Unshielded Electric Components
 
Unshielded electric components in the magnet room will excite RF noise artifacts (interference) in different variations. RF 'buzz' will be seen over a range of frequencies on the images. The artifact runs in frequency encoding direction.
mri safety guidance
Image Guidance
Take care to use only MR compatible (special shielded) devices.

See also MR Compatibility.
spacer
 
Further Reading:
  News & More:
Electrical Noise in Intraoperative Magnetic Resonance Imaging reveals the intricacies of human brain – integrated consciousness with connectors to chilled universe
Sunday, 18 January 2009   by www.indiadaily.com    
MRI Resources 
Spectroscopy pool - PACS - Libraries - MRCP - Shielding - Health
 
Venetian Blind ArtifactInfoSheet: - Artifacts - 
Case Studies, 
Reduction Index, 
etc.MRI Resource Directory:
 - Artifacts -
 
Quick Overview
Artifact Information
NAME
Venetian blind
DESCRIPTION
Loss of signal of flowing blood
REASON
Saturation effect
HELP
Smaller 3D volume, multi chunk, TONE
The saturation effect of inflowing blood in 3D inflow MRA.
mri safety guidance
Image Guidance
Smaller 3D Volume or scans with e.g. tilt optimized nonsaturated excitation. In multi chunk scans TONE decreases this artifact or allows thicker chunks.
spacer

• View the DATABASE results for 'Venetian Blind Artifact' (3).Open this link in a new window

 
Further Reading:
  Basics:
Magnetic Resonance Imaging (MRI)
2003   by www.hull.ac.uk    
MRI Resources 
Jobs - Services and Supplies - Devices - Crystallography - Musculoskeletal and Joint MRI - Functional MRI
 
Zero Fill ArtifactInfoSheet: - Artifacts - 
Case Studies, 
Reduction Index, 
etc.MRI Resource Directory:
 - Artifacts -
 
Quick Overview
Artifact Information
NAME
Zero fill
DESCRIPTION
Zebra stripes or other anomalies
REASON
Signal changes
HELP
Surface coil, change the sequence
Missing or zero filled data in k-space can cause artifacts from anomalies to zebra stripes.
mri safety guidance
Image Guidance
Change the sequence parameters or try to use a surface coil. If the problem persists, it must be addressed by a service representative.
spacer

• View the DATABASE results for 'Zero Fill Artifact' (2).Open this link in a new window

 
Further Reading:
  Basics:
Zero-Fill Artifacts
   by www.mritutor.org    
Searchterm 'Image Guidance' was also found in the following service: 
spacer
News  (2)  
 
Zipper ArtifactInfoSheet: - Artifacts - 
Case Studies, 
Reduction Index, 
etc.MRI Resource Directory:
 - Artifacts -
 
Quick Overview
Artifact Information
NAME
Zipper, star
DESCRIPTION
Bands through image center
REASON
Hardware or software problems
HELP
Larger FOV, oversampling
Zipper artifacts appear as dashed lines. There are various causes for this MRI artifact.
Most of zipper artifacts result from inhomogeneities of the magnetic field caused by interferences with radio frequency from various sources ('your radio is working in the scanner room means your shielding is not working'). Software and equipment problems can also cause zipper lines in both directions.
mri safety guidance
Image Guidance
Scanning room door during the acquisition of images is closed, shielding is working, and all disturbing devices are removed?

See also Room Shielding, Active Shielding, Radio Frequency Shielding.
spacer
MRI Resources 
Stent - MRI Physics - Breast Implant - Most Wanted - Sequences - Services and Supplies
 
previous      51 - 54 (of 54)     
Result Pages : [1 2 3 4 5 6 7 8 9 10 11]
 Random Page
 
Share This Page
FacebookTwitterLinkedIn

MR-TIP    
Community   
User
Pass
Forgot your UserID/Password ?    



Personalized protocols (age, gender, body habitus, etc.) lead to :
more automated planning 
improved patient comfort 
better diagnostics 
optimized image quality 
nothing 

Look
      Ups





MR-TIP.com uses cookies! By browsing MR-TIP.com, you agree to our use of cookies.

Magnetic Resonance - Technology Information Portal
Member of SoftWays' Medical Imaging Group - MR-TIP • Radiology-TIP • Medical-Ultrasound-Imaging • 
Copyright © 2003 - 2024 SoftWays. All rights reserved. [ 19 April 2024]
Terms of Use | Privacy Policy | Advertising
 [last update: 2024-02-26 03:41:00]