Vasovist™ is an albumin-targeted intravascular contrast agent. It is indicated for contrast enhanced MR angiography (CE-MRA) for the visualization of abdominal or limb vessels in patients with suspected or known vascular disease. After IV injection, Vasovist™ binds reversibly to human albumin in plasma, which results in long-lasting increased relaxivity. Imaging from 5 to 50 min is possible. A small unbound portion is, by glomerular filtration, eliminated by the kidneys.
AngioMARK® was the formerly trade name and MS-325 the research name. Currently the phase III clinical trials are completed to determine its efficacy for peripheral vascular disease and coronary artery disease.
In the U.S., EPIX received an approvable letter from the U.S. Food and Drug Administration (FDA) for Vasovist™ in January 2005. In 2009, Epix Pharmaceuticals has sold the U.S., Canadian and Australian rights for its blood pool agent (now named ABLAVAR™), to Lantheus Medical Imaging, Inc..

WARNING: NEPHROGENIC SYSTEMIC FIBROSIS Gadolinium-based contrast agents increase the risk for nephrogenic systemic fibrosis (NSF) in patients with acute or chronic severe renal insufficiency (glomerular filtration rate less than 30 mL/min/1.73m2), or acute renal insufficiency of any severity due to the hepato-renal syndrome or the liver transplantation period.

See also MRI Safety.
Drug Information and Specification
NAME OF COMPOUND
Diphenylcyclohexyl phosphodiester-Gd-DTPA, gadofosveset trisodium, MS-325
CENTRAL MOIETY
Gd2+
CONTRAST EFFECT
T1, predominantly positive enhancement
20-45 mmol-1sec-1, Bo=0,47T
PHARMACOKINETIC
Intravascular, short elimination half life
825 mOsmol/kg H2O
CONCENTRATION
244 mg/mL, 0.25mmol/mL
DOSAGE
0.12 mL/kg, 0.03 mmol/kg
PREPARATION
ready to use
DEVELOPMENT STAGE
approved
DISTRIBUTOR
See below
PRESENTATION
10 mL vials
DO NOT RELY ON THE INFORMATION PROVIDED HERE, THEY ARE
NOT A SUBSTITUTE FOR THE ACCOMPANYING PACKAGE INSERT!
Distribution Information
TERRITORY
TRADE NAME
DEVELOPMENT
STAGE
DISTRIBUTOR
EU
Vasovist
?
?
North America, Australia
for sale
spacer
 
• Share the entry 'Vasovist™':  Facebook  Twitter  LinkedIn  
 
Further Reading:
  Basics:
EPIX Medical's new multimedia Web site features AngioMARK images in 3D
Friday, 5 March 1999
MRI technology combined with contrast agent optimizes diagnosis of cardiovascular disease
1999
MRI Resources 
Breast Implant - NMR - Raman Spectroscopy - Coils - Spectroscopy - MRI Centers
 
ABLAVAR™InfoSheet: - Contrast Agents - 
Intro, Overview, 
Characteristics, 
Types of, 
etc.
 
ABLAVAR™ (formerly named Vasovist) is a blood pool agent for magnetic resonance angiography (MRA), which opens new medical imaging possibilities in the evaluation of aortoiliac occlusive disease (AIOD) in patients with suspected peripheral vascular disease.
ABLAVAR™ binds reversibly to blood albumin, providing imaging with high spatial resolution up to 1 hour after injection, due to its high relaxivity and to the long lasting increased signal intensity of blood.
As with other contrast media: the possibility of serious or life-threatening anaphylactic or anaphylactoid reactions, including cardiovascular, respiratory and/or cutaneous manifestations, should always be considered.

WARNING:
NEPHROGENIC SYSTEMIC FIBROSIS
Gadolinium-based contrast agents increase the risk for nephrogenic systemic fibrosis (NSF) in patients with acute or chronic severe renal insufficiency (glomerular filtration rate less than 30 mL/min/1.73m2), or acute renal insufficiency of any severity due to the hepato-renal syndrome or in the perioperative liver transplantation period.

See also Cardiovascular Imaging, Adverse Reaction, Molecular Imaging, and MRI Safety.
Drug Information and Specification
NAME OF COMPOUND
Diphenylcyclohexyl phosphodiester-Gd-DTPA, gadofosveset trisodium, MS-325
CENTRAL MOIETY
Gd2+
CONTRAST EFFECT
T1, predominantly positive enhancement
20-45 mmol-1sec-1, Bo=0,47T
PHARMACOKINETIC
Intravascular
825 mOsmol/kg H2O
CONCENTRATION
244 mg/mL, 0.25mmol/mL
DOSAGE
0.12 mL/kg, 0.03 mmol/kg
PREPARATION
ready to use
DEVELOPMENT STAGE
FDA approved
DISTRIBUTOR
See below
PRESENTATION
10 mL vials
DO NOT RELY ON THE INFORMATION PROVIDED HERE, THEY ARE
NOT A SUBSTITUTE FOR THE ACCOMPANYING PACKAGE INSERT!
Distribution Information
TERRITORY
TRADE NAME
DEVELOPMENT
STAGE
DISTRIBUTOR
EU
Approved
USA, Canada, Australia
ABLAVAR™
Approved
spacer

• View the DATABASE results for 'ABLAVAR™' (3).Open this link in a new window


• View the NEWS results for 'ABLAVAR™' (1).Open this link in a new window.
 
Further Reading:
  Basics:
Ablavar Prescribing Information
   by www.ablavar.com    
  News & More:
The first FDA-approved blood-pool MR agent offers additional time for imaging and possibly some new applications
Thursday, 1 July 2010   by www.radiologytoday.net    
MRI Resources 
Shoulder MRI - Intraoperative MRI - Stimulator pool - Directories - MRI Accidents - Coils
 
MS-325Forum -
related threadsInfoSheet: - Contrast Agents - 
Intro, Overview, 
Characteristics, 
Types of, 
etc.MRI Resource Directory:
 - Contrast Agents -
 
MS-325 is the formerly code name of gadofosveset trisodium (new trade name Vasovist). MS-325 belongs to a new class of blood pool agents for magnetic resonance angiography (MRA) to diagnose vascular disease. Gadofosveset trisodium has ten times the signal-enhancing power of existing contrast agents as well as prolonged retention in the blood. This enables the rapid acquisition of high resolution MRA's using standard MRI machines.
Gadofosveset trisodium, which is gadolinium-based, stays in the blood stream as a result of transient binding to albumin. Albumin binding offers an additional benefit beyond localization in the blood pool. The contrast agent begins to spin much more slowly, at the rate albumin spins, causing a relaxivity gain that produces a substantially brighter signal than would be possible with freely circulating gadolinium. MS-325 is an intravascular contrast agent intended for use in MRI as an aid in diagnosing aortoiliac occlusive disease in patients with known or suspected peripheral vascular disease (PVD) or abdominal aortic aneurysm (AAA).
Currently clinical trials completed for peripheral vascular disease and coronary artery disease. Additional trials are also being conducted to evaluate MS-325 as an aid in diagnosing breast cancer and suggested that it might be feasible to combine the use of MS-325, injected during peak stress, with delayed high-resolution imaging to identify myocardial perfusion defects.
Vasovist (MS-325) would compete with the contrast agents Ferumoxytol (Code 7228) from AMAG Pharmaceuticals, Inc. and NC100150 Injection from Nycomed Amersham, but their further development is uncertain.
Partners in development: EPIX Pharmaceuticals, Inc., Mallinckrodt Inc., and Bayer Schering Pharma AG. Bayer Schering Pharma has the worldwide marketing rights for the product.
Formerly known under the Mallinckrodt trademark name, AngioMARK®.

See also Classifications, Characteristics, etc.
spacer

• View the DATABASE results for 'MS-325' (4).Open this link in a new window


• View the NEWS results for 'MS-325' (10).Open this link in a new window.
 
Further Reading:
  News & More:
EPIX Medical's new multimedia Web site features AngioMARK images in 3D
Friday, 5 March 1999
MRI technology combined with contrast agent optimizes diagnosis of cardiovascular disease
1999
MRI Resources 
Universities - Chemistry - Developers - Cochlear Implant - Crystallography - Process Analysis
 
Bayer Schering Pharma AGMRI Resource Directory:
 - Manufacturers -
 
www.bayerscheringpharma.de/scripts/pages/en/index.php The Germany-based pharmaceutical company is the result of the take-over of Schering AG by Bayer AG in 2006. The Bayer Schering Pharma AG is part of the Bayer HealthCare AG, which represents the pharmaceutical part of the Bayer Group. Activities of the Bayer Schering Pharma AG are Diagnostic Imaging, Hematology and Cardiology, Oncology, Primary Care, Specialized Therapeutics and Women's Healthcare. The diagnostic imaging part's contrast agents for MRI, x-ray and computed tomography are 'world-market leaders'.

MRI Contrast Agents:
Contact Information
MAIL
Bayer Schering Pharma AG
51368 Leverkusen
GERMANY
PHONE
+49-30-46-81-2431
FAX
+49-30-46-81-8195
spacer

• View the DATABASE results for 'Bayer Schering Pharma AG' (22).Open this link in a new window


• View the NEWS results for 'Bayer Schering Pharma AG' (25).Open this link in a new window.
 
Further Reading:
  News & More:
Drastic market changes with MRI contrast media and PET radiopharmaceuticals emerging as most promising segments
Thursday, 21 October 2004   by www.news-medical.net    
Epix Pharmaceuticals to shut down
Tuesday, 21 July 2009   by boston.bizjournals.com    
MRI Resources 
Corporations - Health - Contrast Enhanced MRI - Pregnancy - Non-English - Stent
 
Blood Pool AgentsInfoSheet: - Contrast Agents - 
Intro, Overview, 
Characteristics, 
Types of, 
etc.MRI Resource Directory:
 - Contrast Agents -
 
Blood pool agents (intravascular contrast agents) remain in the blood for a prolonged time compared with conventional contrast agents, which diffuse quickly into the interstitial space. Magnetic resonance angiography (MRA), cardiovascular imaging, or contrast enhanced MRIs are possible over an hour or more. This advantage over conventional MRI contrast media allows also higher resolution MRA of several territories using respiratory or cardiac gating techniques with a single contrast bolus.
Different types of blood pool contrast agents:
Blood pool MRI contrast agents with their longer intravascular circulation can be designed to be targeted to necrotic myocardium, to assess myocardial viability, or tumor directed to provide better diagnostic information for various tumors. A disadvantage of the use of blood pool agents for MRA is that the separation of arteries and veins is more difficult because they are present in both and the overlapping of those vessels is disturbing. This can be solved by e.g. different MIP segmentation algorithms.

See also Necrosis Avid Contrast Agent, Tumor Specific Agents, Feruglose, Gadofosveset Trisodium (Vasovist), Ultrasmall Superparamagnetic Iron Oxide and Contrast Medium.
spacer

• View the DATABASE results for 'Blood Pool Agents' (16).Open this link in a new window


• View the NEWS results for 'Blood Pool Agents' (1).Open this link in a new window.
 
Further Reading:
  Basics:
Ablavar Prescribing Information
   by www.ablavar.com    
Lantheus Medical Imaging, Inc. Launches ABLAVAR™ (Gadofosveset Trisodium), a New Diagnostic Magnetic Resonance Angiography Agent
Wednesday, 20 January 2010   by www.radiopharm.com    
Blood-Pool Imaging Using Technetium-99m-Labeled Liposomes(.pdf)
   by jnm.snmjournals.org    
  News & More:
Multimodal Nanoparticles for Quantitative Imaging(.pdf)
Tuesday, 13 December 2011   by alexandria.tue.nl    
MAGNETIC RESONANCE IMAGING OF FOCAL LIVER LESIONS(.pdf)
2002
MRI Resources 
Spectroscopy pool - NMR - Pregnancy - RIS - Fluorescence - Artifacts
 
     1 - 5 (of 9)     next
Result Pages : [1]  [2]
 Random Page
 
Share This Page
FacebookTwitterLinkedIn

MR-TIP    
Community   
User
Pass
Forgot your UserID/Password ?    



New acceleration techniques will :
reduce scan times 
cause artifacts 
increase expenses 
be useful if you have a lot of experience 
doesn't do much 
never heard of 

Look
      Ups





MR-TIP.com uses cookies! By browsing MR-TIP.com, you agree to our use of cookies.

Magnetic Resonance - Technology Information Portal
Member of SoftWays' Medical Imaging Group - MR-TIP • Radiology-TIP • Medical-Ultrasound-Imaging • 
Copyright © 2003 - 2024 SoftWays. All rights reserved. [ 16 April 2024]
Terms of Use | Privacy Policy | Advertising
 [last update: 2024-02-26 03:41:00]