 'Fast Spin Echo' 
SEARCH FOR    
 
  2 3 5 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Result : Searchterm 'Fast Spin Echo' found in 5 terms [] and 28 definitions []
previous     6 - 10 (of 33)     next
Result Pages : [1]  [2 3 4 5 6 7]
Searchterm 'Fast Spin Echo' was also found in the following service: 
spacer
Forum  (3)  
 
ENCORE 0.5T™InfoSheet: - Devices -
Intro, 
Types of Magnets, 
Overview, 
etc.MRI Resource Directory:
 - Devices -
 
www.isoltech.co.kr/english/product/05t.htm 'MRI system is not an expensive equipment anymore. ENCORE developed by ISOL Technology is a low cost MRI system with the advantages like of the 1.0T MRI scanner. Developed specially for the overseas market, the ENCORE is gaining popularity in the domestic market by medium sized hospitals.
Due to the optimum RF and Gradient application technology. ENCORE enables to obtain high resolution imaging and 2D/3D Angio images which was only possible in high field MR systems.'
- Less consumption of the helium gas due to the ultra-lightweight magnet specially designed and manufactured for ISOL. - Cost efficiency MR system due to air cooling type (equivalent to permanent magnetic). - Patient processing speed of less than 20 minutes.'
Device Information and Specification
CLINICAL APPLICATION
Whole body
CONFIGURATION
Short bore compact
Head, C-spine, L-spine, TMJ, Knee, Shoulder, General purpose, Phased Array System: 4 digital receiver channels (Up to 12 channels)
SYNCHRONIZATION
ECG/peripheral: Optional/yes, respiratory gating
SINGLE/MULTI SLICE
Image reconstruction time (2562 ) : 0.02 s
FOV
40 cm
BORE DIAMETER
or W x H
58 cm diameter
MAGNET WEIGHT
3200 kg
H*W*D
200 x 168 x 187 cm
COOLING SYSTEM TYPE
Air-cooled coil and amplifier
CRYOGEN USE
0.05 L/hr helium
STRENGTH
15 mT/m
5-GAUSS FRINGE FIELD
2.3 m / 3.1 m
Passive and active
spacer
 
• Related Searches:
    • Superconducting Magnet
    • Low Field MRI
    • Echelon™ 1.5T
    • MRI
    • Coil
MRI Resources 
Collections - MRCP - Quality Advice - Jobs pool - Examinations - MRI Technician and Technologist Jobs
 
Echo Spacing
 
Echo spacing is the distance in time between the echoes in multiple echo sequences like, e.g. echo planar imaging, fast spin echo. A short echo space produces compact sequence timing and less image artifacts. The shorter the rise time, the faster the gradients and therefore the echo spacing. Gradients with a shorter echo spacing will have a better resolution and more slices per TR.

See also Fast Spin Echo.
spacer

• View the DATABASE results for 'Echo Spacing' (6).Open this link in a new window

 
Further Reading:
  Basics:
Fast Spin Echo(.pdf)
Tuesday, 24 January 2006   by www.81bones.net    
MRI Resources 
Non-English - Collections - Pediatric and Fetal MRI - MRI Technician and Technologist Jobs - Raman Spectroscopy - Research Labs
 
Multi Echo Imaging
 
Multi echo imaging sequences use a series of echoes acquired as a train following after a single excitation pulse. Multiple symmetrical or asymmetrical echoes can be acquired, typically T2 weighted. In spin echo imaging, each echo is formed by a 180° pulse, but also a FSE (TSE, RARE) or EPI sequence can be used. As a difference to a normal fast spin echo sequence, in multi echo imaging, separate images are produced from each echo of the train with different T2 weightings. The signal height reduces with transverse relaxation. This drop in signal can be used to calculate a pure T2 image.

See also Fast Spin Echo.
spacer

• View the DATABASE results for 'Multi Echo Imaging' (3).Open this link in a new window

 
Further Reading:
  Basics:
A very simple, robust and fast method for estimating and displaying average time constants of T2 decays from multiecho MRI images using color intensity projections
   by arxiv.org    
What MRI Sequences Produce the Highest Specific Absorption Rate (SAR), and Is There Something We Should Be Doing to Reduce the SAR During Standard Examinations?
Thursday, 16 April 2015   by www.ajronline.org    
  News & More:
Automatic Mapping Extraction from Multiecho T2-Star Weighted Magnetic Resonance Images for Improving Morphological Evaluations in Human Brain
Wednesday, 5 June 2013   by www.hindawi.com    
RARE
Monday, 3 December 2012   by www2.warwick.ac.uk    
Searchterm 'Fast Spin Echo' was also found in the following service: 
spacer
Forum  (3)  
 
Rapid Acquisition with Refocused EchoesInfoSheet: - Sequences - 
Intro, 
Overview, 
Types of, 
etc.MRI Resource Directory:
 - Sequences -
 
(RARE) If the image lines from multiple echoes are used for the same image, this results in the RARE pulse sequence. The sequence is similar to fast spin echo.

See Fast Spin Echo.
spacer

• View the DATABASE results for 'Rapid Acquisition with Refocused Echoes' (2).Open this link in a new window

 
Further Reading:
  Basics:
RARE
Monday, 3 December 2012   by www2.warwick.ac.uk    
MRI Resources 
Fluorescence - Mass Spectrometry - Jobs - Contrast Enhanced MRI - Absorption and Emission - Homepages
 
Turbo Inversion RecoveryInfoSheet: - Sequences - 
Intro, 
Overview, 
Types of, 
etc.MRI Resource Directory:
 - Sequences -
 
( TIR / TIRM / IR-TSE - Inversion Recovery Turbo Spin Echo / FIR - Fast Inversion Recovery)
A turbo / fast spin echo sequence with long TI for fluid suppression (FLAIR) or with short TI for fat suppression (STIR). This sequence allows for a true inversion recovery display that shows the arithmetic sign of the signal.
TIRM means a turboIR with a magnitude display.

See also Inversion Recovery, Inversion Recovery Sequence and Fast Spin Echo.
spacer
 
Further Reading:
  News & More:
Accurate T1 Quantification Using a Breath-hold Inversion Recovery TrueFISP Sequence
2003   by rsna2003.rsna.org    
MRI Resources 
Jobs pool - Nerve Stimulator - Safety Products - MRI Physics - Raman Spectroscopy - IR
 
previous      6 - 10 (of 33)     next
Result Pages : [1]  [2 3 4 5 6 7]
 Random Page
 
Share This Page
FacebookTwitterLinkedIn

MR-TIP    
Community   
User
Pass
Forgot your UserID/Password ?    



MRI is trending to low field magnets :
reduced costs will lead to this change 
AI will close the gap to high field 
only in remote areas 
is only temporary 
never 

Look
      Ups





MR-TIP.com uses cookies! By browsing MR-TIP.com, you agree to our use of cookies.

Magnetic Resonance - Technology Information Portal
Member of SoftWays' Medical Imaging Group - MR-TIP • Radiology-TIP • Medical-Ultrasound-Imaging • 
Copyright © 2003 - 2024 SoftWays. All rights reserved. [ 16 April 2024]
Terms of Use | Privacy Policy | Advertising
 [last update: 2024-02-26 03:41:00]