Magnetic Resonance - Technology Information Portal Welcome to MRI Technology
Info
  Sheets

Out-
      side
 



 
 'Magnet' 
SEARCH FOR    
 
  2 3 5 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Result : Searchterm 'Magnet' found in 97 terms [] and 515 definitions []
previous     56 - 60 (of 612)     next
Result Pages : [1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20]  [ ... ]
Searchterm 'Magnet' was also found in the following services: 
spacer
News  (897)  Resources  (213)  Forum  (82)  
 
Transverse Magnetization
 
The xy component of the net magnetization vector at right angles to the main magnetic field. The precession of the transverse magnetization at the Larmor frequency is responsible for the detectable MRI signal. In the absence of externally applied RF energy, the transverse magnetization will decay to zero with a characteristic time constant of T2, or more strictly T2*.
spacer
 
• Related Searches:
    • Nuclear Magnetic Resonance Signal
    • Incoherent Spins
    • Gradient Echo Sequence
    • Excitation
    • Bipolar Gradient Pulse
 
Further Reading:
  Basics:
Measuring T1 and T2 Relaxation - Introductory NMR & MRI from Magritek
   by www.azom.com    
Searchterm 'Magnet' was also found in the following services: 
spacer
Radiology  (44) Open this link in a new windowUltrasound  (33) Open this link in a new window
Longitudinal Magnetization
 
(Mz) The component of the net magnetization vector in the direction of the static magnetic field (z). After RF excitation, this vector returns to its equilibrium value at a rate characterized by the time constant T1.
spacer

• View the DATABASE results for 'Longitudinal Magnetization' (25).Open this link in a new window

MRI Resources 
Education - Implant and Prosthesis - Corporations - Contrast Agents - Case Studies - Manufacturers
 
Magnetohydrodynamic Effect
 
This effect is an additional electrical charge generated by ions in blood (loaded particles) moving perpendicular to the magnetic field. At 1.5 T, no significant changes are expected; at 6.0 T a 10% blood pressure change is expected. A blood pressure increase is predicted theoretically for a field of 10 T. This is claimed to be caused by interaction of induced electrical potentials and currents within a solution, e.g. blood, and an electrical volume force causing a retardation in the direction opposite to the fluid flow. This decrease in blood flow-velocity must be compensated for by an elevation in pressure.
Static magnetic field gradients of 0.01 T/cm (100 G/cm) make no significant difference in the membrane transport processes. The influence of a static magnetic field upon erythrocytes is not sufficient to provoke sedimentation, as long as there is a normal blood circulation.
mri safety guidance
MRI Safety Guidance
The magnetohydrodynamic effect which results from a voltage occurring across a vessel in a magnetic field, is irrelevant at the field strengths used.
spacer

• View the DATABASE results for 'Magnetohydrodynamic Effect' (3).Open this link in a new window

 
Further Reading:
  News & More:
Measuring magnetic force field distributions in microfluidic devices: Experimental and numerical approaches
Saturday, 2 December 2023   by analyticalsciencejournals.onlinelibrary.wiley.com    
Searchterm 'Magnet' was also found in the following services: 
spacer
News  (897)  Resources  (213)  Forum  (82)  
 
Nuclear Magnetic ResonanceMRI Resource Directory:
 - NMR -
 
(NMR) Nuclear Magnetic Resonance is a physical phenomenon of the magnetic property of nuclei, which have a positive nuclear spin quantum number.
Under the influence of an external static magnetic field this nuclei will precess about the direction of the magnetic field with an angular frequency (Larmor frequency). Through absorption and emission of RF energy (gradients, RF coils) at the resonance frequency (Larmor equation) and the processing of this raw data by the Fourier transformation - physical, chemical, electronic, and structural information about molecules can be obtained (NMR Magnetic Resonance Spectroscopy, Magnetic Resonance Imaging).
spacer

• View the DATABASE results for 'Nuclear Magnetic Resonance' (11).Open this link in a new window


• View the NEWS results for 'Nuclear Magnetic Resonance' (1).Open this link in a new window.
 
Further Reading:
  Basics:
MRI's inside story
Thursday, 4 December 2003   by www.economist.com    
Nuclear magnetic resonance with no magnets
Wednesday, 18 May 2011   by www.physorg.com    
  News & More:
Neuromelanin-Sensitive MRI Identified as a Potential Biomarker for Psychosis
Sunday, 10 February 2019   by www.nimh.nih.gov    
A powder to enhance NMR signals
Thursday, 12 December 2013   by phys.org    
New Paradigm for Nanoscale Resolution MRI Experimentally Achieved
Friday, 27 September 2013   by www.sciencedaily.com    
Searchterm 'Magnet' was also found in the following services: 
spacer
Radiology  (44) Open this link in a new windowUltrasound  (33) Open this link in a new window
iMotion™ 1.5 Tesla MagnetInfoSheet: - Devices -
Intro, 
Types of Magnets, 
Overview, 
etc.MRI Resource Directory:
 - Devices -
 
www.imris.com/ The mobile intraoperative iMotion system produces real-time images used for MR guided surgery and offers functional magnetic resonance imaging, MR spectroscopy, perfusion imaging, and diffusion weighted imaging capabilities.
The iMotion 1.5 T magnet moves to the patient, gliding in and out of place as needed, without affecting surgical, anesthetic, and nursing management.

See also Intraoperative Magnetic Resonance Imaging, MR Guided Interventions.
Device Information and Specification
CLINICAL APPLICATION
Whole body
CONFIGURATION
Mobile compact
Whole body, intra-operative head, neck volume, atlas head//neck vascular quadrature phased array, spine quadrature, C/T/L spine phased array, small joint, large joint, TMJ bilateral, shoulder phased array, extremity quadrature volume, wrist, hand quadrature, general purpose flexible, pelvis/abdomen phased array, body quadrature, phased array flexible, breast bilateral
SYNCHRONIZATION
Standard cardiac gating, ECG/peripheral, respiratory gating
PULSE SEQUENCES
SE, IR, TSE, EPI, Diffusion, Perfusion, Angiography
IMAGING MODES
Localizer, single slice, multislice, volume
Active
spacer

• View the DATABASE results for 'iMotion™ 1.5 Tesla Magnet' (2).Open this link in a new window

MRI Resources 
Most Wanted - Nerve Stimulator - Movies - Spectroscopy - Education pool - Safety pool
 
previous      56 - 60 (of 612)     next
Result Pages : [1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20]  [ ... ]
 Random Page
 
Share This Page
FacebookTwitterLinkedIn

MR-TIP    
Community   
User
Pass
Forgot your UserID/Password ?    



Next big thing in MRI will be :
AI 
remote operator 
personalized protocols 
helium-free 
molecular MRI 
portable MRI 

Look
      Ups





MR-TIP.com uses cookies! By browsing MR-TIP.com, you agree to our use of cookies.

Magnetic Resonance - Technology Information Portal
Member of SoftWays' Medical Imaging Group - MR-TIP • Radiology-TIP • Medical-Ultrasound-Imaging • 
Copyright © 2003 - 2024 SoftWays. All rights reserved. [ 28 March 2024]
Terms of Use | Privacy Policy | Advertising
 [last update: 2024-02-26 03:41:00]