Magnetic Resonance - Technology Information Portal Welcome to MRI Technology
Info
  Sheets

Out-
      side
 



 
 'Image Contrast Characteristics' 
SEARCH FOR    
 
  2 3 5 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Result : Searchterm 'Image Contrast Characteristics' found in 1 term [] and 5 definitions [], (+ 11 Boolean[] results
previous     16 - 17 (of 17)     
Result Pages : [1]  [2]  [3 4]
MRI Resources 
Claustrophobia - General - MRCP - Education - Service and Support - Coils
 
Sinerem®InfoSheet: - Contrast Agents - 
Intro, Overview, 
Characteristics, 
Types of, 
etc.MRI Resource Directory:
 - Contrast Agents -
 
Sinerem® is the brand name (same as Combidex®) for an ultrasmall superparamagnetic iron oxide (USPIO) to detect metastatic disease in lymph nodes. Metastatic nodes show less uptake of this MRI contrast agent, which results in less signal decrease and allows the differentiation of normal lymph nodes from normal-sized, metastatic nodes.
Lymph node imaging with Sinerem® is performed 24 to 36 hours after slow infusion. Normal lymph nodes turn black post contrast, namely on T2* weighted images. Metastatic lymph nodes remain unchanged in signal intensity.
Indication and Diseases: Cancer, Imaging for diagnosis, Lymphatic disorders.
See Ferumoxtran, and Classifications, Characteristics, etc.

Guerbet decided in 2007 to withdraw its Marketing Authorisation Application (MAA) for Sinerem.
Drug Information and Specification
NAME OF COMPOUND
Ferumoxtran, USPIO, AMI-227
CENTRAL MOIETY
Fe3+/Fe2+
CONTRAST EFFECT
r1=25, r2=160, B0=0.47T, r1=23.3, r2=48.9, B0=0.47T
PHARMACOKINETIC
Vascular, lymph v. hepatocyte (AG-USPIO)
CONCENTRATION
DOSAGE
2.6 mg Fe/kg
PREPARATION
Suspend in an isotonic glucose solution
INDICATION
MR angiography vascular, staging of RES-directed liver diseases, lymph nodes
DEVELOPMENT STAGE
-
DISTRIBUTOR
PRESENTATION
DO NOT RELY ON THE INFORMATION PROVIDED HERE, THEY ARE
NOT A SUBSTITUTE FOR THE ACCOMPANYING PACKAGE INSERT!
spacer
 
Further Reading:
  Basics:
The demise of Combidex - Sinerem
Wednesday, 24 March 2010   by www.wellsphere.com    
  News & More:
Ultrasmall Superparamagnetic Particles of Iron Oxide-enhanced in vivo MRI of human atherosclerotic plaques.(.pdf)
MRI Resources 
MRI Training Courses - Services and Supplies - Pregnancy - MR Guided Interventions - MR Myelography - General
 
Hepatobiliary Contrast AgentsInfoSheet: - Contrast Agents - 
Intro, Overview, 
Characteristics, 
Types of, 
etc.MRI Resource Directory:
 - Contrast Agents -
 
The characteristics of a hepatobiliary contrast agent are specific liver uptake and excretion via the biliary system. The paramagnetic substance (e.g. manganese, gadolinium) is taken up by normal hepatocytes. Diseased liver tissue did not include hepatocytes or their function is disturbed. Therefore, the signal of healthy liver tissue increases on T1 weighted sequences, but not in the liver lesions.
Another type of liver imaging contrast agent is superparamagnetic iron oxide. These particles accumulate in the reticuloendothelial system (RES) of the liver, and darken the healthy liver tissue in T2 weighted images. RES cells (including Kupffer cells) are existing in healthy liver tissue, in altered tissue with reduced RES activity or without RES cells the contrast agent concentration is also low or not existing, which improves the liver to lesion contrast.
Benefits of hepatobiliary contrast agents:
•
Liver lesions (e.g., tumor, metastases, haemangioma etc.) are better detectable and to characterize.
•
These contrast agents are useful to analyze and evaluate the liver function (in cases of diffuse liver diseases e.g., cirrhosis).
•
Imaging of the gallbladder and biliary system is improved.

Differences of a hepatobiliary contrast agent compared with a targeted contrast agent for Kupffer cells:
•
The higher number of hepatocytes than Kupffer cells improves the uptake effectiveness of the contrast agent.
•
Hepatobiliary contrast agents enable a better opacification of the biliary ducts and the gallbladder caused by the biliary excretion.
•
Hepatobiliary contrast media are fast excreted agents. RES targeted contrast agents remain longer in the body, a fact that can increase possible side effects.

See also Superparamagnetic Contrast Agents, Hepatobiliary Chelates, Liver Imaging, Endoremâ„¢, Primovistâ„¢, and Classifications, Characteristics, etc.

See also the related poll result: 'The development of contrast agents in MRI is'
spacer

• View the DATABASE results for 'Hepatobiliary Contrast Agents' (11).Open this link in a new window

 
Further Reading:
  Basics:
Contrast MRI Best at Finding Liver Trouble - But Timing Matters
Sunday, 6 March 2011   by www.searchmedica.com    
  News & More:
Iron overload: accuracy of in-phase and out-of-phase MRI as a quick method to evaluate liver iron load in haematological malignancies and chronic liver disease
Friday, 1 June 2012   by www.ncbi.nlm.nih.gov    
EMA's final opinion confirms restrictions on use of linear gadolinium agents in body scans
Friday, 21 July 2017   by www.ema.europa.eu    
MAGNETIC RESONANCE IMAGING OF FOCAL LIVER LESIONS(.pdf)
2002
MRI Resources 
Implant and Prosthesis pool - Health - Non-English - MR Guided Interventions - Pacemaker - Implant and Prosthesis
 
previous      16 - 17 (of 17)     
Result Pages : [1]  [2]  [3 4]
 Random Page
 
Share This Page
FacebookTwitterLinkedIn

MR-TIP    
Community   
User
Pass
Forgot your UserID/Password ?    



New acceleration techniques will :
reduce scan times 
cause artifacts 
increase expenses 
be useful if you have a lot of experience 
doesn't do much 
never heard of 

Look
      Ups





MR-TIP.com uses cookies! By browsing MR-TIP.com, you agree to our use of cookies.

Magnetic Resonance - Technology Information Portal
Member of SoftWays' Medical Imaging Group - MR-TIP • Radiology-TIP • Medical-Ultrasound-Imaging • 
Copyright © 2003 - 2024 SoftWays. All rights reserved. [ 24 April 2024]
Terms of Use | Privacy Policy | Advertising
 [last update: 2024-02-26 03:41:00]