Magnetic Resonance - Technology Information Portal Welcome to MRI Technology••
Info
  Sheets


Out-
      side
 



 
 'Device Information' 
SEARCH FOR    
 
  2 3 5 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Result : Searchterm 'Device Information' found in 0 term [] and 70 definitions []
previous     66 - 70 (of 70)     
Result Pages : [1 2 3 4 5 6 7 8 9 10 11 12 13 14]
Searchterm 'Device Information' was also found in the following services: 
spacer
News  (2)  Resources  (4)  
 
Upright™ MRIInfoSheet: - Devices -
Intro, 
Types of Magnets, 
Overview, 
etc.MRI Resource Directory:
 - Devices -
 
www.fonar.com/standup.htm www.fonar.com/standup.htm www.fonar.com/standup.htm From FONAR Corporation;
in October of 2004, the company changed the product name of the Stand-Up™ MRI to the Upright™ MRI. The Indomitable™, Upright™ MRI is the only open MRI in the world that can perform positional MRI (pMRI), i.e. the Upright MRI™ scans patients in upright, weight-bearing positions, in addition to the conventional lie-down positions. The Upright™ MRI is the only device that can scan patients in the position their symptoms occur, in their position of pain. In early clinical reports independently confirm the effectiveness and potential of positional MRI. In October 2000, Fonar received permission to market the Indomitable™ from the FDA.

Device Information and Specification
CLINICAL APPLICATION Whole body - weight-bearing MRI - position imaging (flexion, extension, bending, standing, sitting and recumbent scanning)
CONFIGURATION Front-open and Top-open MRI
SURFACE COILS Solenoid ("Wrap-around") and planar RF receiver coils
SINGLE/MULTI SLICE 0.1 sec per slice
MULTISLICE 0.1 sec per slice
FOV Min. 6.0 cm
SLICE THICKNESS Min. 0.8 mm (3DFT)
DISPLAY MATRIX 256, 512
MEASURING MATRIX 128 - 512
SPATIAL RESOLUTION 0.5 mm
MAGNET TYPE Iron-frame electromagnet
BORE DIAMETER
or W x H
45.72 cm horizontal
POWER REQUIREMENTS 380/400/415/440/480 V
COOLING SYSTEM TYPE Water, closed-loop
CRYOGEN USE, L/hr -
FIELD STRENGTH 0.6 T
STRENGTH 12 mT/m
5 GAUSS FRINGE FIELD, radial/axial
SHIMMING active, passive
spacer

• View the NEWS results for 'Upright™ MRI' (9).Open this link in a new window.
 
Further Reading:
  Basics:
Product Information - Fonar Corporation
  News & More:
Landmark Independent Study by UCLA School of Medicine Reports Comparison of Dynamic™ Upright® MRI With Static Upright MRI in More Than 1,000 Patients (1,302):
Thursday, 15 November 2007   by www.fonar.com    
FONAR Wins The Wall Street Journal Technology Innovation Award For 2007 For the FONAR UPRIGHT™ Multi-Position™ MRI
Monday, 1 October 2007   by www.fonar.com    
MRI Resources 
IR - Fluorescence - Developers - Brain MRI - - MRI Technician and Technologist Jobs
 
VISART™InfoSheet: - Devices -
Intro, 
Types of Magnets, 
Overview, 
etc.MRI Resource Directory:
 - Devices -
 
From Toshiba America Medical Systems Inc.;
http://www.medical.toshiba.com/clinical/radiology/15texcelart.htm VISART™ series is a 1.5 Tesla superconducting MRI system that has been designed to meet the expanding role of MRI in today's clinical environment. The system utilizes innovative technologies such as digital RF, high speed actively shielded gradients and optimized RF coils, which support a wide range of MRI developments. The Visart, an early type of Toshiba Medical Systems Inc., can be retrofitted or upgraded to the Excelart configuration.
Device Information and Specification
CLINICAL APPLICATION Whole body
CONFIGURATION Compact
SURFACE COILS Quadrature, solenoid and multi-channel configurations
SYNCHRONIZATION ECG/peripheral optional, respiratory gating
PULSE SEQUENCES SE, FE, IR, FastSE, FastIR, FastFLAIR, Fast STIR, FastFE, FASE, Hybrid EPI, Multi Shot EPI; Angiography: 2D(gate/non-gate)/3D TOF, SORS-STC
IMAGING MODES Single, multislice, volume study
MAGNET TYPE Superconducting
POWER REQUIREMENTS 380/400/415/440/480 V
COOLING SYSTEM TYPE Closed-loop water-cooled
FIELD STRENGTH 1.5 T
STRENGTH 25 mT/m
SHIMMING Passive, active
spacer

• View the DATABASE results for 'VISART™' (2).Open this link in a new window

 
Further Reading:
  News & More:
Angio, cardiac imaging top list for MR and CT
1999   by www.diagnosticimaging.com    
MRI Resources 
Universities - Mobile MRI - Devices - Movies - Cardiovascular Imaging - Pediatric and Fetal MRI
 
Vantage™InfoSheet: - Devices -
Intro, 
Types of Magnets, 
Overview, 
etc.MRI Resource Directory:
 - Devices -
 
From Toshiba America Medical Systems Inc.;
http://www.medical.toshiba.com/clinical/radiology/vantage.htm 'With its high-field strength, the Vantage™ delivers the clinical capabilities and image quality expected by cardiologists, while simultaneously offering patients a more comfortable and non-invasive option,' said Dane Peshe, director, MRI Business Unit, Toshiba America Medical Systems. 'Vantage™ supports a full complement of cardiovascular imaging studies, ranging from stroke evaluation to peripheral vascular imaging. Additionally, the ultra short bore design offers patients a greater feeling of openness that reduces claustrophobic sensations, while Toshiba's exclusive, patented Pianissimo™ technology reduces scan noise by as much as 90 percent for a more pleasant experience.'

Device Information and Specification
CLINICAL APPLICATION Whole body
CONFIGURATION Ultra short bore
SURFACE COILS Body, head, cardiac, spine, knee, neck, TMJ, extremity, breast, shoulder
SYNCHRONIZATION ECG/peripheral, respiratory gating
PULSE SEQUENCES SE, FE, IR, FastSE, FastIR, FastFLAIR, Fast STIR, FastFE, FASE, EPI, SuperFASE; Angiography: 2D(gate/non-gate)/3D TOF, SORS-STC
IMAGING MODES Single, multislice, volume study
FOV 50 cm
DISPLAY MATRIX Up to 1024
MEASURING MATRIX 32-1024, phase;; 64-1024, freq.
PIXEL INTENSITY 256 gray levels
MAGNET TYPE Superconducting
BORE DIAMETER
or W x H
65.5 cm
H*W*D ? x ? x 149.5 cm
POWER REQUIREMENTS 380/400/415/440/480 V
COOLING SYSTEM TYPE Closed-loop water-cooled
CRYOGEN USE Liquid helium: approx. less than 0.05 L/hr
FIELD STRENGTH 1.5 T
STRENGTH 30 mT/m
SHIMMING Passive, active, auto-active
spacer

• View the DATABASE results for 'Vantage™' (2).Open this link in a new window

 
Further Reading:
  Basics:
Toshiba Receives FDA Clearance for Vantage Titan MR System
Monday, 28 January 2008   by www.businesswire.com    
Searchterm 'Device Information' was also found in the following services: 
spacer
News  (2)  Resources  (4)  
 
Virgo™InfoSheet: - Devices -
Intro, 
Types of Magnets, 
Overview, 
etc.MRI Resource Directory:
 - Devices -
 
From Virgo
www.canamglobal.com/mri/virgomri.html This open C-shaped MRI system eases patient comfort and technologist maneuverability. The Virgo™ patient table is detachable and moves on easy rolling castors. Able to accommodate patient weights up to 160 kg, the tabletop has a range of motion of 30 cm in the lateral direction and 90cm in the longitudinal direction.
(Sorry, no picture available.)

Device Information and Specification
CLINICAL APPLICATION Whole body
CONFIGURATION C shaped
SURFACE COILS Head, Body, Neck, Knee, Shoulder, Spine, Wrist, Breast, Extremity, Lumbar Spine, TMJ
SPECTROSCOPY No
SYNCHRONIZATION Standard cardiac gating, ECG/peripheral, respiratory gating
PULSE SEQUENCES 2D Spin Echo (single and multi-echo), 2D Inversion Recovery, 2D Sequential and 3D Volume Gradient Echo, 2D and 3D Spoiled Gradient Echo
IMAGING MODES Localizer, single slice, multislice, volume, fast, POMP, multi slab, cine, slice and frequency zip, extended dynamic range, tailored RF
TR steps of 1 msec
TE steps of 1 msec
SINGLE/MULTI SLICE Simultaneous scan and reconstruction;; 100 images/second reconstruction
FOV 400 mm
SLICE THICKNESS 2D : 2 mm; 3D : 0.5 mm
MEASURING MATRIX 512x512
PIXEL INTENSITY 256 gray levels
MAGNET TYPE Permanent
BORE DIAMETER
or Vertical Gap
44 cm
FIELD STRENGTH 0.35 T
STRENGTH 15 mT/m
5-GAUSS FRINGE FIELD 3 m/3 m
SHIMMING Passive
spacer
MRI Resources 
Fluorescence - Devices - Databases - MRI Technician and Technologist Schools - Shoulder MRI - RIS
 
iMotion™ 1.5 Tesla MagnetInfoSheet: - Devices -
Intro, 
Types of Magnets, 
Overview, 
etc.MRI Resource Directory:
 - Devices -
 
www.imris.com/ The mobile intraoperative iMotion system produces real-time images used for MR guided surgery and offers functional magnetic resonance imaging, MR spectroscopy, perfusion imaging, and diffusion weighted imaging capabilities.
The iMotion 1.5 T magnet moves to the patient, gliding in and out of place as needed, without affecting surgical, anesthetic, and nursing management.
See also Intraoperative Magnetic Resonance Imaging, MR Guided Interventions.
Device Information and Specification
CLINICAL APPLICATION Whole body
CONFIGURATION Mobile compact
SURFACE COILS Whole body, intra-operative head, neck volume, atlas head//neck vascular quadrature phased array, spine quadrature, C/T/L spine phased array, small joint, large joint, TMJ bilateral, shoulder phased array, extremity quadrature volume, wrist, hand quadrature, general purpose flexible, pelvis/abdomen phased array, body quadrature, phased array flexible, breast bilateral
SPECTROSCOPY SVS, CSI
SYNCHRONIZATION Standard cardiac gating, ECG/peripheral, respiratory gating
PULSE SEQUENCES SE, IR, TSE, EPI, Diffusion, Perfusion, Angiography
IMAGING MODES Localizer, single slice, multislice, volume
MAGNET TYPE Superconducting
FIELD STRENGTH 1.5 T
SHIMMING Active
spacer

• View the DATABASE results for 'iMotion™ 1.5 Tesla Magnet' (2).Open this link in a new window

 
Further Reading:
  News & More:
Siemens and IMRIS Partner to Offer Ceiling-Mounted MRI; Movable iMotion System Serves Both Operating Rooms and Diagnostic Imaging Departments, Enables Significantly Improved Return on Investment.
Tuesday, 4 April 2006   by www.thefreelibrary.com    
IMRIS receives FDA clearance for next generation VISIUS Surgical Theatre
Thursday, 13 February 2014   by www.imris.com    
MRI Resources 
Non-English - Most Wanted - Hospitals - Used and Refurbished MRI Equipment - Research Labs - Manufacturers
 
previous      66 - 70 (of 70)     
Result Pages : [1 2 3 4 5 6 7 8 9 10 11 12 13 14]
 Random Page
 
Share This Page
FacebookTwitterLinkedIn

MR-TIP    
Community   
User
Pass
Forgot your UserID/Password ?  



In 2020 your scanner will probably work with a field strength of :
lower 
1T 
1.5T 
2T 
3T 
7T 
higher 

Look
      Ups





MR-TIP.com uses cookies! By browsing MR-TIP.com, you agree to our use of cookies.

Magnetic Resonance - Technology Information Portal
Member of SoftWays' Medical Imaging Group - MR-TIP • Radiology-TIP • US-TIP • The-Medical-Market
Copyright © 2003 - 2016 SoftWays. All rights reserved. [ 22 May 2017]
Terms of Use | Privacy Policy | Advertising