Magnetic Resonance - Technology Information Portal Monday, 6 September 2010••
Info
  Sheets


Out-
      side
 



 
 'MAGNETOM Sonata™' 
SEARCH FOR    
 
  2 3 5 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Result : Searchterm 'MAGNETOM Sonata™' found in 1 term [] and 1 definition []
1 - 2 (of 2)     
Result Pages : [1]
 bottom
MRI Resources  
Anatomy - Manufacturers - Image Quality - Patient Information - Collections - Brain MRI
 
MAGNETOM Sonata™InfoSheet: - Devices -
Intro, 
Types of Magnets, 
Overview, 
etc.MRI Resource Directory:
 - Devices -
 
From Siemens Medical Systems;
www.med.siemens.com/med/d/gg/mr/products/sonata.html while older navigator techniques take up to 40 minutes to create, the high performance of the MAGNETOM Sonata system enables 'complete examinations in less than 15 minutes'. It creates a new standard of diagnostic confidence and moves Cardiac MR from the research setting into routine clinical practice.

Device Information and Specification
CLINICAL APPLICATION Whole body
CONFIGURATION Compact
SURFACE COILS Body, head, spine, knee, neck, TMJ, extremity, head, breast, shoulder, others
SPECTROSCOPY Yes/SVS or CSI opt.
SYNCHRONIZATION ECG/peripheral, respiratory gating
PULSE SEQUENCES GRE, IR, FIR, STIR, TrueIR/FISP, FSE, FLAIR, MT, SS-FSE, MT-SE, MTC, MSE, EPI, 3D DESS//CISS/PSIF, GMR
IMAGING MODES Single, multislice, volume study, multi angle, multi oblique
TR 1.5 msec at 256matrix
TE 0.58 msec at 256matrix
SINGLE/MULTI SLICE 178 images/sec at 256 x 256 at 100% FOV
FOV 0.5 cm - 40 cm
SLICE THICKNESS Min 2D/3D: 0.1/0.05 mm
DISPLAY MATRIX 1024 x 1024 full screen display
MEASURING MATRIX 64 x 64 to 1024 x 1024
PIXEL INTENSITY
SPATIAL RESOLUTION 10 micrometer in plane
MAGNET TYPE Superconducting, single cryogen
BORE DIAMETER
or W x H
60 cm
MAGNET WEIGHT 4050kg, 5500kg in operation
H*W*D 236 x 215 x 160 cm
POWER REQUIREMENTS 380/400/420/440/480 V
COOLING SYSTEM TYPE Single cryogen, 2 stage refrig.
CRYOGEN USE Liquid He
FIELD STRENGTH 1.5 T
STRENGTH 40/70 mT/m
5-GAUSS FRINGE FIELD 2.5 m / 4.0 m
SHIMMING Passive, act.; 1st order std./2nd opt.
spacer
Siemens Medical Systems
 
www.siemensmedical.com The range of diagnostics and imaging systems of Siemens Medical Systems covers ultrasound, nuclear medicine, angiography, magnetic resonance, computer tomography and patient monitoring. Siemens is one of the three leading MRI manufacturers, which together account for approximately 80 percent of the MRI machines installed worldwide. Siemens currently offers the Allegra 3T MRI, which is for head scanning only, but the company will also be launching the Trio MRI, a 3T whole body scanner.
Siemens has formed partnerships with more than ten research institutions and private practitioners to define a comprehensive MRI examination and compare MR to currently established cardiovascular modalities, thereby defining optimal diagnosis and treatment.
MRI Related Product Lines:
MAGNETOM Trio™
MAGNETOM Allegra™
MAGNETOM Avanto™
MAGNETOM C™
MAGNETOM Concerto™
MAGNETOM Espree™
MAGNETOM Harmony™
MAGNETOM Jazz™
MAGNETOM Rhapsody™
MAGNETOM Sonata™
MAGNETOM Symphony™
MAGNETOM Open viva™ the third generation of 0.2 T MAGNETOM Open series demonstrates again how the people-centric approach led to design innovations. Product Specification

Contact Information
MAIL Siemens Medical Solutions Health Services Corporation
51 Valley Stream Parkway
Malvern, PA 19355
USA
PHONE +1 610 219 6300
FAX +1 610 219 8266
E-MAIL contact@med.siemens.de
ONLINE siemensmedical.com
CONTACT INFO PAGE worldwide.med.siemens.com/contact
spacer
Further Reading:
  Basics:
Broadening Perspectives. Increasing Performance.Open this link in a new window
Wednesday, 14 November 2007   by www.medical.siemens.com    
  News & More:
Magnetom Essenza from Siemens – A Trendsetter in Quality and Cost ReductionOpen this link in a new window
Monday, 22 October 2007   by www.medical.siemens.com    
The Most Exciting Equation in MRI Siemens MAGNETOM Verio Combines High-Field Imaging and a 70-cm Open-Bore DesignOpen this link in a new window
Wednesday, 31 October 2007   by www.biospace.com    
 •• There are 3 news about 'Siemens Medical Systems'.
MRI Resources  
Claustrophobia - Pediatric and Fetal MRI - Intraoperative MRI - Calculation - Directories - Stent
 
MRI Resources  
Crystallography - Distributors - IR - Societies - Blood Flow Imaging - Services and Supplies
 
     1 - 2 (of 2)     
Result Pages : [1]
 Random Page
 
MR-TIP    
Community   
User
Pass
Forgot your UserID/Password ?  



The daily magnetic field is risky :
no 
only inside the magnet 
not really 
no, I need it 
yes 
forgot the question 

Look
      Ups





Magnetic Resonance - Technology Information Portal
Member of SoftWays' Medical Imaging Group - MR-TIP • Radiology-TIP • US-TIP • The-Medical-Market
Copyright © 2003 - 2010 SoftWays. All rights reserved.
Terms of Use | Privacy Policy | Advertising
 [last update: 2010-09-06 01:57:00]