Partial Volume AveragingInfoSheet: - Artifacts -
Case Studies, 
Reduction Index, 
etc.
 
This happens whenever a structure is only partly within the imaging section, pixel or voxel. The consequence is that the signals of the structure and the adjacent or surrounding structures present in the section, pixel or voxel are averaged.
As a result erroneous pixel or voxel signal values result. This can lead to diagnostic misinterpretations.

See also Partial Volume Artifact.
spacer

• View the DATABASE results for 'Partial Volume Averaging' (2).Open this link in a new window

Partial Volume EffectInfoSheet: - Artifacts -
Case Studies, 
Reduction Index, 
etc.
 
The partial volume effect is the loss of contrast between two adjacent tissues in an image caused by insufficient resolution so that more than one tissue type occupies the same voxel (or pixel). That may induce a partial volume artifact, dependent on the size of the image voxel. If fat and water spins occupy the same voxel, their signals interfere destructively. A small amount of water signal may be eliminated by a larger lipid signal from the same voxel, resulting in a voxel that appears to contain only lipid. The partial volume effect is minimal with thin slice thickness and sufficiently high resolution, so that fat and water or other different structures are unlikely to occupy the same voxel.
mri safety guidance
Image Guidance
Take thinner slices, and higher resolution (smaller voxel), but remain this may result in poorer signal to noise ratio in the image.
spacer

• View the DATABASE results for 'Partial Volume Effect' (2).Open this link in a new window

MRI Resources 
General - Cochlear Implant - MRI Centers - Colonography - MRI Training Courses - Diffusion Weighted Imaging
 
Partially Relaxed Fourier TransformationInfoSheet: - Sequences -
Intro, Overview, 
Types of, 
etc.
 
spacer
Pascal
 
(Pa) The SI unit of pressure.
Definition: 1 pascal is equal to 1 N/m2 = 1 J/m3 = 1 kg·m-1·s-2
1 kPa = 0.145 lbf/in2.
Air pressure is measured in hectopascal (hPa), with 1 hPa = 1 millibar.
The unit is named for Blaise Pascal (1623-1662), French philosopher and mathematician.
spacer

• View the DATABASE results for 'Pascal' (3).Open this link in a new window

Passive Device
 
The term 'passive' refers to any medical device that serves its function without the supply of power. Examples of passive devices include but are not limited to aneurysm clips, shunts, scalpels, IV poles, and oxygen bottles.
spacer

• View the DATABASE results for 'Passive Device' (2).Open this link in a new window

 
Further Reading:
  Basics:
Physics of MRI Safety
   by www.aapm.org    
  News & More:
FDA Releases New Guidance On Establishing Safety, Compatibility Of Passive Implants In MR Environments
Tuesday, 16 December 2014   by www.meddeviceonline.com    
MRI Resources 
MRI Accidents - Cochlear Implant - DICOM - MR Guided Interventions - Guidance - Online Books
 
previous       26 - 30 (of 121)      next 
P -P7   Pa-Pa   Pa-Pa   Pa-Pa   Pa-Pa    Pa-Pa    Pa-PE   Pe-Pe   Pe-Ph   Ph-Ph   Ph-Ph   Ph-Ph   Ph-Ph   Ph-Ph   Ph-Pi   Pl-Po   Po-Po   Po-Pr   Pr-Pr   Pr-Pr   Pr-Pr   Pr-Pr   Pr-Pu   Pu-Pu   Pu-Pu   
 Random Page
 
Share This Page
FacebookTwitterLinkedIn

MR-TIP    
Community   
User
Pass
Forgot your UserID/Password ?    



New acceleration techniques will :
reduce scan times 
cause artifacts 
increase expenses 
be useful if you have a lot of experience 
doesn't do much 
never heard of 

Look
      Ups





MR-TIP.com uses cookies! By browsing MR-TIP.com, you agree to our use of cookies.

Magnetic Resonance - Technology Information Portal
Member of SoftWays' Medical Imaging Group - MR-TIP • Radiology-TIP • Medical-Ultrasound-Imaging • 
Copyright © 2003 - 2024 SoftWays. All rights reserved. [ 28 March 2024]
Terms of Use | Privacy Policy | Advertising
 [last update: 2024-02-26 03:41:00]