Spin Quantum Number
 
(I) Property of all nuclei related to the largest measurable component of the nuclear angular momentum. Non-zero values of nuclear angular momentum are quantized (fixed) as integral or half-integral multiples of (h/2p), where h is Planck's constant. The number of possible energy levels for a given nucleus in a fixed magnetic field is equal to 2I + 1. Similarly, an unpaired electron has a spin of 1/2 and two possible energy levels.
spacer
 
• Related Searches:
    • Multiple Quantum Coherence
    • Hydrogen Density
    • Magnetization Vector
    • Magnetic Resonance Imaging MRI
    • Spin
 
Further Reading:
  Basics:
Electron Spin
   by hyperphysics.phy-astr.gsu.edu    
  News & More:
Quantum Numbers and the Periodic Table
   by dwb4.unl.edu    
Searchterm 'Energy' was also found in the following services: 
spacer
Radiology  (79) Open this link in a new windowUltrasound  (50) Open this link in a new window
Spin Spin Coupling
 
NMR spectral lines may consist of groups of lines called multiplets. This multiplet structure is caused by interactions between nuclei that split the NMR energy levels and result in the observation of multiple allowed transitions separated by an amount of energy related to J, the spin spin coupling constant. These interactions are called spin spin coupling.
spacer

• View the DATABASE results for 'Spin Spin Coupling' (10).Open this link in a new window

 
Further Reading:
  Basics:
Spin Spin Coupling:The splitting of NMR Signals
   by iis.dmhcsm.edu.hk    
MRI Resources 
Spectroscopy - Claustrophobia - MRI Physics - MR Myelography - Manufacturers - Fluorescence
 
Superparamagnetism
 
Superparamagnetism occurs when the material is composed of very small crystallites (1-10 nm). In this case, even though the temperature is below the Curie or NĆ©el temperature and the thermal energy is not sufficient to overcome the coupling forces between neighboring atoms, the thermal energy is sufficient to change the direction of magnetization of the entire crystallite. The resulting fluctuations in the direction of magnetization cause the magnetic field to average to zero. The material behaves in a manner similar to paramagnetism, except that instead of each individual atom being independently influenced by an external magnetic field, the magnetic moment of the entire crystallite tends to align with the magnetic field.
In MRI superparamagnetic iron oxide is used as a contrast agent.

See also magnetism, ferromagnetism, paramagnetism, and diamagnetism.
spacer

• View the DATABASE results for 'Superparamagnetism' (6).Open this link in a new window

 
Further Reading:
  Basics:
Superparamagnetism
   by en.wikipedia.org    
  News & More:
Imagion (ASX:IBX) share price up 1,166% in a year pursuing adiation-freeā„¢ cancer tech
Monday, 29 March 2021   by www.fool.com.au    
Searchterm 'Energy' was also found in the following services: 
spacer
News  (21)  Resources  (6)  Forum  (4)  
 
Absorbed Dose
 
This dose means the RF power absorbed per unit of mass of an object, and is measured in watts per kilogram (W/kg).
The absorbed dose is dependent on the duty cycle and transmitter-coil type and increases with field strength, radio frequency power and and body size.
The specific absorption rate (SAR) describes the potential for heating of the patient's tissue due to the application of the RF energy necessary to produce the MR signal.

See also Specific Absorption Rate, MRI Safety, and MRI Risks.
spacer

• View the DATABASE results for 'Absorbed Dose' (2).Open this link in a new window

 
Further Reading:
  Basics:
Commission delays electromagnetic fields legislation
Monday, 29 October 2007   by cordis.europa.eu:80    
Physics of MRI Safety
   by www.aapm.org    
  News & More:
SED Guidance
Saturday, 1 January 2022   by www.mriphysics.scot.nhs.uk    
Specific Absorption Rate and Specific Energy Dose: Comparison of 1.5-T versus 3.0-T Fetal MRI
Tuesday, 7 April 2020   by pubs.rsna.org    
Evaluation of Absorbed Dose by MRI Read-Out
Saturday, 18 November 2017   by www.jstage.jst.go.jp    
Searchterm 'Energy' was also found in the following services: 
spacer
Radiology  (79) Open this link in a new windowUltrasound  (50) Open this link in a new window
Cross Excitation ArtifactInfoSheet: - Artifacts - 
Case Studies, 
Reduction Index, 
etc.MRI Resource Directory:
 - Artifacts -
 
Energy transfer to nearby slices by the RF pulse.

See Crosstalk Artifact.
spacer
MRI Resources 
RIS - Databases - PACS - Bioinformatics - Contrast Enhanced MRI - Blood Flow Imaging
 
previous      21 - 25 (of 61)     next
Result Pages : [1]  [2 3 4 5 6 7 8 9 10 11 12 13]
 Random Page
 
Share This Page
FacebookTwitterLinkedIn

MR-TIP    
Community   
User
Pass
Forgot your UserID/Password ?    



MRI is trending to low field magnets :
reduced costs will lead to this change 
AI will close the gap to high field 
only in remote areas 
is only temporary 
never 

Look
      Ups





MR-TIP.com uses cookies! By browsing MR-TIP.com, you agree to our use of cookies.

Magnetic Resonance - Technology Information Portal
Member of SoftWays' Medical Imaging Group - MR-TIP • Radiology-TIP • Medical-Ultrasound-Imaging • 
Copyright © 2003 - 2024 SoftWays. All rights reserved. [ 24 April 2024]
Terms of Use | Privacy Policy | Advertising
 [last update: 2024-02-26 03:41:00]