Isotope
 
Atomic nuclei that contain the same number of protons, but differ in the number of neutrons in the nucleus of the atom for the element concerned. For example, 1H, 2H, and 3H are the three isotopes of hydrogen, otherwise known as proton, deuterium, and tritium. Various isotopes have different nuclear magnetic moments and different resonant frequencies. Many isotopes have no magnetic moment and are therefore not observable by MR.

See also Isomer.
spacer
 
• Share the entry 'Isotope':  Facebook  Twitter  LinkedIn  
 
Further Reading:
  News & More:
The top 5 ways medical physics has changed health care
Thursday, 28 February 2008   by www.eurekalert.org    
Searchterm 'Isotope' was also found in the following services: 
spacer
Radiology  (21) Open this link in a new windowUltrasound  (2) Open this link in a new window
Ventilation AgentsInfoSheet: - Contrast Agents - 
Intro, Overview, 
Characteristics, 
Types of, 
etc.MRI Resource Directory:
 - Contrast Agents -
 
Inert hyperpolarized gases are under development for imaging air spaces, including those in the lungs. Because they mostly contain air and water, lungs are difficult organs to image.
These ventilation agents (gases) have potential in lung imaging and are currently used in studies of the pulmonary ventilation:
perfluorinated gases
aerosolized gadolinium-DTPA
hyperpolarized gases (xenon-129, helium-3)
molecular oxygen

Specific isotopes of inert gases can be hyperpolarized. Hyperpolarized is a state in which almost all of the atoms nuclei are spinning in the same direction. Once the nuclei in the isotope 3He have been hyperpolarized using a laser, they remain in this state for several days. The inert, hyperpolarized gas can then be used in a lung imaging study, where the high concentration of polarized nuclei provides a sharp contrast in MRI. The technique is already being developed with a view to commercialization by Magnetic Imaging Technologies in Durham, North Carolina. According to the company, existing MRI equipment can be used with a few minor modifications, along with a gas polarizer. The technique could provide early detection and monitoring of pulmonary disease.
Hyperpolarized 129Xe can also be used as a magnetic resonance tracer because of its MR-enhanced sensitivity combined with its high solubility. This isotope differs from 3He in that it can dissolve in the blood. Strong enhancement of the nuclear spin polarization of xenon in the gas phase can be achieved by optical pumping of rubidium and subsequent spin-exchange with the xenon nuclei. This technique can increase the magnetic resonance signal of xenon by five orders of magnitude, thus allowing NMR detection of xenon in very low concentration. MR spectroscopy and imaging of optically polarized xenon shows considerable potential for medical applications (see also back projection imaging).
Nycomed Amersham anticipated the market for inert gases in pulmonary imaging. The company obtained an exclusive license for the use of helium (He) and xenon (Xe) as MRI contrast agents. Currently, the US FDA has not yet approved the commercial distribution of inert gas imaging equipment, because the technique is still undergoing trials.
spacer

• View the DATABASE results for 'Ventilation Agents' (3).Open this link in a new window

 
Further Reading:
  Basics:
New oxygen-enhanced MRI scan 'helps identify most dangerous tumours'
Thursday, 10 December 2015   by www.dailymail.co.uk    
Low-Field MRI of Laser Polarized Noble Gas
   by xenon.unh.edu    
  News & More:
Hyperpolarized Gas MRI for Pulmonary Disease Assessment: Interview with Richard Hullihen, CEO of Polarean Imaging
Wednesday, 9 September 2020   by www.medgadget.com    
Pumpkin-shaped molecule enables 100-fold improved MRI contrast: new agent for detecting pathological cells
Tuesday, 13 October 2015   by phys.org    
MRI Mapping of Cerebrovascular Reactivity via Gas Inhalation Challenges
Wednesday, 17 December 2014   by www.jove.com    
Using MRI to study gas reactions
Thursday, 31 January 2008   by www.theengineer.co.uk    
New Technique Reveals Insights Into Lung Disease
Thursday, 13 December 2007   by www.sciencedaily.com    
MRI Resources 
Devices - Stimulator pool - Spectroscopy - Equipment - Cochlear Implant - Contrast Agents
 
Element
 
An element consists of atoms having the same structure and the same chemically reaction.
See also Magnetic Resonance Spectroscopy, Isomer, Isotope, Helium, and Gadolinium.
Mathematically, an element or member of a set is any one of the separate objects that make up that set. Elements in arrays (parallel arrangement of many identical items) are used in MRI coils.

See also Array Coil, Array Processor, and Array Spatial Sensitivity Encoding Technique.
spacer

• View the DATABASE results for 'Element' (40).Open this link in a new window

Searchterm 'Isotope' was also found in the following services: 
spacer
News  (1)  Resources  (5)  
 
Helium
 
The element helium (He) was discovered 1868 when P.J.C. Janssen and N. Lockyer detected a new line in the solar spectrum during the solar eclipse. Lockyer and E. Frankland suggested the name helium (Gr. Helios, the sun) for the new element. In 1895, helium was discovered in the uranium mineral cleveite and in 1907 it was found out that alpha particles are helium nuclei.
Properties: Helium belongs to the noble gases, is colorless, odorless, and occurs in two naturally isotopes, helium 3 and helium 4. As an inert gas, helium does not react chemically largely and don't burns. Helium 4 makes up over 99% of naturally occurring helium atoms. Helium is extracted from natural gas e.g. present in various radioactive minerals as a decay product. Deposits and sources are in the USA, Poland, the USSR, and a few in India. The rare deposits and increased consumption lead to a shortage of this gas.
K. Onnes worked for many years to liquefy helium, which persisted as a gas to the lowest temperature. Helium does not freeze at atmospheric pressure. The density of helium vapor at his boiling point of 4.2 Kelvin is very high, with the vapor expanding greatly when heated to room temperature. Nb, Tc, Pb, La, V, and Ta are superconductors at liquid helium temperature. Liquid helium is commonly used as a cryogen for superconducting magnets. A rapid evaporation of the cryogen is named Quench. See also Quenching.
mri safety guidance
MRI Safety Guidance
Cryogenic liquids and their associated cold vapors can produce effects on the skin similar to a thermal burn and can cause frostbite. Prolonged breathing of extremely cold gases may damage the lungs and in absence of enough air or oxygen, asphyxiation and death can occur. Unprotected skin can stick to very cold metal (e.g. cooled by liquid helium) and then tear when pulled away.
spacer

• View the DATABASE results for 'Helium' (43).Open this link in a new window


• View the NEWS results for 'Helium' (2).Open this link in a new window.
 
Further Reading:
  Basics:
Superfluid helium-4
Monday, 12 February 2018   by en.wikipedia.org    
Cryogenic Liquids and their Hazards
   by www.ccohs.ca    
Liquid Helium
   by hyperphysics.phy-astr.gsu.edu    
  News & More:
Renergen surges after xceptional™ helium concentration reports
Monday, 29 March 2021   by www.businesslive.co.za    
Not just balloons: Helium shortage may deflate MRIs, airbags and research
Friday, 3 May 2019   by eu.usatoday.com    
Liquid helium, the lifeblood of MRI machines
Tuesday, 5 March 2019   by www.gasworld.com    
Preclinical Imaging Systems Reduce Environmental Impact
Monday, 4 November 2019   by www.itnonline.com    
Huge newfound deposit of helium will keep MRI scanners running
Monday, 27 June 2016   by www.newscientist.com    
Philips launches Ingenia Ambition X 1.5T MR with industry-first fully sealed magnet for more productive, helium-free operations
Tuesday, 11 September 2018   by www.philips.com    
Tech firms, medical research threatened by helium shortage
Thursday, 19 September 2013   by www.livemint.com    
How 9/11 Made The Global Helium Shortage Worse
Thursday, 3 July 2014   by www.popsci.com    
Cooling MRI magnets without a continuous supply of scarce helium
Tuesday, 13 August 2013   by www.wired.co.uk    
Searchterm 'Isotope' was also found in the following services: 
spacer
Radiology  (21) Open this link in a new windowUltrasound  (2) Open this link in a new window
Isomer
 
Isomers are molecules with the same chemical formula and often with the same kinds of bonds between atoms, but in which the atoms are arranged differently.

See also Isotope.
spacer

• View the DATABASE results for 'Isomer' (3).Open this link in a new window

MRI Resources 
Pacemaker - Devices - Databases - Non-English - Universities - Jobs pool
 
     1 - 5 (of 6)     next
Result Pages : [1]  [2]
 Random Page
 
Share This Page
FacebookTwitterLinkedIn

MR-TIP    
Community   
User
Pass
Forgot your UserID/Password ?    



Next big thing in MRI will be :
AI 
remote operator 
personalized protocols 
helium-free 
molecular MRI 
portable MRI 

Look
      Ups





MR-TIP.com uses cookies! By browsing MR-TIP.com, you agree to our use of cookies.

Magnetic Resonance - Technology Information Portal
Member of SoftWays' Medical Imaging Group - MR-TIP • Radiology-TIP • Medical-Ultrasound-Imaging • 
Copyright © 2003 - 2024 SoftWays. All rights reserved. [ 23 April 2024]
Terms of Use | Privacy Policy | Advertising
 [last update: 2024-02-26 03:41:00]