Dotarem®InfoSheet: - Contrast Agents - 
Intro, Overview, 
Characteristics, 
Types of, 
etc.MRI Resource Directory:
 - Contrast Agents -
 
Dotarem® is a paramagnetic ionic MRI contrast agent. Extracellular contrast agents like Dotarem®, can be bolus injected because of the relatively low rate of side effects. This contrast medium is useable to enhance signal intensity in magnetic resonance imaging for intracranial and spinal lesions with an abnormal blood brain barrier or abnormal vascularity, and in whole body imaging.
WARNING: NEPHROGENIC SYSTEMIC FIBROSIS Gadolinium-based contrast agents increase the risk for nephrogenic systemic fibrosis (NSF) in patients with acute or chronic severe renal insufficiency (glomerular filtration rate less than 30 mL/min/1.73m2), or acute renal insufficiency of any severity due to the hepato-renal syndrome or in the perioperative liver transplantation period.

Drug Information and Specification
NAME OF COMPOUND Gadoterate meglumine, Gd-DOTA
DEVELOPER Guerbet S.A.
CENTRAL MOIETY Gd2+
CONTRAST EFFECT T1, Predominantly positive enhancement
RELAXIVITY r1=3.4, r2=4.8, B0=1.0T
PHARMACOKINETIC Intravascular, extracellular, renal excretion
OSMOLALITY 1350 mosm/kgH2O
CONCENTRATION 0.5 mol/L
DOSAGE 0.1 mmol/kg / 0.2mL/kg
PREPARATION Finished product
INDICATION Neuro/whole body
DEVELOPMENT STAGE For sale
DISTRIBUTOR See below
PRESENTATION Vials of 5, 10, 15, 20mL
Pre-filled syringes of 15 and 20 mL
DO NOT RELY ON THE INFORMATION PROVIDED HERE, THEY ARE NOT A SUBSTITUTE FOR THE ACCOMPANYING PACKAGE INSERT!

Distribution Information
TERRITORY TRADE NAME DEVELOPMENT
STAGE
DISTRIBUTOR
EU Dotarem® for sale Guerbet S.A.
France, Switzerland Artirem® for sale Guerbet S.A.
Australia Dotarem® for sale

spacer
 
• Share the entry 'Dotarem®':  Facebook  Twitter  LinkedIn  
 
Further Reading:
  Basics:
Important Drug Warning for Gadolinium-Based Contrast Agents
Wednesday, 12 September 2007   by www.ismrm.org    
  News & More:
Guerbet to Exhibit Recently U.S. Approved Imaging Agents at 100 Year Anniversary of RSNA
Thursday, 13 November 2014   by money.cnn.com    
MRI Resources 
Developers - Patient Information - Health - Education pool - Directories - RIS
 
Artirem®InfoSheet: - Contrast Agents - 
Intro, Overview, 
Characteristics, 
Types of, 
etc.MRI Resource Directory:
 - Contrast Agents -
 
Artirem®, the arthrography-specific contrast agent for MRI is a dilute form of Dotarem® with a less concentration of Gd (1:200). Artirem® has to be injected directly into the joints for better visualization and delimitation, of the ligament and tendon structures in particular.

Drug Information and Specification
NAME OF COMPOUND Gadoterate meglumine, Gd-DOTA
DEVELOPER Guerbet S.A.
CENTRAL MOIETY Gd2+
CONTRAST EFFECT T1, Predominantly positive enhancement
RELAXIVITY r1=3.4, r2=4.8, B0=1.0T
PHARMACOKINETIC Intravascular, extracellular, renal excretion
CONCENTRATION 0,0025 mmol/ml
PREPARATION Finished product
INDICATION Arthrography
DEVELOPMENT STAGE For sale
DISTRIBUTOR See below
PRESENTATION Pre-filled syringes of 20 mL
DO NOT RELY ON THE INFORMATION PROVIDED HERE, THEY ARE NOT A SUBSTITUTE FOR THE ACCOMPANYING PACKAGE INSERT!

Distribution Information
TERRITORY TRADE NAME DEVELOPMENT
STAGE
DISTRIBUTOR
EU Dotarem® for sale Guerbet S.A.
France, Switzerland Artirem® for sale Guerbet S.A.
Australia Dotarem® for sale

spacer

• View the DATABASE results for 'Artirem®' (4).Open this link in a new window

MRI Resources 
MRI Technician and Technologist Schools - Crystallography - MRI Training Courses - Movies - General - Cardiovascular Imaging
 
Guerbet S.A.
 
www.guerbet.com/home_va.html The France-based Guerbet Group is highly specialized in contrast media for medical imaging. Its strategic goal is to be a key player in this market. Products include Dotarem (Magnetic Resonance Imaging) and Xenetix (X-ray Imaging).

Product Information
TRADE NAME
(LOCAL DISTRIBUTION)
FOR SALE FOR SALE /
DEVELOPMENT
DEVELOPMENT
Dotarem®
Endorem™
Lumirem®
Artirem®
Sinerem®
Vistarem™
P717
P760

Contact Information
MAIL Guerbet
Boite postale 50400
95943 Roissy
Charles de Gaulle Cedex
FRANCE
PHONE +33-1-45-91-50-00
FAX +33-1-45-91-51-99
ONLINE www.guerbet.com
spacer

• View the DATABASE results for 'Guerbet S.A.' (7).Open this link in a new window


• View the NEWS results for 'Guerbet S.A.' (2).Open this link in a new window.
 
Further Reading:
  News & More:
ANNUAL REPORT 2001 Guerbet S.A.(.pdf)
2001   by www.guerbet.de    
Searchterm 'Dotarem' was also found in the following service: 
spacer
News  (10)  
 
Extracellular Fluid AgentsInfoSheet: - Contrast Agents - 
Intro, Overview, 
Characteristics, 
Types of, 
etc.MRI Resource Directory:
 - Contrast Agents -
 
The contrast agents are either renal or hepatically excreted media, which stay in the intravascular/extracellular tissue compartment. The enhancement in the blood continues for as long as the contrast agent remains in the blood stream.
E.g. Dotarem®, Magnevist®, Omniscan®, ProHance®.
See Contrast Medium, Contrast Agents and Blood Pool Agents.
spacer

• View the DATABASE results for 'Extracellular Fluid Agents' (2).Open this link in a new window

MRI Resources 
Mass Spectrometry - Shoulder MRI - Musculoskeletal and Joint MRI - Universities - Safety Training - MRI Technician and Technologist Jobs
 
GadoliniumForum -
related threadsInfoSheet: - Contrast Agents - 
Intro, Overview, 
Characteristics, 
Types of, 
etc.
 
(Gd) Gadolinium is a Lanthanide element that is paramagnetic in its trivalent state.
This paramagnetic substance is used for MR imaging because of the effect of strongly decreasing the T1 relaxation times of the tissues to which gadolinium has access. When injected during magnetic resonance imaging, gadolinium will tend to change signal intensities by shortening the T1 time in its surroundings.
The relaxivity of gadolinium is an important measure of its efficacy, which is dependent on the chemical properties of the complex. The gadolinium ion cannot be used in its chloride, sulfate, or acetate forms because of poor tolerance and low solubility in water in the neutral pH range. Although toxic by itself, gadolinium can be given safely in a chelated form such as DTPA, that still retains much of its strong effect on relaxation times (relaxivity).
See also Dotarem®, Gadovist®, MultiHance®, Omniscan®, OptiMARK®, and Contrast Agents, the info sheet gives an overview and more in-dept information about different types of MRI contrast agents.
 
Images, Movies, Sliders:
 Normal Lung Gd Perfusion MRI  Open this link in a new window
      

Courtesy of  Robert R. Edelman

 Breast MRI Images T1 Pre - Post Contrast  Open this link in a new window
 Delayed Myocardial Contrast Enhancement from Infarct  Open this link in a new window
      

Courtesy of  Robert R. Edelman
 
spacer

• View the DATABASE results for 'Gadolinium' (66).Open this link in a new window


• View the NEWS results for 'Gadolinium' (17).Open this link in a new window.
 
Further Reading:
  Basics:
DNA-SEEKING GADOLINIUM COMPLEXES FOR NEUTRON CAPTURE THERAPY (NCT) (.pdf)
A LANTHANIDE LANTHOLOGY(.pdf)
   by www.phy.davidson.edu    
Gadolinium Monazite Lanthanides Johan Gadolin Periodic Table Chemistry
Monday, 22 September 2008   by www.sciences360.com    
  News & More:
Contrast agent linked with brain abnormalities on MRI
Tuesday, 17 December 2013   by www.sciencecodex.com    
FDA Approves First Macrocyclic and Ionic Gadolinium-Contrast Agent for MRI
Friday, 22 March 2013   by www.itnonline.com    
Gadolinium oxide nanoparticles enhance MRI contrast
Thursday, 29 September 2011   by nanotechweb.org    
Contrast Agents: Safety Profile
   by www.clinical-mri.com    
Multimodal Nanoparticles for Quantitative Imaging(.pdf)
Tuesday, 13 December 2011   by alexandria.tue.nl    
Gadolinium-Based Agents Safe for MRI Use
Monday, 18 April 2011   by www.renalandurologynews.com    
MRI Resources 
Jobs - PACS - Safety Training - Universities - Used and Refurbished MRI Equipment - RIS
 
     1 - 5 (of 7)     next
Result Pages : [1]  [2]
 Random Page
 
Share This Page
FacebookTwitterLinkedIn

MR-TIP    
Community   
User
Pass
Forgot your UserID/Password ?  



More money should be spend for :
patient comfort 
safety 
large bore system 
magnet room cameras 
more coils 
me 
other 

Look
      Ups





Magnetic Resonance - Technology Information Portal
Member of SoftWays' Medical Imaging Group - MR-TIP • Radiology-TIP • US-TIP • The-Medical-Market
Copyright © 2003 - 2014 SoftWays. All rights reserved. [ 22 December 2014]
Terms of Use | Privacy Policy | Advertising
 [last update: 2014-12-15 06:23:41]