Magnetic Resonance - Technology Information Portal Welcome to MRI Technology
Info
  Sheets

Out-
      side
 



 
 'Gadolinium' 
SEARCH FOR    
 
  2 3 5 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Result : Searchterm 'Gadolinium' found in 4 terms [] and 62 definitions []
previous     46 - 50 (of 66)     next
Result Pages : [1]  [2 3 4 5 6 7 8 9 10 11 12 13 14]
Searchterm 'Gadolinium' was also found in the following services: 
spacer
News  (36)  Resources  (6)  Forum  (17)  
 
GdDOTA-4AmPInfoSheet: - Contrast Agents - 
Intro, Overview, 
Characteristics, 
Types of, 
etc.
 
Short name: GdDOTA-4AmP, central moiety: Gd
A pH-sensitive gadolinium-based contrast agent under development to image tissue pH in vivo by MRI.
spacer
Searchterm 'Gadolinium' was also found in the following service: 
spacer
Radiology  (1) Open this link in a new window
Hepatobiliary ChelatesInfoSheet: - Contrast Agents - 
Intro, Overview, 
Characteristics, 
Types of, 
etc.
 
Hepatobiliary chelates used in MRI are paramagnetic contrast agents consisting of a metal ion bound to an organic ligand. Paramagnetic metal ions such as gadolinium improve the MRI signal, but the toxicity of these uncomplexed metal ions makes the use of a chelate to bind the metal ion essential. Due to the hepatocyte uptake of this chelate complex, the different contrast between normal parenchyma and liver lesions improves the detection and characterization of specific diseases. In addition, the hepatobiliary excretion allows the assessment of the hepatobiliary system.
Chelates for hepatobiliary imaging: MultiHance® (Gadobenate Dimeglumine), Teslascan® (Mangafodipir Trisodium), Gd-HIDA, Cr-HIDA, and Fe-EHPG IronIII or other derivatives.

See also Hepatobiliary Contrast Agents, Liver Imaging.
spacer

• View the DATABASE results for 'Hepatobiliary Chelates' (6).Open this link in a new window

MRI Resources 
Online Books - NMR - Patient Information - Quality Advice - Research Labs - Collections
 
Hepatobiliary Contrast AgentsInfoSheet: - Contrast Agents - 
Intro, Overview, 
Characteristics, 
Types of, 
etc.MRI Resource Directory:
 - Contrast Agents -
 
The characteristics of a hepatobiliary contrast agent are specific liver uptake and excretion via the biliary system. The paramagnetic substance (e.g. manganese, gadolinium) is taken up by normal hepatocytes. Diseased liver tissue did not include hepatocytes or their function is disturbed. Therefore, the signal of healthy liver tissue increases on T1 weighted sequences, but not in the liver lesions.
Another type of liver imaging contrast agent is superparamagnetic iron oxide. These particles accumulate in the reticuloendothelial system (RES) of the liver, and darken the healthy liver tissue in T2 weighted images. RES cells (including Kupffer cells) are existing in healthy liver tissue, in altered tissue with reduced RES activity or without RES cells the contrast agent concentration is also low or not existing, which improves the liver to lesion contrast.
Benefits of hepatobiliary contrast agents:
•
Liver lesions (e.g., tumor, metastases, haemangioma etc.) are better detectable and to characterize.
•
These contrast agents are useful to analyze and evaluate the liver function (in cases of diffuse liver diseases e.g., cirrhosis).
•
Imaging of the gallbladder and biliary system is improved.

Differences of a hepatobiliary contrast agent compared with a targeted contrast agent for Kupffer cells:
•
The higher number of hepatocytes than Kupffer cells improves the uptake effectiveness of the contrast agent.
•
Hepatobiliary contrast agents enable a better opacification of the biliary ducts and the gallbladder caused by the biliary excretion.
•
Hepatobiliary contrast media are fast excreted agents. RES targeted contrast agents remain longer in the body, a fact that can increase possible side effects.

See also Superparamagnetic Contrast Agents, Hepatobiliary Chelates, Liver Imaging, Endoremâ„¢, Primovistâ„¢, and Classifications, Characteristics, etc.

See also the related poll result: 'The development of contrast agents in MRI is'
spacer

• View the DATABASE results for 'Hepatobiliary Contrast Agents' (11).Open this link in a new window

 
Further Reading:
  Basics:
Contrast MRI Best at Finding Liver Trouble - But Timing Matters
Sunday, 6 March 2011   by www.searchmedica.com    
  News & More:
Iron overload: accuracy of in-phase and out-of-phase MRI as a quick method to evaluate liver iron load in haematological malignancies and chronic liver disease
Friday, 1 June 2012   by www.ncbi.nlm.nih.gov    
EMA's final opinion confirms restrictions on use of linear gadolinium agents in body scans
Friday, 21 July 2017   by www.ema.europa.eu    
MAGNETIC RESONANCE IMAGING OF FOCAL LIVER LESIONS(.pdf)
2002
Searchterm 'Gadolinium' was also found in the following services: 
spacer
News  (36)  Resources  (6)  Forum  (17)  
 
High Field MRI
 
The principal advantage of MRI at high field is the increase in signal to noise ratio. This can be used to improve anatomic and/or temporal resolution and reduce scan time while preserving image quality. MRI devices for whole body imaging for human use are available up to 3 tesla (3T). Functional MRI (fMRI) and MR spectroscopy (MRS) benefit significantly. In addition, 3T machines have a great utility in applications such as TOF MRA and DTI. Higher field strengths are used for imaging of small parts of the body or scientific animal experiments. Higher contrast may permit reduction of gadolinium doses and, in some cases, earlier detection of disease.
Using high field MRI//MRS, the RF-wavelength and the dimension of the human body complicating the development of MR coils. The absorption of RF power causes heating of the tissue. The energy deposited in the patient's tissues is fourfold higher at 3T than at 1.5T. The specific absorption rate (SAR) induced temperature changes of the human body are the most important safety issue of high field MRI//MRS.
Susceptibility and chemical shift dispersion increase like T1, therefore high field MRI occasionally exhibits imaging artifacts. Most are obvious and easily recognized but some are subtle and mimic diseases. A thorough understanding of these artifacts is important to avoid potential pitfalls. Some imaging techniques or procedures can be utilized to remove or identify artifacts.

See also Diffusion Tensor Imaging.

See also the related poll result: 'In 2010 your scanner will probably work with a field strength of'
Medical-Ultrasound-Imaging.comMagnetic Resonance Guided Focused Ultrasound,  High Intensity Focused Ultrasound
spacer

• View the DATABASE results for 'High Field MRI' (16).Open this link in a new window


• View the NEWS results for 'High Field MRI' (9).Open this link in a new window.
 
Further Reading:
  Basics:
Next-generation 7 T scanner ramps the resolution of brain MR imaging
Wednesday, 17 January 2024   by physicsworld.com    
A paired dataset of T1- and T2-weighted MRI at 3 Tesla and 7 Tesla
Thursday, 27 July 2023   by www.nature.com    
CLINICAL WHOLE BODY MRI AT 3.0 T(.pdf)
2001
Musculoskeletal MRI at 3.0 T: Relaxation Times and Image Contrast
Sunday, 1 August 2004   by www.ajronline.org    
  News & More:
How safe is 7T MRI for patients with neurosurgical implants?
Thursday, 17 November 2022   by healthimaging.com    
Impact of Magnetic Field Inhomogeneity on the Quality of Magnetic Resonance Images and Compensation Techniques: A Review
Saturday, 1 October 2022   by www.dovepress.com    
7-T clinical MRI of the shoulder in patients with suspected lesions of the rotator cuff
Friday, 7 February 2020   by eurradiolexp.springeropen.com    
A 100-hour MRI scan captured the most detailed look yet at a whole human brain
Monday, 8 July 2019   by www.sciencenews.or    
T2-Weighted Liver MRI Using the MultiVane Technique at 3T: Comparison with Conventional T2-Weighted MRI
Friday, 16 October 2015   by www.ncbi.nlm.nih.gov    
Ultra-high-field MRI reveals language centres in the brain in much more detail
Tuesday, 28 October 2014   by medicalxpress.com    
Turbo-FLASH Based Arterial Spin Labeled Perfusion MRI at 7 T
Thursday, 20 June 2013   by www.plosone.org    
High-Resolution, Spin-Echo BOLD, and CBF fMRI at 4 and 7 T(.pdf)
October 2002   by otg.downstate.edu    
Vascular Filters of Functional MRI: Spatial Localization Using BOLD and CBV Contrast
Searchterm 'Gadolinium' was also found in the following service: 
spacer
Radiology  (1) Open this link in a new window
Ionic Intravenous Contrast AgentsInfoSheet: - Contrast Agents - 
Intro, Overview, 
Characteristics, 
Types of, 
etc.MRI Resource Directory:
 - Contrast Agents -
 
Intravenous contrast agents used in MRI are distributed in the extracellular spaces of the body before being excreted. In this sense they are similar to iodinated X-ray contrast media. However, contrast agents used for MRI are quite different from conventional radiographic contrast media in structure and function and there is no known cross sensitivity between these types of contrast agents. Common MRI contrast agents use metal ions (e.g., gadolinium or manganese) complexed with organic molecules.
Gd-DTPA, an ionic linear molecule complex (gadopentetate dimeglumine) was the first marketed MRI contrast agent. Although the osmolality of this substances can be relatively high (up to 1940 mOsm/kg H2O) compared with plasma, adverse reactions and side effects are very rare. The used doses are smaller compared with radiographic contrast media.

See also Nonionic Intravenous Contrast Agents, Dotarem®, and Magnevist®.
 
Images, Movies, Sliders:
 Breast MRI Images T1 Pre - Post Contrast  Open this link in a new window
      
 
spacer

• View the DATABASE results for 'Ionic Intravenous Contrast Agents' (5).Open this link in a new window

 
Further Reading:
  Basics:
FDA Approves First Macrocyclic and Ionic Gadolinium-Contrast Agent for MRI
Friday, 22 March 2013   by www.itnonline.com    
  News & More:
Spurious Hypocalcemia After Omniscan- or OptiMARK-Enhanced Magnetic Resonance Imaging: An Algorithm for Minimizing a False-Positive Laboratory Value
   by arpa.allenpress.com    
MRI Resources 
Quality Advice - MRA - Contrast Agents - Nerve Stimulator - Hospitals - Safety Products
 
previous      46 - 50 (of 66)     next
Result Pages : [1]  [2 3 4 5 6 7 8 9 10 11 12 13 14]
 Random Page
 
Share This Page
FacebookTwitterLinkedIn

MR-TIP    
Community   
User
Pass
Forgot your UserID/Password ?    



How AI will impact MRI :
only diagnostics 
saving time 
reducing cost 
makes planning obsolete 
reduce human knowledge 
not at all 

Look
      Ups





MR-TIP.com uses cookies! By browsing MR-TIP.com, you agree to our use of cookies.

Magnetic Resonance - Technology Information Portal
Member of SoftWays' Medical Imaging Group - MR-TIP • Radiology-TIP • Medical-Ultrasound-Imaging • 
Copyright © 2003 - 2024 SoftWays. All rights reserved. [ 24 April 2024]
Terms of Use | Privacy Policy | Advertising
 [last update: 2024-02-26 03:41:00]