C-SCAN™InfoSheet: - Devices -
Intro, 
Types of Magnets, 
Overview, 
etc.MRI Resource Directory:
 - Devices -
 
www.gehealthcare.com/usen/mr/cscan/index.html

Manufactured by Esaote S.p.A.; compact in-office MRI system, fits in a 90 ft² (8.4 m²) space and requires no shielding or special power. This low field MRI magnet is optimized for orthopedic use and imaging of the extremities.
The C-SCAN™ is developed from the ARTOSCAN™ - M with a new computer platform, and is also known as Artoscan C.
Esaote North America and Hologic Inc. are the U.S. distributors of this MRI device.


Device Information and Specification
CLINICAL APPLICATION Dedicated extremity
CONFIGURATION Closed
SURFACE COILS Linear and dual phased array, knee, ankle, wrist (6 total) coils
PULSE SEQUENCES SE, GE, IR, STIR, FSE, 3D CE, GE-STIR, 3D GE, ME, TME, HSE
IMAGING MODES Single, multislice, volume study, fast scan, multi slab
TR 12 - 5,000 msec
TE 5 - 220 msec
SINGLE SLICE 0.8 sec/image
MULTISLICE 0.8 sec/image
FOV 10 - 20 cm
SLICE THICKNESS 2D: 2 mm - 10 mm;
3D: 0.6 mm - 10 mm
DISPLAY MATRIX 512 x 512
MEASURING MATRIX 256 x 256 maximum
PIXEL INTENSITY 4,096 gray lvls, 256 lvls in 3D
SPATIAL RESOLUTION 0.4 mm
MAGNET TYPE Permanent
BORE DIAMETER
or W x H
33.6 x 16 cm
MAGNET WEIGHT 960 kg
H*W*D 124 x 76 x 60 cm
POWER REQUIREMENTS 100/110/200/220/230/240
FIELD STRENGTH 0.2 T
STRENGTH 10 mT/m
5-GAUSS FRINGE FIELD, radial/axial 28 cm/60 cm
SHIMMING Passive

spacer
MRI Resources 
Shielding - Pregnancy - Online Books - Coils - RIS - Abdominal Imaging
 
CHORUS 1.5T™InfoSheet: - Devices -
Intro, 
Types of Magnets, 
Overview, 
etc.MRI Resource Directory:
 - Devices -
 
www.isoltech.co.kr/english/product/default.htm

From ISOL Technology
'Next generation MRI system 1.5T CHORUS developed by ISOL Technology is optimized for both clinical diagnostic imaging and for research development.
CHORUS offers the complete range of feature oriented advanced imaging techniques- for both clinical routine and research. The compact short bore magnet, the patient friendly design and the gradient technology make the innovation to new degree of perfection in magnetic resonance.'


Device Information and Specification
CLINICAL APPLICATION Whole body
CONFIGURATION Short bore
SURFACE COILS Head, C-spine, L-spine, TMJ, Knee, Shoulder, General purpose, Phased Array System: 4 digital receiver channels (Up to 12 channels)
SPECTROSCOPY Optional
SYNCHRONIZATION ECG/peripheral: Optional/yes, respiratory gating
PULSE SEQUENCES Spin Echo, Gradient Echo, Fast Spin Echo, Inversion Recovery (STIR, Fluid Attenuated Inversion Recovery), FLASH, FISP, PSIF, Turbo Flash ( MPRAGE ),TOF MR Angiography, Standard echo planar imaging package (SE-EPI, GE-EPI), Optional: Advanced P.A. Imaging Package (up to 4 ch.), Advanced echo planar imaging package, Single Shot and Diffusion Weighted EPI, IR/FLAIR EPI
IMAGING MODES 2D/3D, Travelling Sat, Multi-Slab 3D, MTC and TONE Pulse Sequence, Fat/Water Suppression, Presaturation (up to 6 bands), Flow Compensation using GMR pulse, Multi-Slice, Multi-Group Imaging
SINGLE/MULTI SLICE Image reconstruction time (2562 ) : 0.02 s
FOV 40 cm
MAGNET TYPE Superconducting
BORE DIAMETER
or W x H
58 cm diameter (patient)
MAGNET WEIGHT 4050 kg
H*W*D 233 x 206 x 160 cm
COOLING SYSTEM TYPE Water-cooled coil and air-cooled amplifier
CRYOGEN USE 0.07 L/hr helium
FIELD STRENGTH 1.5 T
STRENGTH 20 mT/m (Upto 27 mT/m)
5-GAUSS FRINGE FIELD 2.5 m / 3.8 m
SHIMMING Passive and active


spacer

• View the DATABASE results for 'CHORUS 1.5T™' (2).Open this link in a new window

MRI Resources 
Societies - Stimulator pool - Spectroscopy - Corporations - Lung Imaging - MRA
 
ENCORE 0.5T™InfoSheet: - Devices -
Intro, 
Types of Magnets, 
Overview, 
etc.MRI Resource Directory:
 - Devices -
 
www.isoltech.co.kr/english/product/05t.htm

From ISOL Technology
'MRI system is not an expensive equipment anymore. ENCORE developed by ISOL Technology is a low cost MRI system with the advantages like of the 1.0T MRI scanner. Developed specially for the overseas market, the ENCORE is gaining popularity in the domestic market by medium sized hospitals.
Due to the optimum RF and Gradient application technology. ENCORE enables to obtain high resolution imaging and 2D/3D Angio images which was only possible in high field MR systems.'
- Less consumption of the helium gas due to the ultra-lightweight magnet specially designed and manufactured for ISOL. - Cost efficiency MR system due to air cooling type (equivalent to permanent magnetic). - Patient processing speed of less than 20 minutes



Device Information and Specification
CLINICAL APPLICATION Whole body
CONFIGURATION Short bore compact
SURFACE COILS Head, C-spine, L-spine, TMJ, Knee, Shoulder, General purpose, Phased Array System: 4 digital receiver channels (Up to 12 channels)
SYNCHRONIZATION ECG/peripheral: Optional/yes, respiratory gating
PULSE SEQUENCES Spin Echo, Gradient Echo, Fast Spin Echo, Inversion Recovery (STIR, FLAIR), FLASH, FISP, PSIF, Turbo Flash ( MPRAGE ),TOF MR Angiography
IMAGING MODES 2D/3D, Travelling Sat, Multi-Slab 3D, MTC and TONE Pulse Sequence, Fat/Water Suppression, Presaturation (up to 6 bands), Flow Compensation using GMR pulse, Multi-Slice, Multi-Group Imaging
SINGLE/MULTI SLICE Image reconstruction time (2562 ) : 0.02 s
FOV 40 cm
MAGNET TYPE Superconducting
BORE DIAMETER
or W x H
58 cm diameter
MAGNET WEIGHT 3200 kg
H*W*D 200 x 168 x 187 cm
COOLING SYSTEM TYPE Air-cooled coil and amplifier
CRYOGEN USE 0.05 L/hr helium
FIELD STRENGTH 0.5 T
STRENGTH 15 mT/m
5-GAUSS FRINGE FIELD 2.3 m / 3.1 m
SHIMMING Passive and active

spacer

• View the DATABASE results for 'ENCORE 0.5T™' (2).Open this link in a new window

Searchterm 'Device Information' was also found in the following services: 
spacer
News  (2)  Resources  (4)  
 
Echelon™ 1.5TInfoSheet: - Devices -
Intro, 
Types of Magnets, 
Overview, 
etc.
 
www.hitachimed.com/contentindex.asp?ID=971

From Hitachi Medical Systems America Inc.;
Hitachi expanded its portfolio with the Echelon™ 1.5T. The MRI scanner combines a compact magnet and a scalable 8-channel RF system with high-performance gradients and slew rate to select short echo times, small field of views, high matrices and thin slices. Standard features of the Echelon MRI system include higher-order active shim, RAPID (parallel imaging for use on brain MRI, body, cardiovascular imaging, and orthopedic coils), multiple coil ports, and an advanced reconstruction engine.


Device Information and Specification
CLINICAL APPLICATION Whole body
CONFIGURATION Short bore
SURFACE COILS Head, body coil, spine, breast, knee, shoulder, vascular multiple array coils.
SYNCHRONIZATION Cardiac gating, ECG/peripheral, respiratory gating
PULSE SEQUENCES SE, IR, FSE, FIR, GE, SG, BASG, PBSG, PCIR, DWI, Radial, Angiography: TOF, FLUTE (Fluoro-triggered bolus MRA), Time-resolved MRA
IMAGING MODES Single, multislice, volume study
PIXEL INTENSITY Level Range: -2,000 to +4,000
SPATIAL RESOLUTION Sub millimeter
MAGNET TYPE Superconducting
POWER REQUIREMENTS 208/220/240 V, single phase
CRYOGEN USE Low cryogen boil-off
FIELD STRENGTH 1.5 T
STRENGTH 30 mT/m
SLEW RATE 150 T/m/sec
SHIMMING Higher-order active shim


spacer

• View the DATABASE results for 'Echelon™ 1.5T' (2).Open this link in a new window


• View the NEWS results for 'Echelon™ 1.5T' (3).Open this link in a new window.
 
Further Reading:
  Basics:
Echelon 1.5T
   by www.hitachimed.com    
MRI Resources 
Case Studies - Directories - General - MRI Physics - Process Analysis - Anatomy
 
Excelart AG™ with PianissimoInfoSheet: - Devices -
Intro, 
Types of Magnets, 
Overview, 
etc.MRI Resource Directory:
 - Devices -
 
From Toshiba America Medical Systems Inc.;
http://www.medical.toshiba.com/clinical/radiology/15texcelart.htm

the EXCELART is a superconducting whole body MRI system with a short wide-bore magnet, operating at 1.5 T. It features powerful high-speed gradients with a revolutionary gradient acoustic noise reduction system: Pianissimo. The dramatic reduction of gradient acoustic noise by Pianissimo greatly enhances patient comfort during exams. The standard array platform and a wide range of array coils ensure excellent images. A powerful 64-bit RISC-based computer system and newly developed array processor realize high productivity.


Device Information and Specification
CLINICAL APPLICATION Whole body
CONFIGURATION Cylindrical Wide Short Bore
SURFACE COILS Body, head, spine, knee, neck, TMJ, extremity, breast, shoulder
SPECTROSCOPY Opt. (WIP) Single and Multi Voxel
SYNCHRONIZATION ECG: standard; peripheral: optional, respiratory gating
PULSE SEQUENCES SE, FE, IR, FastSE, FastIR, FastFLAIR, Fast STIR, FastFE, FASE, Hybrid EPI, Multi Shot EPI; Angiography: 2D(gate/non-gate)/3D TOF, SORS-STC
IMAGING MODES Single, multislice, volume study
TR 3.5-30000 msec
TE 8 msec min. SE; 1.2 msec min. FE
SINGLE/MULTI SLICE less than 0.015 (256x256)
FOV 2 cm
SLICE THICKNESS 1.0 min. 2-DFT: 0.2 min. 3-DFT
DISPLAY MATRIX Up to 1024
MEASURING MATRIX 32-1024, phase;; 64-1024, freq.
PIXEL INTENSITY 256 gray levels
SPATIAL RESOLUTION 0.16 mm
MAGNET TYPE Superconducting
BORE DIAMETER
or W x H
65.5 cm, patient aperture
MAGNET WEIGHT 4050 kg (bare magnet incl. L-He)
H*W*D 235 x 219 x 199 cm
POWER REQUIREMENTS 380/400/415/440/480 V
COOLING SYSTEM TYPE Closed-loop water-cooled
CRYOGEN USE Liquid helium: approx. less than 0.05 L/hr
FIELD STRENGTH 1.5 T
STRENGTH 25 mT/m
5-GAUSS FRINGE FIELD 2.5 m / 4.0 m
SHIMMING Passive, active, auto-active


spacer

• View the DATABASE results for 'Excelart AG™ with Pianissimo' (2).Open this link in a new window

MRI Resources 
Raman Spectroscopy - MRA - Cochlear Implant - Absorption and Emission - Chemistry - Patient Information
 
previous      6 - 10 (of 70)     next
Result Pages : [1 2 3 4 5 6 7 8 9 10 11 12 13 14]
 Random Page
 
Share This Page
FacebookTwitterLinkedIn

MR-TIP    
Community   
User
Pass
Forgot your UserID/Password ?  



Your MRI scanner(s) in 5 years should be :
more automated 
much quicker 
quiet 
voice controlled 
iPhone compatible 
as it is right now 

Look
      Ups





MR-TIP.com uses cookies! By browsing MR-TIP.com, you agree to our use of cookies.

Magnetic Resonance - Technology Information Portal
Member of SoftWays' Medical Imaging Group - MR-TIP • Radiology-TIP • US-TIP • The-Medical-Market
Copyright © 2003 - 2016 SoftWays. All rights reserved. [ 28 June 2017]
Terms of Use | Privacy Policy | Advertising
 [last update: 2017-06-21 05:49:00]