February 2012   by www.azonano.com    
Searchterm 'Coherent' was also found in the following service: 
spacer
Ultrasound  (5) Open this link in a new window
Incoherent Spins
 
A state of a set of spins in which the ensemble of spins in a voxel are uniformly distributed with phases between 0 and 2p reducing the transverse magnetization in a voxel to essentially zero.
spacer
MRI Resources 
Calculation - Implant and Prosthesis pool - Jobs - MR Myelography - Pacemaker - PACS
 
Steady State Coherent
 
A state of spins, which leads to an equilibrium magnetization for the longitudinal and transverse magnetization, or, when the magnetization at, or after, each RF pulse is the same as in the previous pulse.
spacer
Searchterm 'Coherent' was also found in the following services: 
spacer
News  (1)  Forum  (2)  
 
Coherent Gradient EchoInfoSheet: - Sequences - 
Intro, 
Overview, 
Types of, 
etc.MRI Resource Directory:
 - Sequences -
 
Coherent gradient echo sequences can measure the free induction decay (FID), generated just after each excitation pulse or the echo formed prior to the next pulse. Coherent gradient echo sequences are very sensitive to magnetic field inhomogeneity. An alternative to spoiling is to incorporate residual transverse magnetization directly into the longitudinal steady state. These GRE sequences use a refocusing gradient in the phase encoding direction during the end module to maximize remaining transverse (xy) magnetization at the time when the next excitation is due, while the other two gradients are, in any case, balanced.
When the next excitation pulse is sent into the system with an opposed phase, it tilts the magnetization in the -a direction. As a result the z-magnetization is again partly tilted into the xy-plane, while the remaining xy-magnetization is tilted partly into the z-direction.
A fully refocused sequence with a properly selected and uniform f would yield higher signal, especially for tissues with long T2 relaxation times (high water content) so it is used in angiographic, myelographic or arthrographic examinations and is used for T2* weighting. The repetition time for this sequence has to be short. With short TR, coherent GE is also useable for breath hold and 3D technique. If the repetition time is about 200 msec there's no difference between spoiled or unspoiled GE. T1 weighting is better with spoiled techniques.
The common types include GRASS, FISP, FAST, and FFE.
The T2* component decreases with long TR and short TE. The T1 time is controlled by flip angle. The common TR is less than 50 ms and the common TE less than 15 ms
Other types have stronger T2 dependence but lower SNR. They include SSFP, CE-FAST, PSIF, and CE-FFE-T2.
Examples of fully refocused FID sequences are TrueFISP, bFFE and bTFE.
spacer

• View the DATABASE results for 'Coherent Gradient Echo' (6).Open this link in a new window

Searchterm 'Coherent' was also found in the following service: 
spacer
Ultrasound  (5) Open this link in a new window
Intravoxel Incoherent Motion
 
(IVIM) Spins moving in fluids with different velocities and possibly in different directions. This is being found to a small degree in all tissues as a result of capillary perfusion or diffusion. Important velocity changes occur as one moves from the vessel wall towards the center of the vessel. Hence, spins (to a variable degree) have different velocities within a single imaging voxel.
This effect can be measured using special pulse sequences such as in diffusion imaging or diffusion weighed imaging. When the velocity differences are marked, as occurs in larger blood vessels, effects due to IVIM are visible in standard MR images and give rise to flow related dephasing. The effects are more visible when longer echo times are used.
spacer

• View the DATABASE results for 'Intravoxel Incoherent Motion' (3).Open this link in a new window

 
Further Reading:
  Basics:
Diffusion Imaging: From Basic Physics to Practical Imaging
1999   by ej.rsna.org    
  News & More:
EVALUATION OF HUMAN STROKE BY MR IMAGING
2000
MRI Resources 
Abdominal Imaging - Image Quality - Case Studies - Sequences - Stent - Safety pool
 
     1 - 5 (of 16)     next
Result Pages : [1 2]  [3 4]
 Random Page
 
Share This Page
FacebookTwitterLinkedIn

MR-TIP    
Community   
User
Pass
Forgot your UserID/Password ?    



How AI will impact MRI :
only diagnostics 
saving time 
reducing cost 
makes planning obsolete 
reduce human knowledge 
not at all 

Look
      Ups





MR-TIP.com uses cookies! By browsing MR-TIP.com, you agree to our use of cookies.

Magnetic Resonance - Technology Information Portal
Member of SoftWays' Medical Imaging Group - MR-TIP • Radiology-TIP • Medical-Ultrasound-Imaging • 
Copyright © 2003 - 2024 SoftWays. All rights reserved. [ 24 April 2024]
Terms of Use | Privacy Policy | Advertising
 [last update: 2024-02-26 03:41:00]