Magnetic Resonance - Technology Information Portal Welcome to MRI Technology
Info
  Sheets

Out-
      side
 



 
 'Gating' 
SEARCH FOR    
 
  2 3 5 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Result : Searchterm 'Gating' found in 4 terms [] and 63 definitions []
previous     41 - 45 (of 67)     next
Result Pages : [1]  [2 3 4 5 6 7 8 9 10 11 12 13 14]
Searchterm 'Gating' was also found in the following services: 
spacer
News  (4)  Resources  (2)  Forum  (1)  
 
MAGNETOM Avanto™InfoSheet: - Devices -
Intro, 
Types of Magnets, 
Overview, 
etc.MRI Resource Directory:
 - Devices -
 
test.med.siemens.com/magnetom/rsna_chicago_2003/tim/avanto/index.php From Siemens Medical Systems; MAGNETOM Avanto with Tim - Total imaging matrix technology. For true whole-body anatomical coverage. For ultra-fast image acquisition. Aids the physician in fast and precise evaluation of systemic diseases like colon cancer, metastasis imaging, vessel diseases, and preventional exams. For claustrophobic patients, MAGNETOM Avanto enables feetfirst exams for nearly all MR procedures. For obese patients, MAGNETOM Avanto supports up to 200 kg (400 lbs), without table movement restrictions. The AudioComfort technology enables up to a 30 dB(A) acoustic noise reduction, that means nearly all clinical routine sequences are running under 99 dB(A).
Device Information and Specification
CLINICAL APPLICATION
Whole body
CONFIGURATION
Compact short bore
Body, Tim [32 x 8], Tim [76 x18], Tim [76 coil elements with up to 32 RF channels]
Yes/SVS or CSI opt.
SYNCHRONIZATION
ECG/peripheral, respiratory gating
PULSE SEQUENCES
GRE, IR, FIR, STIR, TrueIR/FISP, FSE, FLAIR, MT, SS-FSE, MT-SE, MTC, MSE, EPI, 3D DESS//CISS/PSIF, GMR
IMAGING MODES
Single, multislice, volume study, multi angle, multi oblique
FOV
0.5 cm - 50 cm
Min 2D/3D: 0.1/0.05 mm
1024 x 1024 full screen display
MEASURING MATRIX
64 x 64 to 1024 x 1024
10 micrometer in plane
BORE DIAMETER
or W x H
60 cm
POWER REQUIREMENTS
380/400/420/440/480 V
STRENGTH
up to 45 mT/m
5-GAUSS FRINGE FIELD
2.5 m / 4.0 m
Passive, act.; 1st order std./2nd opt.
spacer
 
• Related Searches:
    • MRI Equipment
    • Device
    • Hardware
    • High Field MRI
    • Low Field MRI
 
Further Reading:
  Basics:
12 510(k) MAGNETOM Avanto System(.pdf)
   by www.accessdata.fda.gov    
  News & More:
Obesity May Influence Imaging Diagnosis
Wednesday, 22 December 2004   by www.hospimedica.com    
Searchterm 'Gating' was also found in the following services: 
spacer
Radiology  (5) Open this link in a new windowUltrasound  (7) Open this link in a new window
MAGNETOM C™InfoSheet: - Devices -
Intro, 
Types of Magnets, 
Overview, 
etc.MRI Resource Directory:
 - Devices -
 
www.medical.siemens.com From Siemens Medical Systems;
A new, powerful, compact player in MRI. For both, patients and health care professionals, the mid-field has realized a giant step to cost efficient quality care. Obese patients and people with claustrophobia appreciate the comfortable side loading. The smallest pole diameter - 137 cm (54 inches) allows for optimal patient comfort.
Device Information and Specification
CLINICAL APPLICATION
Whole body
CONFIGURATION
C-shaped open MRI
Multi channel imaging, CP Head//Neck Array Coil, Body/Spine Array Coil, large, Transmit Coil
SYNCHRONIZATION
ECG/peripheral: Optional/yes, respiratory gating
PULSE SEQUENCES
SE, FLASH, FISP, IR, FIR, STIR, TrueIR/FISP, FSE, MT, SS-FSE, MT-SE, MTC, MSE, EPI, PSIF
IMAGING MODES
Single, multislice, volume study, multi angle, multi oblique
TR
Min. TR 2.81 ms
TE
Min. TE 0.98 ms
512 x 512 full screen display
MEASURING MATRIX
64 x 64 to 512 x 512
FOV
0.5 - 40 cm
MAGNET TYPE
Permanent
BORE DIAMETER
or W x H
41 cm vertical gap distance
MAGNET WEIGHT
16000 kg
H*W*D
233 x 206 x 160 cm
STRENGTH
24 mT/m
5-GAUSS FRINGE FIELD
2.2 m / 2.2 m
Passive and active
spacer

• View the DATABASE results for 'MAGNETOM C™' (2).Open this link in a new window

 
Further Reading:
  Basics:
Section 2: 510(k) Summary, MAGNETOM C! System Classification Name: Magnetic Resonance Diagnostic(.pdf)
   by www.accessdata.fda.gov    
MRI Resources 
Knee MRI - Claustrophobia - Abdominal Imaging - Supplies - Case Studies - Safety Training
 
MAGNETOM Harmony™InfoSheet: - Devices -
Intro, 
Types of Magnets, 
Overview, 
etc.MRI Resource Directory:
 - Devices -
 
www.med.siemens.com/med/d/gg/mr/products/harmony.htm From Siemens Medical Systems;
the MAGNETOM Harmony system is a high-performance MR imaging system based on 1.0 T field strength for best clinical routine MRI. It combines patient-friendly design features with the benefits of short imaging time, high anatomical resolution, and highest productivity.
Device Information and Specification
CLINICAL APPLICATION
Whole body
CONFIGURATION
Compact
Body, head, spine, knee, neck, TMJ, extremity, breast, shoulder, others
Yes/SVS opt.
SYNCHRONIZATION
ECG/peripheral, respiratory gating
PULSE SEQUENCES
GRE, IR, FIR, STIR, TrueIR/FISP, FSE, FLAIR, MT, SS-FSE, MT-SE, MTC, MSE, EPI, GMR, fat/water sat./exc.
IMAGING MODES
Single, multislice, volume study, multi angle, multi oblique
TR
2.4 msec std.; 2.0 opt.; 1.8 w/ 30mT/m at 256matrix
TE
1.1 msec std.; 0.9 opt.; 0.78 w/30 mT/m at 256matrix
SINGLE/MULTI SLICE
178 images/sec at 256 x 256 at 100% FOV
FOV
0.5 cm - 50 cm
Min 2D/3D: 0.1/0.05 mm
1024 x 1024 full screen display
MEASURING MATRIX
64 x 64 to 1024 x 1024
21 micrometer in plane, 11 micrometer optional
BORE DIAMETER
or W x H
60 cm
MAGNET WEIGHT (gantry included)
3500kg, 5000kg in operation
DIMENSION H*W*D (gantry included)
POWER REQUIREMENTS
380/400/420/440/480 V
COOLING SYSTEM TYPE
Single cryogen, 2 stage refrig.
CRYOGEN USE
Liquid He
STRENGTH
20/35 mT/m standard, 30/52 opt.
5-GAUSS FRINGE FIELD
2.5 m / 3.9 m
Passive, act.; 1st order std./2nd opt.
spacer

• View the DATABASE results for 'MAGNETOM Harmony™' (2).Open this link in a new window

 
Further Reading:
  Basics:
Harmony Brochure(.pdf)
Searchterm 'Gating' was also found in the following services: 
spacer
News  (4)  Resources  (2)  Forum  (1)  
 
MAGNETOM Sonata™InfoSheet: - Devices -
Intro, 
Types of Magnets, 
Overview, 
etc.MRI Resource Directory:
 - Devices -
 
www.med.siemens.com/med/d/gg/mr/products/sonata.html From Siemens Medical Systems;
while older navigator techniques take up to 40 minutes to create, the high performance of the MAGNETOM Sonata system enables 'complete examinations in less than 15 minutes'. It creates a new standard of diagnostic confidence and moves Cardiac MR from the research setting into routine clinical practice.
Device Information and Specification
CLINICAL APPLICATION
Whole body
CONFIGURATION
Compact
Yes/SVS or CSI opt.
SYNCHRONIZATION
ECG/peripheral, respiratory gating
PULSE SEQUENCES
GRE, IR, FIR, STIR, TrueIR/FISP, FSE, FLAIR, MT, SS-FSE, MT-SE, MTC, MSE, EPI, 3D DESS//CISS/PSIF, GMR
IMAGING MODES
Single, multislice, volume study, multi angle, multi oblique
TR
1.5 msec at 256matrix
TE
0.58 msec at 256matrix
SINGLE/MULTI SLICE
178 images/sec at 256 x 256 at 100% FOV
0.5 cm - 40 cm
Min 2D/3D: 0.1/0.05 mm
1024 x 1024 full screen display
MEASURING MATRIX
64 x 64 to 1024 x 1024
PIXEL INTENSITY
10 micrometer in plane
60 cm
MAGNET WEIGHT
4050kg, 5500kg in operation
H*W*D
236 x 215 x 160 cm
POWER REQUIREMENTS
380/400/420/440/480 V
COOLING SYSTEM TYPE
Single cryogen, 2 stage refrig.
Liquid He
STRENGTH
40/70 mT/m
5-GAUSS FRINGE FIELD
2.5 m / 4.0 m
Passive, act.; 1st order std./2nd opt.
spacer

• View the DATABASE results for 'MAGNETOM Sonata™' (2).Open this link in a new window

Searchterm 'Gating' was also found in the following services: 
spacer
Radiology  (5) Open this link in a new windowUltrasound  (7) Open this link in a new window
MAGNETOM Symphony™InfoSheet: - Devices -
Intro, 
Types of Magnets, 
Overview, 
etc.MRI Resource Directory:
 - Devices -
 
www.med.siemens.com/med/d/gg/mr/products/symphony1.html From Siemens Medical Systems;
with the introduction of this system, it is possible to perform contrast MR angiography for abdominal, thoracic and neck vessels from the origins to the circle of Willis. The system also has many newer features including functional imaging, spectroscopy, advanced body, ortho- and neuroimaging.
Device Information and Specification
CLINICAL APPLICATION
Whole body
CONFIGURATION
Compact
Yes/SVS or CSI opt.
SYNCHRONIZATION
ECG/peripheral, respiratory gating
PULSE SEQUENCES
GRE, IR, FIR, STIR, TrueIR/FISP, FSE, FLAIR, MT, SS-FSE, MT-SE, MTC, MSE, EPI, GMR, fat/water sat./exc.
IMAGING MODES
Single, multislice, volume study, multi angle, multi oblique
TR
2.4 msec std.; 2.0 opt.; 1.8 w/30 mT/m at 256matrix
TE
1.1 msec std.; 0.9 opt.; 0.78 w/30 mT/m at 256matrix
SINGLE/MULTI SLICE
178 images/sec at 256 x 256 at 100% FOV
0.5 cm - 50 cm
Min 2D/3D: 0.1/0.05 mm
1024 x 1024 full screen display
MEASURING MATRIX
64 x 64 to 1024 x 1024
PIXEL INTENSITY
21 micrometer in plane, 11 micrometer optional
60 cm
MAGNET WEIGHT
4050kg, 5500kg in operation
H*W*D
236 x 215 x 160 cm w/covers
POWER REQUIREMENTS
380/400/420/440/480 V
COOLING SYSTEM TYPE
Single cryogen, 2 stage refrig.
Liquid He
STRENGTH
20/35 mT/m standard, 30/52 opt.
5-GAUSS FRINGE FIELD
2.5 m / 4.0 m
Passive, act.; 1st order std./2nd opt.
spacer

• View the DATABASE results for 'MAGNETOM Symphony™' (2).Open this link in a new window

 
Further Reading:
  Basics:
Symphony Brochure(.pdf)
MRI Resources 
IR - Journals - Corporations - Equipment - Mobile MRI - Implant and Prosthesis
 
previous      41 - 45 (of 67)     next
Result Pages : [1]  [2 3 4 5 6 7 8 9 10 11 12 13 14]
 Random Page
 
Share This Page
FacebookTwitterLinkedIn

MR-TIP    
Community   
User
Pass
Forgot your UserID/Password ?    



MRI is trending to low field magnets :
reduced costs will lead to this change 
AI will close the gap to high field 
only in remote areas 
is only temporary 
never 

Look
      Ups





MR-TIP.com uses cookies! By browsing MR-TIP.com, you agree to our use of cookies.

Magnetic Resonance - Technology Information Portal
Member of SoftWays' Medical Imaging Group - MR-TIP • Radiology-TIP • Medical-Ultrasound-Imaging • 
Copyright © 2003 - 2024 SoftWays. All rights reserved. [ 28 March 2024]
Terms of Use | Privacy Policy | Advertising
 [last update: 2024-02-26 03:41:00]