MAGNETOM Concerto™InfoSheet: - Devices -
Intro, 
Types of Magnets, 
Overview, 
etc.MRI Resource Directory:
 - Devices -
 
From Siemens Medical Systems;
www.med.siemens.com/med/d/gg/mr/products/concerto.htm the MAGNETOM Concerto is easy to site and has low life cycle costs due to the permanent magnet. The powerful gradient system with 20 mT/m and a slew rate of 40 T/m/s permits high field applications on a low field open MRI system. The three-sided fully open magnet results in maximum acceptance of claustrophobic or anxious patients and patient access.
Device Information and Specification
CLINICAL APPLICATION Whole body
CONFIGURATION Open MRI
SURFACE COILS Body coil, head brain, spine, knee, neck, TMJ, extremity, shoulder, others
SPECTROSCOPY No
PULSE SEQUENCES GRE, IR, FIR, STIR, TrueIR/FISP, FSE, MT, SS-FSE, MT-SE, MTC, MSE, GMR, fat/water sat./exc.
IMAGING MODES Single, multislice, volume study, multi angle
SLICE THICKNESS Min 2D/3D: 0.1/0.05 mm
DISPLAY MATRIX 512 x 512 full screen display
MEASURING MATRIX 64 x 64 to 512 x 512
SPATIAL RESOLUTION 22 micrometer
MAGNET TYPE Permanent
MAGNET WEIGHT 11 000 kg
POWER REQUIREMENTS 380/400/420/440/480 V
FIELD STRENGTH 0.2 T
STRENGTH 20 mT/m
SHIMMING Passive, active
spacer
 
• Related Searches:
    • MRI Equipment
    • Device
    • Hardware
    • Open MRI
    • Coil
Searchterm 'Open MRI' was also found in the following services: 
spacer
Radiology  (2) Open this link in a new windowUltrasound  (1) Open this link in a new window
MAGNETOM Jazz™InfoSheet: - Devices -
Intro, 
Types of Magnets, 
Overview, 
etc.MRI Resource Directory:
 - Devices -
 
From Siemens Medical Systems;
www.med.siemens.com/med/d/gg/mr/products/jazz.htm This open MRI system is a dedicated extremity scanner, which is easy to use and easy to install. Whether you want to use it as a supplement to your whole-body scanner or you want to specialize in orthopedic exams, MAGNETOM Jazz™ offers you a cost effective opportunity to make the most of your capabilities.
Device Information and Specification
CLINICAL APPLICATION Extremity
CONFIGURATION Open MRI
SURFACE COILS Extremity, knee, shoulder, others
SPECTROSCOPY No
PULSE SEQUENCES GRE, IR, FIR, STIR, TrueIR/FISP, FSE, MT, SS-FSE, MT-SE, MTC, MSE, GMR, fat/water sat./exc.
IMAGING MODES Single, multislice, volume study, multi angle
SLICE THICKNESS Min 2D/3D: 0.1/0.05 mm
DISPLAY MATRIX 512 x 512 full screen display
MEASURING MATRIX 64 x 64 to 512 x 512
SPATIAL RESOLUTION 22 micrometer
MAGNET TYPE Permanent
MAGNET WEIGHT 1800 kg
POWER REQUIREMENTS 380/400/420/440/480 V
FIELD STRENGTH 0.2 T
STRENGTH 20 mT/m
SHIMMING Passive, active
spacer

• View the DATABASE results for 'MAGNETOM Jazz™' (2).Open this link in a new window

MRI Resources 
Online Books - Mobile MRI Rental - Education pool - Health - Cardiovascular Imaging - Pregnancy
 
MAGNETOM Rhapsody™InfoSheet: - Devices -
Intro, 
Types of Magnets, 
Overview, 
etc.MRI Resource Directory:
 - Devices -
 
From Siemens Medical Systems;
www.med.siemens.com/med/d/gg/mr/products/rhapsody.htm the MAGNETOM Rhapsody™. This open MRI system offers the proven image quality of 1.0 Tesla. In addition to the resulting broad range of applications, the open magnet of the high field system MAGNETOM Rhapsody™ facilitates examination of claustrophobic and pediatric patients. And the system allows for expanded interventional applications.
Device Information and Specification
CLINICAL APPLICATION Whole body
CONFIGURATION Open MRI
SURFACE COILS Body, head, spine, knee, neck, TMJ, extremity, shoulder, others
SPECTROSCOPY No
PULSE SEQUENCES GRE, IR, FIR, STIR, TrueIR/FISP, FSE, FLAIR, MT, SS-FSE, MT-SE, MTC, MSE, EPI, GMR, fat/water sat./exc.
IMAGING MODES Single, multislice, volume study, multi angle, multi oblique
SLICE THICKNESS Min 2D/3D: 0.1/0.05 mm
DISPLAY MATRIX 1024 x 1024 full screen display
MEASURING MATRIX 64 x 64 to 1024 x 1024
MAGNET TYPE Superconductive
POWER REQUIREMENTS 380/400/420/440/480 V
FIELD STRENGTH 1.0 T
STRENGTH 20 mT/m
SHIMMING Passive, active
spacer

• View the DATABASE results for 'MAGNETOM Rhapsody™' (2).Open this link in a new window

Searchterm 'Open MRI' was also found in the following services: 
spacer
News  (36)  Resources  (21)  Forum  (12)  
 
OPART™InfoSheet: - Devices -
Intro, 
Types of Magnets, 
Overview, 
etc.MRI Resource Directory:
 - Devices -
 
From Toshiba America Medical Systems Inc.;
www3.toshiba.co.jp/medical/products/mr/opart/index.htm OPART™ is a 0.35 T superconducting open MR system featuring cryogenless operation. Superconducting speed and performance are combined with the patient access advantages of open MRI design for unmatched clinical versatility. OPART™ features innovative technologies such as digital RF, high speed gradients and optimized RF coils, which support advanced MRI applications.

Device Information and Specification
CLINICAL APPLICATION Whole body
CONFIGURATION Open MRI
SURFACE COILS Quadrature, solenoid and multi-channel configurations
SPECTROSCOPY No
SYNCHRONIZATION ECG/peripheral optional, respiratory gating
PULSE SEQUENCES SE, FE, IR, FastSE, FastIR, FastFLAIR, Fast STIR, FastFE, FASE, Hybrid EPI, Multi Shot EPI; Angiography: 2D(gate/non-gate)/3D TOF, SORS-STC
IMAGING MODES Single, multislice, volume study
MAGNET TYPE Superconducting
BORE DIAMETER
or W x H
55 cm, vertical opening
POWER REQUIREMENTS 380/400/415/440/480 V
COOLING SYSTEM TYPE Cryogenless
FIELD STRENGTH 0.35 T
STRENGTH 25 mT/m
SHIMMING Passive, active
spacer

• View the DATABASE results for 'OPART™' (2).Open this link in a new window

Searchterm 'Open MRI' was also found in the following services: 
spacer
Radiology  (2) Open this link in a new windowUltrasound  (1) Open this link in a new window
Opera (E-SCAN™ XQ)InfoSheet: - Devices -
Intro, 
Types of Magnets, 
Overview, 
etc.MRI Resource Directory:
 - Devices -
 
www.esaote.com/products/MRI/eScanXQ/products1.htm

Manufactured by Esaote S.p.A.; a low field open MRI scanner with permanent magnet for orthopedic use. The outstanding feature of this MRI system is a patient friendly design with 24 cm diameter, which allows the imaging of extremities and small body parts like shoulder MRI. The power consumption is around 1.3 kW and the needed minimum floor space is an area of 16 sq m.
At RSNA 2006 Hologic Inc. introduced a new dedicated extremity MRI scanner, the Opera. Manufactured by Esaote is the Opera a redesign of Esaote's 0.2 Tesla E-Scan XQ platform, which now enables complete imaging of all extremities, including hip and shoulder applications. 'Real-time positioning' reportedly speeds patient setup and reduces exam times.
Esaote North America and Hologic Inc are the U.S. distributors of this MRI device.


Device Information and Specification
CLINICAL APPLICATION Dedicated extremity
CONFIGURATION Open MRI
SURFACE COILS Extremity, shoulder (2), flex coil, knee dual phased array, ankle//foot dual phased array, hand//wrist dual phased array coil
PULSE SEQUENCES SE, GE, IR, STIR, FSE, 3D CE, GE-STIR, 3D GE, ME, TME, HSE
IMAGING MODES Single, multislice, volume study, fast scan, multi slab
TR 10 - 5000 msec
TE 6 - 110 msec
SINGLE SLICE 0.6 sec/image
MULTISLICE 0.6 sec/image
FOV 17 cm
SLICE THICKNESS 2D: 2 mm - 10 mm;
3D: 0.6 mm - 10 mm
DISPLAY MATRIX 512 x 512
MEASURING MATRIX 256 x 256 maximum
PIXEL INTENSITY 4096 gray lvls, 256 lvls in 3D
SPATIAL RESOLUTION 0.4 mm
MAGNET TYPE Permanent
BORE DIAMETER
or W x H
24 cm H, open
MAGNET WEIGHT 2250 kg, 4960 lbs
H*W*D 79 x 65 x 85 cm
POWER REQUIREMENTS 2,0 kW; 110/220 V single phase
FIELD STRENGTH 0.2 T
STRENGTH 20 mT/m
5-GAUSS FRINGE FIELD, radial/axial 150 cm/130 cm
SHIMMING Passive

spacer

• View the DATABASE results for 'Opera (E-SCAN™ XQ)' (2).Open this link in a new window

 
Further Reading:
  News & More:
E-Scan, 510(k) Summary(.pdf)
Saturday, 15 May 2004   by www.accessdata.fda.gov    
MRI Resources 
Intraoperative MRI - Manufacturers - Cochlear Implant - NMR - Pregnancy - PACS
 
previous      6 - 10 (of 37)     next
Result Pages : [1]  [2 3 4 5 6 7 8]
 Random Page
 
Share This Page
FacebookTwitterLinkedIn

MR-TIP    
Community   
User
Pass
Forgot your UserID/Password ?  



The impact of TTIP/TPP on the MRI scanner market will bring :
more variety 
better scanners 
more risk 
less regulation 
cheaper scanners 
Lost in Translation 
no change at all 

Look
      Ups





MR-TIP.com uses cookies! By browsing MR-TIP.com, you agree to our use of cookies.

Magnetic Resonance - Technology Information Portal
Member of SoftWays' Medical Imaging Group - MR-TIP • Radiology-TIP • US-TIP • The-Medical-Market
Copyright © 2003 - 2016 SoftWays. All rights reserved. [ 23 August 2017]
Terms of Use | Privacy Policy | Advertising
 [last update: 2017-08-21 15:12:00]