Panorama 0.23T™InfoSheet: - Devices -
Intro, 
Types of Magnets, 
Overview, 
etc.MRI Resource Directory:
 - Devices -
 
From Philips Medical Systems;
www.medical.philips.com/main/products/mri/products/panoramafamily/panorama0.23t_rt/features/ the Panorama 0.23 T, providing a new design optimized for patient comfort, faster reconstruction time than before (300 images/second) and new gradient specifications. Philips' Panorama 0.23 T I/T supports MR-guided interventions, resulting in minimally invasive procedures, more targeted surgery, reduced recovery time and shorter hospital stays. Optional OptoGuide functionality enables real-time needle tracking. Philips' Panorama 0.23 T™ R/T is the first and only open MRI system to enable radiation therapy planning using MR data sets. The Panorama also features the new and consistent Philips User Interface, an essential element of the Vequion clinical IT family of products and services.

Device Information and Specification
CLINICAL APPLICATION Whole body
CONFIGURATION Open MRI/C-arm
SURFACE COILS Head, head-neck, extremity M-L, neck, body/spine S-XL, shoulder, bilateral breast, wrist, TMJ, flex XS-S-M-L-XL-XXL
SPECTROSCOPY No
SYNCHRONIZATION ECG/peripheral: Optional/optional, respiratory gating
PULSE SEQUENCES SE, FE, IR, FFE, DEFFE, DESE, TSE, DETSE, Single shot SE, DRIVE, Balanced FFE, MRCP, Fluid Attenuated Inversion Recovery, Turbo FLAIR, IR-TSE, T1-STIR TSE, T2-STIR TSE, Diffusion Imaging, 3D SE, 3D FFE, MTC;; Angiography: CE-ANGIO, MRA 2D, 3D TOF
IMAGING MODES Single, multislice, volume study, dynamic, SIMEX, multi chunk 3D, multiple stacks
TR Min. 6.2 msec
TE Min. 2.8 msec
SINGLE/MULTI SLICE 50 slices/sec
FOV 0.4 cm - 40 cm
SLICE THICKNESS 0.4 mm
DISPLAY MATRIX 1280 X 1024
MEASURING MATRIX Up to 512 x 512
PIXEL INTENSITY 256 gray scale
SPATIAL RESOLUTION 0.78 mm
MAGNET TYPE Resistive/iron core
BORE DIAMETER
or W x H
Open x 46 cm x infinite (side-first patient entry)
MAGNET WEIGHT 13110 kg
H*W*D 196 x 121 x 176 cm
POWER REQUIREMENTS 400/480 V
COOLING SYSTEM TYPE Closed loop chilled water (chiller included)
CRYOGEN USE N/A
FIELD STRENGTH 0.23 T
STRENGTH 19 mT/m
5-GAUSS FRINGE FIELD 2.4 m / 3.7 m
SHIMMING Passive/active
spacer
 
Further Reading:
  News & More:
Magnetic resonance imaging guided musculoskeletal interventions at 0.23T: Chapter 4. Materials and methods
2002
Searchterm 'Open MRI' was also found in the following services: 
spacer
Radiology  (2) Open this link in a new windowUltrasound  (1) Open this link in a new window
Panorama 0.6T™InfoSheet: - Devices -
Intro, 
Types of Magnets, 
Overview, 
etc.MRI Resource Directory:
 - Devices -
 
From Philips Medical Systems;
www.medical.philips.com/main/products/mri/products/panoramafamily/panorama0.23t_rt/features/ Panorama 0.6 T is the Philips Mid-Field Open MRI system. It is the most open MR scanner in the market, optimized for patient comfort and faster reconstruction time.

Device Information and Specification
CLINICAL APPLICATION Whole body
CONFIGURATION Open MRI/C-arm
SURFACE COILS Head, head-neck, extremity, neck, body/spine M-XL, shoulder, bilateral breast, wrist, TMJ, flex XS-S-M-L-XL-XXL
SPECTROSCOPY No
SYNCHRONIZATION ECG/peripheral: Optional/yes, respiratory gating
PULSE SEQUENCES SE, FE, IR, STIR, FFE, DEFFE, DESE, TSE, DETSE, Single shot SE, DRIVE, Balanced FFE, MRCP, Fluid Attenuated Inversion Recovery, Turbo FLAIR, IR-TSE, T1-STIR TSE, T2-STIR TSE, Diffusion Imaging, 3D SE, 3D FFE, Contrast Perfusion Analysis, MTC;; Angiography: CE-ANGIO, MRA 2D, 3D TOF
IMAGING MODES Single, multislice, volume study, dynamic, SIMEX, multi chunk 3D, multiple stacks
TR Min. 4.6 msec
TE Min. 2.3 msec
SINGLE/MULTI SLICE 50 slices/sec
FOV 0.4 cm - 42 cm
SLICE THICKNESS 0.4 mm
DISPLAY MATRIX 1280 X 1024
MEASURING MATRIX Up to 512 x 512
PIXEL INTENSITY 256 gray scale
SPATIAL RESOLUTION 0.78 mm
MAGNET TYPE Superconducting / iron core
BORE DIAMETER
or W x H
Open x 47 cm x infinite (side-first patient entry)
MAGNET WEIGHT 38000 kg
H*W*D 254 x 244 x 325 cm
POWER REQUIREMENTS 400/480 V
COOLING SYSTEM TYPE Liquid helium//air cool
CRYOGEN USE 0.00 L/hr helium
FIELD STRENGTH 0.6 T
STRENGTH 20 mT/m
5-GAUSS FRINGE FIELD 2.4 m / 2.5 m
SHIMMING Passive/active
spacer

• View the DATABASE results for 'Panorama 0.6T™' (2).Open this link in a new window

MRI Resources 
Supplies - Homepages - MR Guided Interventions - Stent - Musculoskeletal and Joint MRI - RIS
 
Panorama 1.0T™InfoSheet: - Devices -
Intro, 
Types of Magnets, 
Overview, 
etc.MRI Resource Directory:
 - Devices -
 
From Philips Medical Systems;
www.medical.philips.com/main/products/mri/products/panoramafamily/panorama1.0t_rt/features/ this active shielded member of the Panorama product line combines the advantages of one 1.0 T system's with the possibilities of an open MRI system. The open design helps ease anxiety for claustrophobic patients and increased patient comfort whereby the field strength provides spectacular image quality and fast patient throughput.
Device Information and Specification
CLINICAL APPLICATION Whole body
CONFIGURATION Vertical Field open MRI post design
SURFACE COILS Vertically opposed solenoids, head, head-neck, extremity, neck, body/spine M-XL, shoulder, bilateral breast, wrist, TMJ, flex XS-S-M-L-XL-XXL
SPECTROSCOPY No
SYNCHRONIZATION ECG/peripheral: Optional/yes, respiratory gating
PULSE SEQUENCES SE, FE, IR, STIR, FFE, DEFFE, DESE, TSE, DETSE, Single shot SE, DRIVE, Balanced FFE, MRCP, FLAIR, Turbo FLAIR, IR-TSE, T1-STIR TSE, T2-STIR TSE, Diffusion Imaging, 3D SE, 3D FFE, Contrast Perfusion Analysis, MTC;; Angiography: CE-ANGIO, MRA 2D, 3D TOF
IMAGING MODES Single, multislice, volume study, dynamic, SIMEX, multi chunk 3D, multiple stacks
TR Min. 4.6 msec
TE Min. 2.3 msec
SINGLE/MULTI SLICE 50 slices/sec
FOV 0.4 cm - 42 cm
SLICE THICKNESS 0.4 mm
DISPLAY MATRIX 1280 X 1024
MEASURING MATRIX Up to 512 x 512
PIXEL INTENSITY 256 gray scale
SPATIAL RESOLUTION 0.78 mm
MAGNET TYPE Superconducting
BORE DIAMETER
or W x H
Open x 47 cm x infinite (side-first patient entry)
MAGNET WEIGHT
H*W*D
POWER REQUIREMENTS 400/480 V
COOLING SYSTEM TYPE Liquid helium
CRYOGEN USE
FIELD STRENGTH 1.0 T
STRENGTH 20 mT/m
5-GAUSS FRINGE FIELD
SHIMMING Passive/active
spacer

• View the DATABASE results for 'Panorama 1.0T™' (2).Open this link in a new window

Searchterm 'Open MRI' was also found in the following services: 
spacer
News  (36)  Resources  (21)  Forum  (12)  
 
Signa OpenSpeed™InfoSheet: - Devices -
Intro, 
Types of Magnets, 
Overview, 
etc.MRI Resource Directory:
 - Devices -
 
From GE Healthcare;
www.gehealthcare.com/usen/mr/open_speed/index.html a friendly and less confining appearance targets the 7% of individuals who refuse to have an MRI because of claustrophobia. This open MRI system is also up to three times faster than other scanners, therefore the Signa OpenSpeed™ reducing exam time and scheduling issues. In addition, a swing table provides better access and supports up to 500 pounds.

Device Information and Specification
CLINICAL APPLICATION Whole body
CONFIGURATION Open MRI
SURFACE COILS Integrated transmit and receive body coil;; 4 channel head array, 8 channel CTL array, 2 channel shoulder array, 3 channel large extremity array, 3 channel small extremity array, 4 channel foot array, 3 channel wrist array, 4 channel breast array
SPECTROSCOPY No
SYNCHRONIZATION Standard cardiac gating, ECG/peripheral, respiratory gating
PULSE SEQUENCES Standard: SE, IR, 2D/3D GRE and SPGR, Angiography: 2D/3D TOF, 2D/3D Phase Contrast;; 2D/3D FSE, 2D/3D FGRE and FSPGR, SSFP, FLAIR, EPI, optional: 2D/3D Fiesta, FGRET, Spiral, Tensor
IMAGING MODES Localizer, single slice, multislice, volume, fast, POMP, multi slab, cine
TR 1.3 to 12000 msec in increments of 1 msec
TE 0.4 to 2000 msec in increments of 1 msec
SINGLE/MULTI SLICE Simultaneous scan and reconstruction;; 100 images/second with Reflex 100
FOV 1cm to 40 cm continuous
SLICE THICKNESS 2D: 0.8mm - 20mm 3D: 0.1mm - 20mm
DISPLAY MATRIX 1280 x 1024
MEASURING MATRIX 128x512 steps 32 phase//freq.
PIXEL INTENSITY 256 gray levels
SPATIAL RESOLUTION 0.08 mm; 0.02 mm optional
MAGNET TYPE Superconducting
BORE DIAMETER
or W x H
175 x 85 x 447 cm
MAGNET WEIGHT 8256 kg
H*W*D 530 x 175 x 250 cm
POWER REQUIREMENTS 200 - 480, 3-phase
COOLING SYSTEM TYPE Liquid helium
CRYOGEN USE 0.03 L/hr, holds 300 L
FIELD STRENGTH 0.7 T
STRENGTH 25 mT/m
5-GAUSS FRINGE FIELD 4.7 m/ 3.8 m
SHIMMING Computerized passive shimming during magnet setup, autoshim per series with automatic table motion to magnet isocenter for each prescription
spacer

• View the DATABASE results for 'Signa OpenSpeed™' (2).Open this link in a new window

 
Further Reading:
  News & More:
MR Surgical Suite, Improving surgical procedure quality (.pdf)
   by www3.gehealthcare.com    
Searchterm 'Open MRI' was also found in the following services: 
spacer
Radiology  (2) Open this link in a new windowUltrasound  (1) Open this link in a new window
Signa Ovation™InfoSheet: - Devices -
Intro, 
Types of Magnets, 
Overview, 
etc.MRI Resource Directory:
 - Devices -
 
From GE Healthcare;
www.gehealthcare.com/usen/mr/ovation/index.html the Signa Ovation™ is a patient-friendly open MRI scanner designed not only to handle a typical patient mix, but to accommodate larger patients, patients who are claustrophobic, and others who have difficulty tolerating the close quarters of conventional MR machines.
Device Information and Specification
CLINICAL APPLICATION Whole body
CONFIGURATION Open MRI
SURFACE COILS Integrated transmit and receive body coil;; head coil, 4 channel neurovascular array, 8 channel CTL array, 2 channel shoulder array, 3 channel large extremity array, 3 channel small extremity array, 4 channel foot array, 3 channel wrist array
SPECTROSCOPY No
SYNCHRONIZATION Standard cardiac gating, ECG/peripheral, respiratory gating
PULSE SEQUENCES Standard: SE, IR, 2D/3D GRE and SPGR, 2D/3D TOF, 2D/3D FSE, 2D/3D FGRE and FSPGR, SSFP, FLAIR, EPI, optional: 2D/3D Fiesta, true chem sat, fat/water separation, single shot diffusion EPI, line scan diffusion
IMAGING MODES Localizer, single slice, multislice, volume, fast, POMP, multi slab, cine, slice and frequency zip, extended dynamic range, tailored RF
TR 1.3 to 12000 msec in increments of 1 msec
TE 0.4 to 2000 msec in increments of 1 msec
SINGLE/MULTI SLICE Simultaneous scan and reconstruction;; 80 images/second reconstruction
FOV 3cm to 40 cm continuous
SLICE THICKNESS 2D: 1.4mm - 20mm 3D: 0.2mm - 20mm
DISPLAY MATRIX 1280 x 1024
MEASURING MATRIX 128x512 steps 32 phase//freq.
PIXEL INTENSITY 256 gray levels
SPATIAL RESOLUTION 0.08 mm; 0.02 mm optional
MAGNET TYPE Permanent
BORE DIAMETER
or W x H
175 x 85 x 447 cm
MAGNET WEIGHT 19200 kg
H*W*D 530 x 175 x 250 cm
POWER REQUIREMENTS 200 - 480, 3-phase
GRADIENT COOLING None
FIELD STRENGTH 0.35 T
MAX. GRADIENT AMPLITUDE 19 mT/m
5-GAUSS FRINGE FIELD 2.5 m/2.5 m
SHIMMING Computerized passive shimming during magnet setup, autoshim per series with automatic table motion to magnet isocenter for each prescription
spacer

• View the DATABASE results for 'Signa Ovation™' (2).Open this link in a new window

MRI Resources 
Anatomy - Spectroscopy - Implant and Prosthesis pool - Breast MRI - Pathology - Homepages
 
previous      11 - 15 (of 37)     next
Result Pages : [1]  [2 3 4 5 6 7 8]
 Random Page
 
Share This Page
FacebookTwitterLinkedIn

MR-TIP    
Community   
User
Pass
Forgot your UserID/Password ?  



Your MRI scanner(s) in 5 years should be :
more automated 
much quicker 
quiet 
voice controlled 
iPhone compatible 
as it is right now 

Look
      Ups





MR-TIP.com uses cookies! By browsing MR-TIP.com, you agree to our use of cookies.

Magnetic Resonance - Technology Information Portal
Member of SoftWays' Medical Imaging Group - MR-TIP • Radiology-TIP • US-TIP • The-Medical-Market
Copyright © 2003 - 2016 SoftWays. All rights reserved. [ 17 December 2017]
Terms of Use | Privacy Policy | Advertising
 [last update: 2017-12-12 07:30:00]