Passive Shielding
 
Magnetic shielding through the use of high permeability material. The iron provides a return path for the stray field lines of magnetic flux and so significantly decreases the flux away from the magnet.
Passive shielding (see also Faraday cage) significantly eases the problems of siting a MR imager in a confined space. Ferromagnetic objects are less prone to being attracted to the magnet, ancillary electronic equipment, credit cards and computer disks can be brought closer to the magnet and the MRI safety limit for pacemaker wearers (the 5 gauss line = 0.5 mT) is reduced from, typically, 10 m to 2 m from the magnet. A passive shield for a whole-body MRI magnet weights many tons. An alternative method of controlling stray field is active shielding.

See also Active Shielding, Magnetic Shielding, Self Shielding and Room Shielding.
spacer

• View the DATABASE results for 'Passive Shielding' (3).Open this link in a new window

 
Further Reading:
  Basics:
Faraday's Law
   by hyperphysics.phy-astr.gsu.edu    
  News & More:
Magnetic Sensitivity of MRI Systems to External Iron: The Design Process
   by www.integratedsoft.com    
Passive Shimming
 
Shimming by adjusting the position of suitable pieces of ferromagnetic metal within or around the main magnet of a MRI system. Typically, the iron is in the form of small plates which are held in removable trays. The magnetic field is plotted, the position and quality of the iron required is then calculated and the appropriate 'shims' put in place. Several repetitions of this process will normally be required in order to achieve the optimum arrangement.
Passive shimming does not replace adjustable shimming, but is installed during the commissioning of a unit to improve the homogeneity of the bare magnet.
spacer

• View the DATABASE results for 'Passive Shimming' (4).Open this link in a new window

MRI Resources 
MRI Physics - Contrast Agents - Most Wanted - Implant and Prosthesis pool - Contrast Enhanced MRI - MR Guided Interventions
 
Peak
 
spacer

• View the NEWS results for 'Peak' (2).Open this link in a new window.

• View the DATABASE results for 'Peak' (22).Open this link in a new window

Peak Arterial Enhancing K-Space SequenceMRI Resource Directory:
 - Sequences -
 
(PEAKS) This function offers consistent arterial enhancement for contrast enhanced MRA studies, augmenting the k-space with filling flexibility.
spacer
PEG-feronInfoSheet: - Contrast Agents - 
Intro, Overview, 
Characteristics, 
Types of, 
etc.
 
Short name: NC100150, PEG-feron, generic name: Feruglose, preliminary trade name: Clariscan™, central moiety: Fe
An ultrasmall superparamagnetic iron oxide under development as a blood pool agent (MRI contrast agent).

See Clariscan™ and NC100150 Injection.
spacer

• View the DATABASE results for 'PEG-feron' (3).Open this link in a new window

MRI Resources 
Claustrophobia - Functional MRI - Fluorescence - Journals - Breast MRI - Guidance
 
previous       31 - 35 (of 121)      next 
P -P7   Pa-Pa   Pa-Pa   Pa-Pa   Pa-Pa   Pa-Pa    Pa-PE    Pe-Pe   Pe-Ph   Ph-Ph   Ph-Ph   Ph-Ph   Ph-Ph   Ph-Ph   Ph-Pi   Pl-Po   Po-Po   Po-Pr   Pr-Pr   Pr-Pr   Pr-Pr   Pr-Pr   Pr-Pu   Pu-Pu   Pu-Pu   
 Random Page
 
Share This Page
FacebookTwitterLinkedIn

MR-TIP    
Community   
User
Pass
Forgot your UserID/Password ?    



New acceleration techniques will :
reduce scan times 
cause artifacts 
increase expenses 
be useful if you have a lot of experience 
doesn't do much 
never heard of 

Look
      Ups





MR-TIP.com uses cookies! By browsing MR-TIP.com, you agree to our use of cookies.

Magnetic Resonance - Technology Information Portal
Member of SoftWays' Medical Imaging Group - MR-TIP • Radiology-TIP • Medical-Ultrasound-Imaging • 
Copyright © 2003 - 2024 SoftWays. All rights reserved. [ 19 April 2024]
Terms of Use | Privacy Policy | Advertising
 [last update: 2024-02-26 03:41:00]