Magnetic Resonance - Technology Information Portal Welcome to MRI Technology
Info
  Sheets


Out-
      side
 



 
 'mri cold head' 
SEARCH FOR    
 
  2 3 5 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Result : Searchterm 'mri cold head' found in 0 term [] and 0 definition [], (+ 1 Boolean[] results
1 (of 1)     
Result Pages : [1]
Searchterm 'mri cold head' was also found in the following service: 
spacer
Resources  (3)  
 
MSK-Extreme™InfoSheet: - Devices -
Intro, 
Types of Magnets, 
Overview, 
etc.MRI Resource Directory:
 - Devices -
 
From ONI Medical Systems, Inc.;
www.onicorp.com/ MSK-Extreme™ MRI system is a dedicated high field extremity imaging device, designed to provide orthopedic surgeons and other physicians with detailed diagnostic images of the foot, ankle, knee, hand, wrist and elbow, all with the clinical confidence and advantages derived from high field, whole body MRI units. The light weight (less than 650 kg) of the OrthOne System performs rapid patient studies, is easy to operate, has a patient friendly open environment and can be installed in a practice office or hospital, all at a cost similar to a low field extremity machine.
New features include a more powerful operating system that offers increased scan speed as well as a 160-mm knee coil with higher signal to noise ratio, and the option of a CD burner.

Device Information and Specification
CLINICAL APPLICATION Dedicated extremity imaging
CONFIGURATION Open MRI magnet
SURFACE COILS 16 cm knee, 18 cm lower extremity;; 12.3 cm upper extremity, additional high resolution v-SPEC Coils: 80 mm, 100 mm, or 145 mm.
SPECTROSCOPY No
SYNCHRONIZATION No
PULSE SEQUENCES SE, FSE, GE2D, GE3D, Inversion recovery (IR), Driven Equilibrium, Fat Saturation (FS), STIR, MT, PD, Flow Compensation (FC), RF spoiling, MTE, No Phase Wrap (NPW)
IMAGING MODES Scout, single, multislice, volume
TR 10-10,000ms; 1ms steps
TE 5-150ms; 1 ms steps
SINGLE/MULTI SLICE 2D less than 200 msec/image
FOV 4cm-16cm
SLICE THICKNESS 2D: 2mm-10mm/.1mm incr.
DISPLAY MATRIX Up to 1,000x1,000
MEASURING MATRIX X/Y: 64-512; 2 pixel steps
PIXEL INTENSITY 4,096 grey lvls; 256 lvls in 3D
SPATIAL RESOLUTION 0.05mm
MAGNET TYPE Superconducting
BORE DIAMETER
or W x H
28cm ID x 50cm L
MAGNET WEIGHT 635 kg
H*W*D 146 x 69 x 84 cm
POWER REQUIREMENTS 115VAC, 1phase, 20A; 208VAC, 3 phase, 30A
COOLING SYSTEM TYPE LHe with 2 stage cold head
CRYOGEN USE Negligible
FIELD STRENGTH 1.0 T
STRENGTH 15 mT/m
5-GAUSS FRINGE FIELD 1.25m radial x 1.8m axial
SHIMMING Passive
spacer
 
• Share the entry 'MSK-Extreme™':  Facebook  Twitter  LinkedIn  
 
Further Reading:
  Basics:
MSK Extreme Brochure(.pdf)
   by www.nova-logic.ch    
MSK Extreme Specifications(.pdf)
   by www.nova-logic.ch    
MRI Resources 
Knee MRI - NMR - Patient Information - Sequences - Cochlear Implant - Societies
 
     1 (of 1)     
Result Pages : [1]
 Random Page
 
Share This Page
FacebookTwitterLinkedIn

MR-TIP    
Community   
User
Pass
Forgot your UserID/Password ?  



PET-MRI is :
a valuable new tool 
worth to develop more 
unnecessary 
too expensive 
only for research 
the replacement for PET-CT 
for vets only 

Look
      Ups





Magnetic Resonance - Technology Information Portal
Member of SoftWays' Medical Imaging Group - MR-TIP • Radiology-TIP • US-TIP • The-Medical-Market
Copyright © 2003 - 2014 SoftWays. All rights reserved. [ 16 April 2014]
Terms of Use | Privacy Policy | Advertising
 [last update: 2014-04-14 01:05:21]