Scalar
 
A quantity or measurement, having only magnitude.
spacer
Searchterm 'Magnitude' was also found in the following services: 
spacer
Radiology  (6) Open this link in a new windowUltrasound  (2) Open this link in a new window
Sensitive Plane
 
Technique of selecting a plane for sequential plane imaging by using an oscillating magnetic field gradient and filtering out the corresponding time dependent part of the NMR signal. The gradient used, is at right angles to the desired plane and the magnitude of the oscillating magnetic field gradient is equal to zero only in the desired plane.
spacer
MRI Resources 
Shielding - MRI Technician and Technologist Career - MRI Centers - MR Myelography - Movies - Mass Spectrometry
 
Tailored Pulse
 
Shaped pulse whose magnitude (and possibly phase) is varied with time in a predetermined manner. Affects the frequency components of a RF pulse in a manner determined by the Fourier transformation of the pulse.
spacer
 
Further Reading:
  News & More:
Factors influencing flip angle mapping in MRI: RF pulse shape, slice-select gradients, off-resonance excitation, and B0 inhomogeneities.
Tuesday, 1 August 2006   by www.ncbi.nlm.nih.gov    
Searchterm 'Magnitude' was also found in the following services: 
spacer
News  (4)  Forum  (3)  
 
Transformer
 
Electrical device operating on the principle of mutual induction to change the magnitude of current and voltage.
spacer

• View the DATABASE results for 'Transformer' (2).Open this link in a new window

Searchterm 'Magnitude' was also found in the following services: 
spacer
Radiology  (6) Open this link in a new windowUltrasound  (2) Open this link in a new window
Turbo Inversion RecoveryInfoSheet: - Sequences - 
Intro, 
Overview, 
Types of, 
etc.MRI Resource Directory:
 - Sequences -
 
( TIR / TIRM / IR-TSE - Inversion Recovery Turbo Spin Echo / FIR - Fast Inversion Recovery)
A turbo / fast spin echo sequence with long TI for fluid suppression (FLAIR) or with short TI for fat suppression (STIR). This sequence allows for a true inversion recovery display that shows the arithmetic sign of the signal.
TIRM means a turboIR with a magnitude display.

See also Inversion Recovery, Inversion Recovery Sequence and Fast Spin Echo.
spacer
 
Further Reading:
  News & More:
Accurate T1 Quantification Using a Breath-hold Inversion Recovery TrueFISP Sequence
2003   by rsna2003.rsna.org    
MRI Resources 
Service and Support - Musculoskeletal and Joint MRI - MRI Centers - Image Quality - Open Directory Project - Libraries
 
previous      21 - 25 (of 26)     next
Result Pages : [1]  [2 3 4 5 6]
 Random Page
 
Share This Page
FacebookTwitterLinkedIn

MR-TIP    
Community   
User
Pass
Forgot your UserID/Password ?    



New acceleration techniques will :
reduce scan times 
cause artifacts 
increase expenses 
be useful if you have a lot of experience 
doesn't do much 
never heard of 

Look
      Ups





MR-TIP.com uses cookies! By browsing MR-TIP.com, you agree to our use of cookies.

Magnetic Resonance - Technology Information Portal
Member of SoftWays' Medical Imaging Group - MR-TIP • Radiology-TIP • Medical-Ultrasound-Imaging • 
Copyright © 2003 - 2024 SoftWays. All rights reserved. [ 19 April 2024]
Terms of Use | Privacy Policy | Advertising
 [last update: 2024-02-26 03:41:00]