Magnetic Resonance - Technology Information Portal Welcome to MRI Technology
Info
  Sheets

Out-
      side
 



 
 'Image' 
SEARCH FOR    
 
  2 3 5 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Result : Searchterm 'Image' found in 19 terms [] and 434 definitions []
previous     56 - 60 (of 453)     next
Result Pages : [1 2 3 4]  [5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 ... ]
Searchterm 'Image' was also found in the following services: 
spacer
News  (255)  Resources  (73)  Forum  (128)  
 
Synchronization, Respiratory
 
The respiratory phase can be used to control imaging either by only acquiring the image data during a particular portion of the respiratory cycle (which increases image acquisition time) or by adjusting the sequence of image data collection according to the phase of the respiratory cycle in such a way as to minimize motion-induced artifacts in the reconstructed image.

See also Respiratory Ordered Phase Encoding.
spacer
MRI Resources 
MRCP - Most Wanted - MRI Physics - Spectroscopy - Safety pool - Spine MRI
 
T2 WeightedForum -
related threads
 
Often used to indicate an image where most of the contrast between tissues or tissue states is due to differences in tissue T2 created typically by using longer TE and TR times.
This term may be misleading in that the potentially important effects of tissue density differences and the range of tissue T2 values are often ignored.
Choosing the machine parameters such that TR greater than T1 (typically greater than 2 000 ms) and TE less than T2 (typically greater than 100 ms) and noting that (1-exp(-TR/T1) = 1 for TR/T1 much greater than 1, will reduce Eq. 1 to the expression
Mxy = Mxy0exp(-TE/T2)
which is dependent on T2 only, hence the term T2 weighting. Therefore T2 weighted image contrast state is approached by imaging with a TR long compared to tissue T1 (to reduce T1 contribution to image contrast) and a TE between the longest and shortest tissue T2s of interest. A TR greater than 3 times the longest T1 is required for the T1 effect to be less than 5%. Due to the wide range of T1 and T2 and tissue density values that can be found in the body, an image that is T2 weighted for some tissues may not be so for others.
See also T2 Time.
Lesions with short T2 are (dark in T2 weighted sequences):
acute haemorrhage (deoxyHb)
haemosiderin
physiologic iron (basal ganglia, etc.)
mucinous lesions.
 
Images, Movies, Sliders:
 MRI Pancreas T2  Open this link in a new window
    
 Anatomic MRI of the Neck  Open this link in a new window
    
SlidersSliders Overview

 MRI Liver T2  Open this link in a new window
    
 
spacer

• View the DATABASE results for 'T2 Weighted' (46).Open this link in a new window


• View the NEWS results for 'T2 Weighted' (1).Open this link in a new window.
 
Further Reading:
  Basics:
A paired dataset of T1- and T2-weighted MRI at 3 Tesla and 7 Tesla
Thursday, 27 July 2023   by www.nature.com    
Clinical evaluation of a speed optimized T2 weighted fast spin echo sequence at 3.0 T using variable flip angle refocusing, half-Fourier acquisition and parallel imaging
Wednesday, 25 October 2006
Fast T2 weighted imaging by PSIF at 0.2T for interventional MRI.(.pdf)
   by cds.ismrm.org    
  News & More:
Single Sequence Magnetic Resonance Imaging in Serous Otitis Media
Friday, 28 April 2023   by www.cureus.com    
Non-metallic T2-MRI agents based on conjugated polymers
Monday, 11 April 2022   by www.nature.com    
MRI T2 Mapping of the Knee Providing Synthetic Morphologic Images: Comparison to Conventional Turbo Spin-Echo MRI
Tuesday, 1 October 2019   by pubs.rsna.org    
New MRI technique offers faster diagnosis of multiple sclerosis
Monday, 1 February 2016   by medicalxpress.com    
MRI Resources 
Pathology - Spine MRI - MRI Reimbursement - Spectroscopy pool - Manufacturers - MRI Technician and Technologist Schools
 
Volume Imaging
 
Imaging techniques in which NMR signals are gathered from the whole object volume to be imaged at once, with appropriate encoding pulse RF and gradient sequences to encode positions of the spins. Many sequential plane imaging techniques can be generalized to volume imaging, at least in principle. Advantages include potential improvement in signal to noise ratio by including signal from the whole volume at once; disadvantages include a bigger computational task for image reconstruction and longer image acquisition times (although the entire volume can be imaged from the one set of data). Also called simultaneous volume imaging.
 
Images, Movies, Sliders:
 Knee MRI Transverse 001  Open this link in a new window
 
spacer

• View the DATABASE results for 'Volume Imaging' (7).Open this link in a new window


• View the NEWS results for 'Volume Imaging' (4).Open this link in a new window.
 
Further Reading:
  News & More:
3D-DOCTOR Tutorial
   by www.ablesw.com    
4D-Fueled AI with DCE-MRI Improves Breast Lesion Characterization
Friday, 26 February 2021   by www.diagnosticimaging.com    
Searchterm 'Image' was also found in the following services: 
spacer
News  (255)  Resources  (73)  Forum  (128)  
 
Alliance Pharmaceutical Corp.MRI Resource Directory:
 - Manufacturers -
 
www.allp.htm California-based research and development company. Alliance has several patents regarding 'microbubble' compositions such as Imagent® that are intended to enhance ultrasound imaging and Imagent GI as a gastrointestinal MRI contrast agent. Another product is Oxygent™, a synthetic 'blood substitute'.

MRI Contrast Agents:
Contact Information
MAIL
Alliance Pharmaceutical Corp.
6175 Lusk Blvd.
San Diego, CA 92121
USA
PHONE
+1-858-410-5200
FAX
+1-858-410-5161
spacer

• View the DATABASE results for 'Alliance Pharmaceutical Corp.' (2).Open this link in a new window

 
Further Reading:
  Basics:
Slumping MRI market prompts Alliance to halt GI contrast agent effort
Wednesday, 28 September 1994   by www.searchmedica.com    
MRI Resources 
MR Myelography - Mass Spectrometry - Colonography - MRI Physics - NMR - Claustrophobia
 
Array Spatial Sensitivity Encoding TechniqueInfoSheet: - Sequences - 
Intro, 
Overview, 
Types of, 
etc.
 
(ASSET) ASSET is a parallel imaging technique of the SENSE type (image domain reconstruction).
Each coil element is sensitivity encoded and the covered spatial zone is mapped. By reducing the field of view in the phase encoding gradient direction the scan time decreases, but this images of each coil element contain foldover artifacts. The sensitivity profiles of the elements are used to calculate unfolded images.

See also Sensitivity Encoding, Generalized Autocalibrating Partially Parallel Acquisition.
spacer

• View the DATABASE results for 'Array Spatial Sensitivity Encoding Technique' (4).Open this link in a new window

MRI Resources 
Service and Support - Mass Spectrometry - Software - Health - Journals -
 
previous      56 - 60 (of 453)     next
Result Pages : [1 2 3 4]  [5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 ... ]
 Random Page
 
Share This Page
FacebookTwitterLinkedIn

MR-TIP    
Community   
User
Pass
Forgot your UserID/Password ?    



How AI will impact MRI :
only diagnostics 
saving time 
reducing cost 
makes planning obsolete 
reduce human knowledge 
not at all 

Look
      Ups





MR-TIP.com uses cookies! By browsing MR-TIP.com, you agree to our use of cookies.

Magnetic Resonance - Technology Information Portal
Member of SoftWays' Medical Imaging Group - MR-TIP • Radiology-TIP • Medical-Ultrasound-Imaging • 
Copyright © 2003 - 2024 SoftWays. All rights reserved. [ 29 March 2024]
Terms of Use | Privacy Policy | Advertising
 [last update: 2024-02-26 03:41:00]