Magnetic Resonance - Technology Information Portal Welcome to MRI Technology
Info
  Sheets


Out-
      side
 



 
 'Device Information' 
SEARCH FOR    
 
  2 3 5 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Result : Searchterm 'Device Information' found in 0 term [] and 70 definitions []
previous     46 - 50 (of 70)     next
Result Pages : [1 2 3 4 5 6 7 8 9 10 11 12 13 14]
Searchterm 'Device Information' was also found in the following services: 
spacer
News  (2)  Resources  (4)  
 
Opera (E-SCAN™ XQ)InfoSheet: - Devices -
Intro, 
Types of Magnets, 
Overview, 
etc.MRI Resource Directory:
 - Devices -
 
www.esaote.com/products/MRI/eScanXQ/products1.htm

Manufactured by Esaote S.p.A.; a low field open MRI scanner with permanent magnet for orthopedic use. The outstanding feature of this MRI system is a patient friendly design with 24 cm diameter, which allows the imaging of extremities and small body parts like shoulder MRI. The power consumption is around 1.3 kW and the needed minimum floor space is an area of 16 sq m.
At RSNA 2006 Hologic Inc. introduced a new dedicated extremity MRI scanner, the Opera. Manufactured by Esaote is the Opera a redesign of Esaote’s 0.2 Tesla E-Scan XQ platform, which now enables complete imaging of all extremities, including hip and shoulder applications. 'Real-time positioning' reportedly speeds patient setup and reduces exam times.
Esaote North America and Hologic Inc are the U.S. distributors of this MRI device.


Device Information and Specification
CLINICAL APPLICATION Dedicated extremity
CONFIGURATION Open MRI
SURFACE COILS Extremity, shoulder (2), flex coil, knee dual phased array, ankle//foot dual phased array, hand//wrist dual phased array coil
PULSE SEQUENCES SE, GE, IR, STIR, FSE, 3D CE, GE-STIR, 3D GE, ME, TME, HSE
IMAGING MODES Single, multislice, volume study, fast scan, multi slab
TR 10 - 5000 msec
TE 6 - 110 msec
SINGLE SLICE 0.6 sec/image
MULTISLICE 0.6 sec/image
FOV 17 cm
SLICE THICKNESS 2D: 2 mm - 10 mm;
3D: 0.6 mm - 10 mm
DISPLAY MATRIX 512 x 512
MEASURING MATRIX 256 x 256 maximum
PIXEL INTENSITY 4096 gray lvls, 256 lvls in 3D
SPATIAL RESOLUTION 0.4 mm
MAGNET TYPE Permanent
BORE DIAMETER
or W x H
24 cm H, open
MAGNET WEIGHT 2250 kg, 4960 lbs
H*W*D 79 x 65 x 85 cm
POWER REQUIREMENTS 2,0 kW; 110/220 V single phase
FIELD STRENGTH 0.2 T
STRENGTH 20 mT/m
5-GAUSS FRINGE FIELD, radial/axial 150 cm/130 cm
SHIMMING Passive

spacer
 
Further Reading:
  News & More:
E-Scan, 510(k) Summary(.pdf)
Saturday, 15 May 2004   by www.accessdata.fda.gov    
MRI Resources 
Image Quality - Stimulator pool - Knee MRI - MR Myelography - Fluorescence - MR Guided Interventions
 
Panorama 0.23T™InfoSheet: - Devices -
Intro, 
Types of Magnets, 
Overview, 
etc.MRI Resource Directory:
 - Devices -
 
From Philips Medical Systems;
www.medical.philips.com/main/products/mri/products/panoramafamily/panorama0.23t_rt/features/ the Panorama 0.23 T, providing a new design optimized for patient comfort, faster reconstruction time than before (300 images/second) and new gradient specifications. Philips' Panorama 0.23 T I/T supports MR-guided interventions, resulting in minimally invasive procedures, more targeted surgery, reduced recovery time and shorter hospital stays. Optional OptoGuide functionality enables real-time needle tracking. Philips' Panorama 0.23 T™ R/T is the first and only open MRI system to enable radiation therapy planning using MR data sets. The Panorama also features the new and consistent Philips User Interface, an essential element of the Vequion clinical IT family of products and services.

Device Information and Specification
CLINICAL APPLICATION Whole body
CONFIGURATION Open MRI/C-arm
SURFACE COILS Head, head-neck, extremity M-L, neck, body/spine S-XL, shoulder, bilateral breast, wrist, TMJ, flex XS-S-M-L-XL-XXL
SPECTROSCOPY No
SYNCHRONIZATION ECG/peripheral: Optional/optional, respiratory gating
PULSE SEQUENCES SE, FE, IR, FFE, DEFFE, DESE, TSE, DETSE, Single shot SE, DRIVE, Balanced FFE, MRCP, Fluid Attenuated Inversion Recovery, Turbo FLAIR, IR-TSE, T1-STIR TSE, T2-STIR TSE, Diffusion Imaging, 3D SE, 3D FFE, MTC;; Angiography: CE-ANGIO, MRA 2D, 3D TOF
IMAGING MODES Single, multislice, volume study, dynamic, SIMEX, multi chunk 3D, multiple stacks
TR Min. 6.2 msec
TE Min. 2.8 msec
SINGLE/MULTI SLICE 50 slices/sec
FOV 0.4 cm - 40 cm
SLICE THICKNESS 0.4 mm
DISPLAY MATRIX 1280 X 1024
MEASURING MATRIX Up to 512 x 512
PIXEL INTENSITY 256 gray scale
SPATIAL RESOLUTION 0.78 mm
MAGNET TYPE Resistive/iron core
BORE DIAMETER
or W x H
Open x 46 cm x infinite (side-first patient entry)
MAGNET WEIGHT 13110 kg
H*W*D 196 x 121 x 176 cm
POWER REQUIREMENTS 400/480 V
COOLING SYSTEM TYPE Closed loop chilled water (chiller included)
CRYOGEN USE N/A
FIELD STRENGTH 0.23 T
STRENGTH 19 mT/m
5-GAUSS FRINGE FIELD 2.4 m / 3.7 m
SHIMMING Passive/active
spacer

• View the DATABASE results for 'Panorama 0.23T™' (2).Open this link in a new window

 
Further Reading:
  News & More:
Magnetic resonance imaging guided musculoskeletal interventions at 0.23T: Chapter 4. Materials and methods
2002
MRI Resources 
Breast Implant - Cardiovascular Imaging - Examinations - Stent - Services and Supplies - Resources
 
Panorama 0.6T™InfoSheet: - Devices -
Intro, 
Types of Magnets, 
Overview, 
etc.MRI Resource Directory:
 - Devices -
 
From Philips Medical Systems;
www.medical.philips.com/main/products/mri/products/panoramafamily/panorama0.23t_rt/features/ Panorama 0.6 T is the Philips Mid-Field Open MRI system. It is the most open MR scanner in the market, optimized for patient comfort and faster reconstruction time.

Device Information and Specification
CLINICAL APPLICATION Whole body
CONFIGURATION Open MRI/C-arm
SURFACE COILS Head, head-neck, extremity, neck, body/spine M-XL, shoulder, bilateral breast, wrist, TMJ, flex XS-S-M-L-XL-XXL
SPECTROSCOPY No
SYNCHRONIZATION ECG/peripheral: Optional/yes, respiratory gating
PULSE SEQUENCES SE, FE, IR, STIR, FFE, DEFFE, DESE, TSE, DETSE, Single shot SE, DRIVE, Balanced FFE, MRCP, Fluid Attenuated Inversion Recovery, Turbo FLAIR, IR-TSE, T1-STIR TSE, T2-STIR TSE, Diffusion Imaging, 3D SE, 3D FFE, Contrast Perfusion Analysis, MTC;; Angiography: CE-ANGIO, MRA 2D, 3D TOF
IMAGING MODES Single, multislice, volume study, dynamic, SIMEX, multi chunk 3D, multiple stacks
TR Min. 4.6 msec
TE Min. 2.3 msec
SINGLE/MULTI SLICE 50 slices/sec
FOV 0.4 cm - 42 cm
SLICE THICKNESS 0.4 mm
DISPLAY MATRIX 1280 X 1024
MEASURING MATRIX Up to 512 x 512
PIXEL INTENSITY 256 gray scale
SPATIAL RESOLUTION 0.78 mm
MAGNET TYPE Superconducting / iron core
BORE DIAMETER
or W x H
Open x 47 cm x infinite (side-first patient entry)
MAGNET WEIGHT 38000 kg
H*W*D 254 x 244 x 325 cm
POWER REQUIREMENTS 400/480 V
COOLING SYSTEM TYPE Liquid helium//air cool
CRYOGEN USE 0.00 L/hr helium
FIELD STRENGTH 0.6 T
STRENGTH 20 mT/m
5-GAUSS FRINGE FIELD 2.4 m / 2.5 m
SHIMMING Passive/active
spacer

• View the DATABASE results for 'Panorama 0.6T™' (2).Open this link in a new window

Searchterm 'Device Information' was also found in the following services: 
spacer
News  (2)  Resources  (4)  
 
Panorama 1.0T™InfoSheet: - Devices -
Intro, 
Types of Magnets, 
Overview, 
etc.MRI Resource Directory:
 - Devices -
 
From Philips Medical Systems;
www.medical.philips.com/main/products/mri/products/panoramafamily/panorama1.0t_rt/features/ this active shielded member of the Panorama product line combines the advantages of one 1.0 T system's with the possibilities of an open MRI system. The open design helps ease anxiety for claustrophobic patients and increased patient comfort whereby the field strength provides spectacular image quality and fast patient throughput.
Device Information and Specification
CLINICAL APPLICATION Whole body
CONFIGURATION Vertical Field open MRI post design
SURFACE COILS Vertically opposed solenoids, head, head-neck, extremity, neck, body/spine M-XL, shoulder, bilateral breast, wrist, TMJ, flex XS-S-M-L-XL-XXL
SPECTROSCOPY No
SYNCHRONIZATION ECG/peripheral: Optional/yes, respiratory gating
PULSE SEQUENCES SE, FE, IR, STIR, FFE, DEFFE, DESE, TSE, DETSE, Single shot SE, DRIVE, Balanced FFE, MRCP, FLAIR, Turbo FLAIR, IR-TSE, T1-STIR TSE, T2-STIR TSE, Diffusion Imaging, 3D SE, 3D FFE, Contrast Perfusion Analysis, MTC;; Angiography: CE-ANGIO, MRA 2D, 3D TOF
IMAGING MODES Single, multislice, volume study, dynamic, SIMEX, multi chunk 3D, multiple stacks
TR Min. 4.6 msec
TE Min. 2.3 msec
SINGLE/MULTI SLICE 50 slices/sec
FOV 0.4 cm - 42 cm
SLICE THICKNESS 0.4 mm
DISPLAY MATRIX 1280 X 1024
MEASURING MATRIX Up to 512 x 512
PIXEL INTENSITY 256 gray scale
SPATIAL RESOLUTION 0.78 mm
MAGNET TYPE Superconducting
BORE DIAMETER
or W x H
Open x 47 cm x infinite (side-first patient entry)
MAGNET WEIGHT
H*W*D
POWER REQUIREMENTS 400/480 V
COOLING SYSTEM TYPE Liquid helium
CRYOGEN USE
FIELD STRENGTH 1.0 T
STRENGTH 20 mT/m
5-GAUSS FRINGE FIELD
SHIMMING Passive/active
spacer

• View the DATABASE results for 'Panorama 1.0T™' (2).Open this link in a new window

MRI Resources 
Case Studies - MRI Technician and Technologist Jobs - Equipment - Contrast Agents - Absorption and Emission - IR
 
PoleStar™InfoSheet: - Devices -
Intro, 
Types of Magnets, 
Overview, 
etc.MRI Resource Directory:
 - Devices -
 
www.odinmed.com/site/content/system/benefits.asp From Odin Medical Technologies, Inc.;
the PoleStar™ N-10 is a compact, mobile MRI scanner that mounts to a standard operating room table. The magnets raise into position for imaging, but lower to make surgery easier, and the low magnetic field makes it possible to use many conventional surgical instruments.
When not in use, the PoleStar™ is stored in a nearby closet that allows the room to be used for conventional surgical procedures. The PoleStar™ N-10 is supplied with a fully integrated image guidance system that utilizes intraoperatively acquired images.
The successor, the new PoleStar™ N20 sets a new standard in intraoperative magnetic resonance imaging.
Device Information and Specification
CLINICAL APPLICATION Intraoperative
CONFIGURATION Semi-portable open MRI
MAGNET TYPE Permanent Magnet
MAGNET WEIGHT 500 kg
H*W*D 97x139x110 cm
FIELD STRENGTH 0.15 T
5-GAUSS FRINGE FIELD 1.5 m
spacer

• View the DATABASE results for 'PoleStar™' (2).Open this link in a new window

MRI Resources 
Journals - Veterinary MRI - Education - Cochlear Implant - Absorption and Emission - Resources
 
previous      46 - 50 (of 70)     next
Result Pages : [1 2 3 4 5 6 7 8 9 10 11 12 13 14]
 Random Page
 
Share This Page
FacebookTwitterLinkedIn

MR-TIP    
Community   
User
Pass
Forgot your UserID/Password ?  



In 2075 (after about 100 years of ...) the MRI scan will be :
obsolete 
done with handheld probe 
done at home (app, ...) 
a 3 second walk through 
daily done 
replaced by something much ... 

Look
      Ups





MR-TIP.com uses cookies! By browsing MR-TIP.com, you agree to our use of cookies.

Magnetic Resonance - Technology Information Portal
Member of SoftWays' Medical Imaging Group - MR-TIP • Radiology-TIP • US-TIP • The-Medical-Market
Copyright © 2003 - 2016 SoftWays. All rights reserved. [ 26 February 2017]
Terms of Use | Privacy Policy | Advertising
 [last update: 2017-02-21 00:45:00]