| AIRIS II™ |   |
| |
|
From Hitachi Medical Systems America Inc.;
the AIRIS II, an entry in the diagnostic category of open MR systems, was designed by Hitachi
Medical Systems America Inc. (Twinsburg, OH, USA) and Hitachi Medical Corp. (Tokyo) and is manufactured by the Tokyo branch. A 0.3 T field-strength magnet and phased array coils deliver high image quality without the need for a tunnel-type high-field system, thereby significantly improving patient comfort not only for claustrophobic patients.
|
|
Device Information and Specification |
| CLINICAL APPLICATION |
Whole body |
| CONFIGURATION |
Vertical Field, Open MRI |
| SURFACE COILS |
QD Head, MA Head and Neck, QD C-Spine, MA or QD Shoulder, MA CTL Spine, QD Knee, Neck, QD TMJ, QD Breast, QD Flex Body (4 sizes), Small and Large Extrem., QD Wrist, MA Foot and Ankle (WIP), PVA (WIP) |
| SPECTROSCOPY |
No |
| SYNCHRONIZATION |
Cardiac gating, ECG/peripheral, respiratory gating (2 modes) |
| PULSE SEQUENCES |
SE, GE, GR, IR, FIR, STIR, FSE, ss-FSE, FLAIR, EPI -DWI, SE-EPI, ms - EPI, SSP, MTC, SARGE, RSSG, TRSG, MRCP, Angiography: CE, 2D/3D TOF |
| IMAGING MODES |
Single, multislice, volume study |
| TR |
SE: 30 - 10,000msec GE: 20 - 10,000msec IR: 50 - 16,700msec FSE: 200 - 16,7000msec |
| TE |
SE : 10 - 250msec IR: 10 -250msec GE: 5 - 50 msec FSE: 15 - 2,000 |
| SINGLE/MULTI SLICE |
0.05 sec/image (256 x 256) |
| FOV |
5cm to 42 cm continuous |
| SLICE THICKNESS |
2D: 2 - 100 mm; 3D: 0.5 - 5 mm |
| DISPLAY MATRIX |
1280 x 1024 |
| MEASURING MATRIX |
512 x 512 |
| PIXEL INTENSITY |
Level Range: -2,000 to +4,000 |
| SPATIAL RESOLUTION |
Sub millimeter |
| MAGNET TYPE |
Self-shielded, permanent |
BORE DIAMETER or W x H |
110 x 43 cm |
| MAGNET WEIGHT |
15,700 kg |
| H*W*D |
79 x 111 x 73 cm |
| POWER REQUIREMENTS |
208/220/240 V, single phase |
| COOLING SYSTEM TYPE |
Air-cooled |
| CRYOGEN USE |
|
| FIELD STRENGTH |
0.3 T |
| STRENGTH |
15 mT/m |
| 5 GAUSS FRINGE FIELD |
2.0 m lateral, 2.5 m vert./long |
| SHIMMING |
Auto shimming, 3-axis/patient, and volume shim |
|
| |  | | | |
|  |
 |
MRI Resources |
|
| | | |  |  |  |
| ARTOSCAN™ - M |   |
| |
|
Developed by GE Lunar; the ARTOSCAN™-M is designed specifically for in-office musculoskeletal imaging. ARTOSCAN-M's compact, modular design allows placing within a clinical environment, bringing MRI to the patient. Patients remain outside the magnet at all times during the examinations, enabling constant patient-technologist contact. ARTOSCAN-M requires no special RF room, magnetic shielding, special power supply or air conditioning.
The C-SCAN™ (also known as Artoscan C) is developed from the ARTOSCAN™ - M, with a new computer platform.
|
|
Device Information and Specification |
| CLINICAL APPLICATION |
Dedicated extremity
|
| CONFIGURATION |
Closed |
| SURFACE COILS |
Linear and dual phased array coil, knee, ankle, wrist coils |
| PULSE SEQUENCES |
SE, GE, IR, STIR, FSE, 3D CE, GE-STIR, 3D GE, ME, TME, HSE |
| IMAGING MODES |
Single, multislice, volume study, fast scan, multi slab, cine |
| TR |
12 - 5,000 msec |
| TE |
5 - 220 msec |
| SINGLE SLICE |
0.8 sec/image |
| MULTISLICE |
0.8 sec/image |
| FOV |
10 - 20 cm |
| SLICE THICKNESS |
2D: 2 mm - 10 mm;
3D: 0.6 mm - 10 mm |
| DISPLAY MATRIX |
512 x 512 |
| MEASURING MATRIX |
256 x 256 maximum |
| PIXEL INTENSITY |
4,096 gray lvls, 256 lvls in 3D |
| SPATIAL RESOLUTION |
0.4 mm |
| MAGNET TYPE |
Ferrite Permanent |
| MAGNET WEIGHT |
965 kg |
| POWER REQUIREMENTS |
100/110/200/220/230/240 |
| FIELD STRENGTH |
0.2 T |
| STRENGTH |
10 mT/m |
| 5 GAUSS FRINGE FIELD, radial/axial |
28 cm/60 cm |
| SHIMMING |
Passive |
|
| |  | |
Further Reading: |
News & More:
|
| | |
|  |
 |
Searchterm 'Device Information'
was also found in the following service of MR-TIP.com: |
|
| | | |
|
 |  |
| Altaire™ |   |
| |
|
From Hitachi Medical Systems America, Inc.;
the AIRIS made its debut in 1995. Hitachi followed up with the AIRIS II system, which has proven equally successfully. 'All told, Hitachi has installed more than 1,000 MRI systems in the U.S., holding more than 17 percent of the total U.S. MRI installed base, and more than half of the installed base of open MR systems,' says Antonio Garcia, Frost & Sullivan industry research analyst.
Now Altaire employs a blend of innovative Hitachi features called VOSI™ technology, optimizing each sub-system’s performance in concert with the
other sub-systems, to give the seamless mix of high-field performance
and the patient comfort, especially for claustrophobic patients, of open MR systems.
|
|
Device Information and Specification |
| CLINICAL APPLICATION |
Whole body |
| CONFIGURATION |
Vertical Field, Open MRI |
| SURFACE COILS |
DualQuad T/R Body Coil, MA Head, MA C-Spine, MA Shoulder, MA Wrist, MA CTL Spine, MA Knee, MA TMJ, MA Flex Body (3 sizes), Neck, small and large Extremity, PVA (WIP), Breast (WIP), Neurovascular (WIP), Cardiac (WIP) and MA Foot//Ankle (WIP) |
| SPECTROSCOPY |
No |
| SYNCHRONIZATION |
Cardiac gating, ECG/peripheral, respiratory gating (2 modes) |
| PULSE SEQUENCES |
SE, GE, GR, IR, FIR, STIR, ss-FSE, FSE, DE-FSE/FIR, FLAIR, ss/ms-EPI, ss/ms EPI- DWI, SSP, MTC, SE/GE-EPI, MRCP, SARGE, RSSG, TRSG, BASG, Angiography: CE, PC, 2D/3D TOF |
| IMAGING MODES |
Single, multislice, volume study |
| TR |
SE: 30 - 10,000msec GE: 3.6 - 10,000msec IR: 50 - 16,700msec FSE: 200 - 16,7000msec |
| TE |
SE : 8 - 250msec IR: 5.2 -7,680msec GE: 1.8 - 2,000 msec FSE: 5.2 - 7,680 |
| SINGLE/MULTI SLICE |
0.05 sec/image (256 x 256) |
| FOV |
5cm to 45 cm continuous |
| SLICE THICKNESS |
2D: 2 - 100 mm; 3D: 0.5 - 5 mm |
| DISPLAY MATRIX |
1280 x 1024 |
| MEASURING MATRIX |
512 x 512 |
| PIXEL INTENSITY |
Level Range: -2,000 to +4,000 |
| SPATIAL RESOLUTION |
Sub millimeter |
| MAGNET TYPE |
Self-shielded, superconducting |
BORE DIAMETER or W x H |
115 x 47 cm |
| MAGNET WEIGHT |
41,700 kg |
| H*W*D |
256 x 348 x 236 cm |
| POWER REQUIREMENTS |
208 V +/- 10%, 3 phase |
| COOLING SYSTEM TYPE |
Water-cooled |
| CRYOGEN USE |
Refill 1/year |
| FIELD STRENGTH |
0.7 T |
| STRENGTH |
22 mT/m |
| 5 GAUSS FRINGE FIELD |
3.1 m lateral, 3.6 m vertical |
| SHIMMING |
Auto shimming, 3-axis/patient and active shimming |
|
| |  | |
Further Reading: |
News & More:
|
| | |
|  |
 |
MRI Resources |
|
| | | |  |  |  |
| Aurora® 1.5T Dedicated Breast MRI System |  |
| |
|
| From Aurora Imaging Technology, Inc.;
|
The Aurora® 1.5T Dedicated Breast MRI System with Bilateral SpiralRODEO™ is the first and only FDA approved MRI device designed specifically for breast imaging. The Aurora System, which is already in clinical use at a growing number of leading breast care centers in the US, Europe, got in December 2006 also the approval from the State Food and Drug Administration of the People's Republic of China (SFDA).
'Some of the proprietary and distinguishing features of the Aurora System include: 1) an ellipsoid magnetic shim that provides coverage of both breasts, the chest wall and bilateral axillary lymph nodes; 2) a precision gradient coil with the high linearity required for high resolution spiral reconstruction;; 3) a patient-handling table that provides patient comfort and procedural utility; 4) a fully integrated Interventional System for MRI guided biopsy and localization; and 5) the user-friendly AuroraCAD™ computer-aided image display system designed to improve the accuracy and efficiency of diagnostic interpretations.'
|
|
|
| |  | |
Further Reading: |
News & More:
|
| | | | •• There are 3 news about 'Aurora® 1.5T Dedicated Breast MRI System'. | |
|  |
 |
Searchterm 'Device Information'
was also found in the following service of MR-TIP.com: |
|
| | | |
|
 |  |
| C-SCAN™ |   |
| |
|
Manufactured by Esaote S.p.A.; compact in-office MRI system, fits in a 90 ft² (8.4 m²) space and requires no shielding or special power. This low field MRI magnet is optimized for orthopedic use and imaging of the extremities.
The C-SCAN™ is developed from the ARTOSCAN™ - M with a new computer platform, and is also known as Artoscan C.
Hologic Inc. is the exclusive U.S. distributor of this MRI device.
|
|
Device Information and Specification |
| CLINICAL APPLICATION |
Dedicated extremity
|
| CONFIGURATION |
Closed |
| SURFACE COILS |
Linear and dual phased array, knee, ankle, wrist (6 total) coils |
| PULSE SEQUENCES |
SE, GE, IR, STIR, FSE, 3D CE, GE-STIR, 3D GE, ME, TME, HSE |
| IMAGING MODES |
Single, multislice, volume study, fast scan, multi slab |
| TR |
12 - 5,000 msec |
| TE |
5 - 220 msec |
| SINGLE SLICE |
0.8 sec/image |
| MULTISLICE |
0.8 sec/image |
| FOV |
10 - 20 cm |
| SLICE THICKNESS |
2D: 2 mm - 10 mm;
3D: 0.6 mm - 10 mm |
| DISPLAY MATRIX |
512 x 512 |
| MEASURING MATRIX |
256 x 256 maximum |
| PIXEL INTENSITY |
4,096 gray lvls, 256 lvls in 3D |
| SPATIAL RESOLUTION |
0.4 mm |
| MAGNET TYPE |
Permanent |
BORE DIAMETER or W x H |
33.6 x 16 cm |
| MAGNET WEIGHT |
960 kg |
| H*W*D |
124 x 76 x 60 cm |
| POWER REQUIREMENTS |
100/110/200/220/230/240 |
| FIELD STRENGTH |
0.2 T |
| STRENGTH |
10 mT/m |
| 5-GAUSS FRINGE FIELD, radial/axial |
28 cm/60 cm |
| SHIMMING |
Passive |
|
| |  | |
Further Reading: |