PresaturationInfoSheet: - Sequences -
Intro, Overview, 
Types of, 
etc.
 
(REST - regional saturation technique / SAT - saturation/ Pre-Sat / spatial Pre-Sat) A specialized technique employing repeated RF excitation of structures adjacent to the ROI for the purpose of reducing or eliminating their phase effect artifacts. This presaturation can be performed on both sides parallel or perpendicular to the slice. Vascular ghosting is eliminated by saturation areas parallel (outside) to the slice plane, because flowing blood produces almost no signal. The possibility of moving presaturation (moving REST / traveling SAT) makes sequence planning and scanning comfortable.
spacer

• View the DATABASE results for 'Presaturation' (17).Open this link in a new window

 
Further Reading:
  Basics:
Techniques of Fat Suppression(.pdf)
   by cds.ismrm.org    
Primovist™InfoSheet: - Contrast Agents - 
Intro, Overview, 
Characteristics, 
Types of, 
etc.MRI Resource Directory:
 - Contrast Agents -
 
Primovist™ (U.S brand name Eovist®) is a highly specific MRI contrast agent for the imaging, detection and characterization of liver conditions, including liver tumors, cysts, as well as other malignant and benign lesions. It is a water-soluble ethoxybenzyl derivative of Gd-DTPA. This compound is taken up by the hepatocytes (approximately 30% of the dose goes to the hepatocytes) and is equally excreted renal and biliary in humans.
Primovist™ brightens the signal of T1 weighted MR images immediately after contrast administration. Dynamic scanning and imaging of the accumulation phase (best after 20 min.) can also be performed after bolus injection of Primovistâ„¢. The hepatocytes uptake will increase the signal intensity of normal liver parenchyma. This results in improved lesion-to-liver contrast because malignant tumors (metastases, the majority of hepatocellular carcinomas) do not contain either hepatocytes or their functioning is hampered.

WARNING: Gadolinium-based contrast agents increase the risk for nephrogenic systemic fibrosis (NSF) in patients with acute or chronic severe renal insufficiency (glomerular filtration rate less than 30 mL/min/1.73m2), or acute renal insufficiency of any severity due to the hepato-renal syndrome or in the perioperative liver transplantation period.
Drug Information and Specification
NAME OF COMPOUND
Gadoxetic acid disodium, Gd-EOB-DTPA
CENTRAL MOIETY
Gd2+
CONTRAST EFFECT
T1, Predominantly positive enhancement
Short T1-relaxation time
PHARMACOKINETIC
50% hepatobiliary, 50% renal excretion
884 mosm/kgH2O
CONCENTRATION
0.25 mol/L
DOSAGE
12,5 - 25 µmol/kg
PREPARATION
Finished product
INDICATION
Liver lesions
DEVELOPMENT STAGE
for sale
DISTRIBUTOR
See below
PRESENTATION
DO NOT RELY ON THE INFORMATION PROVIDED HERE, THEY ARE
NOT A SUBSTITUTE FOR THE ACCOMPANYING PACKAGE INSERT!
Distribution Information
TERRITORY
TRADE NAME
DEVELOPMENT
STAGE
DISTRIBUTOR
EU
Primovist™
for sale
spacer

• View the DATABASE results for 'Primovist™' (7).Open this link in a new window

 
Further Reading:
  Basics:
New MRI liver contrast agent Primovist® approved in EU
Thursday, 30 September 2004   by www.secinfo.com    
New MRI Liver Contrast Medium
Wednesday, 13 October 2004   by www.hospimedica.com    
Important Drug Warning for Gadolinium-Based Contrast Agents
Wednesday, 12 September 2007   by www.ismrm.org    
MAGNETIC RESONANCE IMAGING OF FOCAL LIVER LESIONS(.pdf)
2002
  News & More:
Comparison of liver scintigraphy and the liver-spleen contrast in Gd-EOB-DTPA-enhanced MRI on liver function tests
Thursday, 18 November 2021   by www.nature.com    
EMA's final opinion confirms restrictions on use of linear gadolinium agents in body scans
Friday, 21 July 2017   by www.ema.europa.eu    
FDA Drug Safety Communication: FDA warns that gadolinium-based contrast agents (GBCAs) are retained in the body; requires new class warnings
Tuesday, 19 December 2017   by www.fda.gov    
Gadolinium-containing contrast agents: removal of Omniscan and iv Magnevist, restrictions to the use of other linear agents
Friday, 5 January 2018   by www.gov.uk    
MRI Resources 
Universities - Veterinary MRI - Patient Information - Pediatric and Fetal MRI - Used and Refurbished MRI Equipment - Anatomy
 
PRinciples of Echo Shifting using a Train of ObservationsInfoSheet: - Sequences -
Intro, Overview, 
Types of, 
etc.
 
(PRESTO) PRESTO is a 3 dimensional ultrafast gradient echo sequence that combines the whole brain coverage with T2* weighted imaging. PRESTO is useful for BOLD and perfusion imaging studies. In combination with parallel imaging techniques, PRESTO provides higher temporal resolution and more coverage compared to traditional multi slice imaging. In addition, the sensitivity to susceptibility artifacts and flow phenomena is reduced, compared with EPI techniques, enabling MRI scans throughout the brain including the skull base.

See also T2 Star.
spacer

• View the DATABASE results for 'PRinciples of Echo Shifting using a Train of Observations' (2).Open this link in a new window

 
Further Reading:
  News & More:
Chest MRI Using Multivane-XD, a Novel T2-Weighted Free Breathing MR Sequence
Thursday, 11 July 2019   by www.sciencedirect.co    
T2-Weighted Liver MRI Using the MultiVane Technique at 3T: Comparison with Conventional T2-Weighted MRI
Friday, 16 October 2015   by www.ncbi.nlm.nih.gov    
ProbeForum -
there are related threads
 
The portion of a MR spectrometer comprising the sample container and the RF coils, with some associated electronics. The RF coils may consist of separate receiver and transmitter coils in a crossed coil configuration, or, alternatively, a single coil to perform both functions.
spacer

• View the NEWS results for 'Probe' (4).Open this link in a new window.

• View the DATABASE results for 'Probe' (5).Open this link in a new window

Product Detector
 
Product detector or 'doubly balanced mixer (DBM)' is an electrical device to combine two signals. In MRI, used in the quadrature detector.
spacer

• View the DATABASE results for 'Product Detector' (2).Open this link in a new window

 
Further Reading:
  Basics:
Product Detector
   by en.wikipedia.org    
The Basics of MRI
   by www.cis.rit.edu    
MRI Resources 
Examinations - Implant and Prosthesis - Brain MRI - Hospitals - Journals - Calculation
 
previous       96 - 100 (of 121)      next 
P -P7   Pa-Pa   Pa-Pa   Pa-Pa   Pa-Pa   Pa-Pa   Pa-PE   Pe-Pe   Pe-Ph   Ph-Ph   Ph-Ph   Ph-Ph   Ph-Ph   Ph-Ph   Ph-Pi   Pl-Po   Po-Po   Po-Pr   Pr-Pr    Pr-Pr    Pr-Pr   Pr-Pr   Pr-Pu   Pu-Pu   Pu-Pu   
 Random Page
 
Share This Page
FacebookTwitterLinkedIn

MR-TIP    
Community   
User
Pass
Forgot your UserID/Password ?    



Next big thing in MRI will be :
AI 
remote operator 
personalized protocols 
helium-free 
molecular MRI 
portable MRI 

Look
      Ups





MR-TIP.com uses cookies! By browsing MR-TIP.com, you agree to our use of cookies.

Magnetic Resonance - Technology Information Portal
Member of SoftWays' Medical Imaging Group - MR-TIP • Radiology-TIP • Medical-Ultrasound-Imaging • 
Copyright © 2003 - 2024 SoftWays. All rights reserved. [ 20 April 2024]
Terms of Use | Privacy Policy | Advertising
 [last update: 2024-02-26 03:41:00]