Magnetic Resonance - Technology Information Portal Welcome to MRI Technology
Info
  Sheets

Out-
      side
 



 
 'Magnetic Induction' 
SEARCH FOR    
 
  2 3 5 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Result : Searchterm 'Magnetic Induction' found in 1 term [] and 4 definitions [], (+ 3 Boolean[] results
1 - 5 (of 8)     next
Result Pages : [1]  [2]
MRI Resources 
Cardiovascular Imaging - Examinations - Used and Refurbished MRI Equipment - Safety Training - Fluorescence - Contrast Enhanced MRI
 
Magnetic Induction
 
(B) Also called magnetic flux density with the SI unit tesla (T) usually denoted by the symbol B. The magnetic induction is the net magnetic effect from an externally applied magnetic field and the resulting magnetization.
The symbol H was used for the magnetic field (measured in amperes per meter (A/m)). However, this distinction is often ignored, and both quantities are often referred to as the magnetic field.
B is proportional to H (B = μH).
(μ is the magnetic permeability (in henries per meter) of the medium)
spacer
 
• Share the entry 'Magnetic Induction':  Facebook  Twitter  LinkedIn  
 
Further Reading:
  Basics:
Magnet basics
   by my.execpc.com    
  News & More:
Linear Collider Final FocusMagnet Construction
   by www.bnl.gov    
MRI Resources 
Pacemaker - MRI Physics - MRI Centers - Most Wanted - Coils - Patient Information
 
B0
 
[B0] A conventional symbol for the main magnetic field strength (magnetic flux density or induction) in a MRI system. Although historically used, H0 (units of magnetic field strength, ampere//meter) should be distinguished from the more appropriate B0 [units of magnetic induction, tesla].
In current MR systems it has a constant value over time varying from 0.02 to 4 T. Field strengths of 0.5 T and above are generated with superconductive magnets. High field strengths have a better signal to noise ratio (SNR). The optimal imaging field strength for clinical imaging is between 0.5 and 2.0 T.

See also the related poll result: 'In 2010 your scanner will probably work with a field strength of'
spacer

• View the DATABASE results for 'B0' (41).Open this link in a new window

 
Further Reading:
  Basics:
Factors influencing flip angle mapping in MRI: RF pulse shape, slice-select gradients, off-resonance excitation, and B0 inhomogeneities.
Tuesday, 1 August 2006   by www.ncbi.nlm.nih.gov    
Magnetic Field
   by hyperphysics.phy-astr.gsu.edu    
  News & More:
Turbo-FLASH Based Arterial Spin Labeled Perfusion MRI at 7 T
Thursday, 20 June 2013   by www.plosone.org    
Penn researchers to get 7 Tesla whole-body MRI system
Monday, 28 August 2006   by www.eurekalert.org    
Optimizing SPIR and SPAIR fat suppression
Tuesday, 30 November 2004   by clinical.netforum.healthcare.philips.com    
MRI Resources 
Implant and Prosthesis - MRI Accidents - Musculoskeletal and Joint MRI - Databases - Homepages - General
 
Coil LoadingInfoSheet: - Coils - 
Intro, 
Overview, 
etc.
 
The interaction of the patient with the RF coil, which causes shifts of the resonance frequency and damping of the coil's resonance and hence reduction of the quality factor because of magnetic induction and dielectric losses in the patient.
The design and construction of a MRI coil is determined by the load on the coil. The load is either a phantom or the actual sample being imaged.

See also Radio Frequency Coil.
spacer

• View the DATABASE results for 'Coil Loading' (2).Open this link in a new window

MRI Resources 
Collections - Equipment - Implant and Prosthesis pool - Shoulder MRI - Quality Advice - Societies
 
InductionForum -
related threads
 
spacer

• View the DATABASE results for 'Induction' (31).Open this link in a new window


• View the NEWS results for 'Induction' (1).Open this link in a new window.
 
Further Reading:
  Basics:
Free induction decay
   by en.wikipedia.org    
MRI Resources 
Stent - Blood Flow Imaging - Libraries - Open Directory Project - Nerve Stimulator - RIS
 
Magnetic FieldForum -
related threads
 
(H) The region surrounding a magnet (or current carrying conductor) is equipped with certain properties like that a small magnet in such a region experiences a torque that tends to align it in a given direction. Magnetic field is a vector quantity; the direction of the field is defined as the direction that the north pole of the small magnet points when in equilibrium.
mri safety guidance
MRI Safety Guidance
A magnetic field produces a magnetizing force on a body within it. Although the dangers of large magnetic fields are largely hypothetical, this is an area of potential concern for safety limits. Formally, the forces experienced by moving charged particles, current carrying wires, and small magnets in the vicinity of magnet are due to magnetic induction (B), which includes the effect of magnetization, while the magnetic field (H) is defined so as not to include magnetization. However, both B and H are often loosely used to denote magnetic fields.
spacer

• View the DATABASE results for 'Magnetic Field' (219).Open this link in a new window


• View the NEWS results for 'Magnetic Field' (25).Open this link in a new window.
 
Further Reading:
  Basics:
Magnet basics
   by my.execpc.com    
Magnetic Field
   by hyperphysics.phy-astr.gsu.edu    
Magnetic Field
   by en.wikipedia.org    
How strong are magnets?
   by my.execpc.com    
  News & More:
Impact of Magnetic Field Inhomogeneity on the Quality of Magnetic Resonance Images and Compensation Techniques: A Review
Saturday, 1 October 2022   by www.dovepress.com    
Impact of the Lorentz force on electron track structure and early DNA damage yields in magnetic resonance-guided radiotherapy
Friday, 30 September 2022   by www.nature.com    
Two stuck to MRI machine for 4 hrs
Tuesday, 11 November 2014   by www.mumbaimirror.com    
Commission proposes to revamp rules to protect EU workers from harmful electromagnetic fields
Tuesday, 14 June 2011   by finchannel.com    
Magnetic fields drive drug-loaded nanoparticles to reduce blood vessel blockages in an animal study
Monday, 19 April 2010   by www.eurekalert.org    
MRI Resources 
Process Analysis - Safety pool - Pediatric and Fetal MRI - Crystallography - MRI Accidents - Devices
 
     1 - 5 (of 8)     next
Result Pages : [1]  [2]
 Random Page
 
Share This Page
FacebookTwitterLinkedIn

MR-TIP    
Community   
User
Pass
Forgot your UserID/Password ?    



Next big thing in MRI will be :
AI 
remote operator 
personalized protocols 
helium-free 
molecular MRI 
portable MRI 

Look
      Ups





MR-TIP.com uses cookies! By browsing MR-TIP.com, you agree to our use of cookies.

Magnetic Resonance - Technology Information Portal
Member of SoftWays' Medical Imaging Group - MR-TIP • Radiology-TIP • Medical-Ultrasound-Imaging • 
Copyright © 2003 - 2024 SoftWays. All rights reserved. [ 25 April 2024]
Terms of Use | Privacy Policy | Advertising
 [last update: 2024-02-26 03:41:00]