Magnetic Resonance - Technology Information Portal Welcome to MRI Technology
Info
  Sheets

Out-
      side
 



 
 'Display' 
SEARCH FOR    
 
  2 3 5 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Result : Searchterm 'Display' found in 1 term [] and 79 definitions []
1 - 5 (of 80)     next
Result Pages : [1]  [2 3 4 5 6 7 8 9 10 11 12 13 14 15 16]
Searchterm 'Display' was also found in the following services: 
spacer
News  (18)  Resources  (2)  Forum  (11)  
 
Display Matrix
 
The total number of pixels in the selected matrix, which is described by the product of its phase and frequency axis.
spacer
 
• Share the entry 'Display Matrix':  Facebook  Twitter  LinkedIn  
 
• Related Searches:
    • Digital Imaging and Communications in Medicine
    • Acquisition Matrix
    • Resolution
    • Picture Archiving and Communication System
    • Pixel
MRI Resources 
Shielding - Databases - Collections - Directories - Supplies - Mass Spectrometry
 
Cardiovascular ImagingMRI Resource Directory:
 - Cardiovascular Imaging -
 
Cardiovascular MR imaging includes the complete anatomical display of the heart with CINE imaging of all phases of the heartbeat. Ultrafast techniques make breath hold three-dimensional coverage of the heart in different cardiac axes feasible. Cardiac MRI provides reliable anatomical and functional assessment of the heart and evaluation of myocardial viability and coronary artery disease by a noninvasive diagnostic imaging technique.
Cardiovascular MRI offers potential advantages over radioisotopic techniques because it provides superior spatial resolution, does not use ionizing radiation, has no imaging orientations constraints and contrast resolution better than echocardiography. It also offers direct visualization and characterization of atherosclerotic plaques and diseased vessel walls and surrounding tissues in cardiovascular research.
MRI perfusion approaches measure the alteration of regional myocardial magnetic properties after the intravenous injection of contrast agents and assess the extent of injury after a myocardial infarction and the presence of myocardial viability with a technique based on late enhancement. Extracellular MRI contrast agents, like Gd-DTPA, accumulate only in irreversibly damaged myocardium after a time period of at least 10 minutes.
This type of patients may also have an implanted cardiac stent, bypass or a cardiac pacemaker and special caution should be observed on the MRI safety and the contraindications. While a number of coronary stents have been tested and reported to be MRI compatible, coronary stents must be assessed on an individual basis, with the medical team weighing the risks and benefits of the MRI procedure.

Cardiac MRI overview:
Myocardial perfusion imaging and viability
Calculation of ventricular volume, myocardial mass and wall thickness
Functional parameters
Description of a stenosis or aneurysma
Anatomical display of the heart, vessels and the surrounding tissue

Cardiovascular MRI has become one of the most effective noninvasive imaging techniques for almost all groups of heart and vascular disease.
 
Images, Movies, Sliders:
 Angulation of Cardiac Planes Cine Images of Septal Infarct  Open this link in a new window
      

Courtesy of  Robert R. Edelman

 Left Circumflex Ischemia First-pass Contrast Enhancement  Open this link in a new window
      

Courtesy of  Robert R. Edelman

 Delayed Myocardial Contrast Enhancement from Infarct  Open this link in a new window
 
spacer

• View the DATABASE results for 'Cardiovascular Imaging' (18).Open this link in a new window


• View the NEWS results for 'Cardiovascular Imaging' (6).Open this link in a new window.
 
Further Reading:
  Basics:
Cardiac MRI - Technical Aspects Primer
Wednesday, 7 August 2002
Coronary Artery Disease: Combined Stress MR Imaging Protocol-One-Stop Evaluation of Myocardial Perfusion and Function1
   by radiology.rsnajnls.org    
A Guide To Cardiac Imaging
   by www.simplyphysics.com    
  News & More:
New Imaging Technique Reveals Different Heart Motions by Age, Gender
Thursday, 10 December 2009   by www.sciencedaily.com    
MRI Resources 
Veterinary MRI - Diffusion Weighted Imaging - Safety pool - Movies - Jobs pool - MRI Training Courses
 
CineForum -
related threads
 
A series of rapidly recorded multiple images taken at sequential cycles of time and displayed on a monitor in a dynamic movie display format. This technique can be used to show true range of motion studies of joints and parts of the spine.
 
Images, Movies, Sliders:
 Cardiac Infarct Short Axis Cine bFFE 1  Open this link in a new window
    
 
spacer

• View the DATABASE results for 'Cine' (57).Open this link in a new window


• View the NEWS results for 'Cine' (31).Open this link in a new window.
 
Further Reading:
  News & More:
Study identifies new way to predict prognosis for heart failure patients
Tuesday, 10 December 2013   by medicalxpress.com    
Searchterm 'Display' was also found in the following services: 
spacer
News  (18)  Resources  (2)  Forum  (11)  
 
Corrupted Data (Artifact)InfoSheet: - Artifacts - 
Case Studies, 
Reduction Index, 
etc.MRI Resource Directory:
 - Contrast Agents -
 
Quick Overview
Artifact Information
NAME
Corrupted data
DESCRIPTION
Incorrectly interpretation or display
REASON
Corrupted data
HELP
Save to a new or different media
An artifact on a MR image can appear when data read off an optical disc became corrupted. There two effects can be seen.
Firstly, Bands where the intensity has been incorrectly interpreted or secondly areas, where the horizontal position of the pixels has been incorrectly displayed. It is important to be able to differentiate between artifacts caused during a MRI scan, from those caused by the associated hardware of an imaging system.
mri safety guidance
Image Guidance
Review the hardware and store the images on a new disc.
spacer
 
Further Reading:
  Basics:
MRI Artifact Gallery
   by chickscope.beckman.uiuc.edu    
MRI Resources 
Software - MRI Technician and Technologist Jobs - Breast MRI - MRI Accidents - Research Labs - Used and Refurbished MRI Equipment
 
G-SCANInfoSheet: - Devices -
Intro, 
Types of Magnets, 
Overview, 
etc.MRI Resource Directory:
 - Devices -
 
www.esaote.de/04_kernspin/gscan/gscan.htm From Esaote S.p.A.; Esaote introduced the new G-SCAN at the RSNA in Dec. 2004. The G-SCAN covers almost all musculoskeletal applications including the spine. The tilting gantry is designed for scanning in weight-bearing positions. This unique MRI scanner is developed in line with the Esaote philosophy of creating high quality MRI systems that are easy to install and that have a low breakeven point.
Device Information and Specification
CLINICAL APPLICATION
CONFIGURATION
Spine, extremity, shoulder, flex coil, knee dual phased array, ankle//foot dual phased array, hand//wrist dual phased array
PULSE SEQUENCES
SE, GE, IR, STIR, TSE, 3D CE, GE-STIR, 3D GE, ME, TME, HSE
IMAGING MODES
Single, multislice, volume study, fast scan, multi slab, cine
FOV
100 up to 350 mm, 25 mm displayed
512 x 512
MEASURING MATRIX
256 x 256 maximum
MAGNET TYPE
Permanent
BORE DIAMETER
or W x H
33 cm H, open
POWER REQUIREMENTS
100/110/200/220/230/240 V
STRENGTH
25 mT/m
5-GAUSS FRINGE FIELD
180 cm
Passive
spacer

• View the DATABASE results for 'G-SCAN' (3).Open this link in a new window

MRI Resources 
Equipment - Jobs - General - Mass Spectrometry - Implant and Prosthesis - MR Myelography
 
     1 - 5 (of 80)     next
Result Pages : [1]  [2 3 4 5 6 7 8 9 10 11 12 13 14 15 16]
 Random Page
 
Share This Page
FacebookTwitterLinkedIn

MR-TIP    
Community   
User
Pass
Forgot your UserID/Password ?    



MRI is trending to low field magnets :
reduced costs will lead to this change 
AI will close the gap to high field 
only in remote areas 
is only temporary 
never 

Look
      Ups





MR-TIP.com uses cookies! By browsing MR-TIP.com, you agree to our use of cookies.

Magnetic Resonance - Technology Information Portal
Member of SoftWays' Medical Imaging Group - MR-TIP • Radiology-TIP • Medical-Ultrasound-Imaging • 
Copyright © 2003 - 2024 SoftWays. All rights reserved. [ 24 April 2024]
Terms of Use | Privacy Policy | Advertising
 [last update: 2024-02-26 03:41:00]