Result : Searchterm 'Angiography' found in 14 terms [] and 98 definitions []
previous     6 - 10 (of 112)     next
Result Pages : [1 2 3]  [4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 ... ]
Searchterm 'Angiography' was also found in the following services: 
spacer
News  (19)  Resources  (26)  Forum  (6)  
 
Magnetic Resonance Angiography MRAMRI Resource Directory:
 - MRA -
 
(MRA) Magnetic resonance angiography is a medical imaging technique to visualize blood filled structures, including arteries, veins and the heart chambers. This MRI technique creates soft tissue contrast between blood vessels and surrounding tissues primarily created by flow, rather than displaying the vessel lumen. There are bright blood and black blood MRA techniques, named according to the appearance of the blood vessels. With this different MRA techniques both, the blood flow and the condition of the blood vessel walls can be seen. Flow effects in MRI can produce a range of artifacts. MRA takes advantage of these artifacts to create predictable image contrast due to the nature of flow.
Technical parameters of the MRA sequence greatly affect the sensitivity of the images to flow with different velocities or directions, turbulent flow and vessel size.
This are the three main types of MRA:
All angiographic techniques differentially enhance vascular MR signal. The names of the bright blood techniques TOF and PCA reflect the physical properties of flowing blood that were exploited to make the vessels appear bright. Contrast enhanced magnetic resonance angiography creates the angiographic effect by using an intravenously administered MR contrast agent to selectively shorten the T1 of blood and thereby cause the vessels to appear bright on T1 weighted images.
MRA images optimally display areas of constant blood flow-velocity, but there are many situations where the flow within a voxel has non-uniform speed or direction. In a diseased vessel these patterns are even more complex. Similar loss of streamline flow occurs at all vessel junctions and stenoses, and in regions of mural thrombosis. It results in a loss of signal, due to the loss of phase coherence between spins in the voxel.
This signal loss, usually only noticeable distal to a stenosis, used to be an obvious characteristic of MRA images. It is minimized by using small voxels and the shortest possible TE. Signal loss from disorganized flow is most noticeable in TOF imaging but also affects the PCA images.
Indications to perform a magnetic resonance angiography (MRA):
•
Detection of aneurysms and dissections
•
Evaluation of the vessel anatomy, including variants
•
Blockage by a blood clot or stenosis of the blood vessel caused by plaques (the buildup of fat and calcium deposits)

Conventional angiography or computerized tomography angiography (CT angiography) may be needed after MRA if a problem (such as an aneurysm) is present or if surgery is being considered.

See also Magnetic Resonance Imaging MRI.
 
Images, Movies, Sliders:
 CE-MRA of the Carotid Arteries Colored MIP  Open this link in a new window
    
SlidersSliders Overview

 CE MRA of the Aorta  Open this link in a new window
    
SlidersSliders Overview

 TOF-MRA Circle of Willis Inverted MIP  Open this link in a new window
    

 PCA-MRA 3D Brain Venography Colored MIP  Open this link in a new window
    

 Circle of Willis, Time of Flight, MIP  Open this link in a new window
    
SlidersSliders Overview

 
Radiology-tip.comradCT Angiography,  Angiogram
spacer
Medical-Ultrasound-Imaging.comVascular Ultrasound,  Intravascular Ultrasound
spacer
 
• Related Searches:
    • Circle of Willis
    • Cardiovascular Imaging
    • Partial Echo
    • Blood Pool Agents
    • Contrast Enhanced MRI
 
Further Reading:
  Basics:
Magnetic resonance angiography: current status and future directions
Wednesday, 9 March 2011   by www.jcmr-online.com    
MR–ANGIOGRAPHY(.pdf)
  News & More:
3-D-printed model of stenotic intracranial artery enables vessel-wall MRI standardization
Friday, 14 April 2017   by www.eurekalert.org    
Conventional MRI and MR Angiography of Stroke
2012   by www.mc.vanderbilt.edu    
MR Angiography Highly Accurate In Detecting Blocked Arteries
Thursday, 1 February 2007   by www.sciencedaily.com    
Searchterm 'Angiography' was also found in the following services: 
spacer
Radiology  (34) Open this link in a new windowUltrasound  (9) Open this link in a new window
Coronary Angiography with D-TaggingMRI Resource Directory:
 - Cardiovascular Imaging -
 
(MRI-CA) Coronary angiography with dobutamine stress tagging (MR images are taken after the heart has been stressed by using a medication called dobutamine). Investigational noninvasive imaging as a diagnostic tool for evaluating stenosis, anatomy and flow effects in coronary arteries with dobutamine stress.

For Ultrasound Imaging (USI) see Stress Echocardiogram at Medical-Ultrasound-Imaging.com.
spacer

• View the DATABASE results for 'Coronary Angiography with D-Tagging' (3).Open this link in a new window

MRI Resources 
Knee MRI - Used and Refurbished MRI Equipment - Absorption and Emission - Implant and Prosthesis pool - Education pool - Quality Advice
 
Inflow Magnetic Resonance AngiographyMRI Resource Directory:
 - MRA -
 
(I MRA) In MR imaging, inflowing non-saturated fluid gives a higher signal intensity than stationary tissue. This effect makes it especially useful for imaging of flowing blood. Other factors such as susceptibility and spin saturation, can affect the signal of the blood within the vessels. Furthermore turbulence is part of normal blood flow and can decrease signal intensity.

See also Time of Flight Angiography.
 
Images, Movies, Sliders:
 TOF-MRA Circle of Willis Inverted MIP  Open this link in a new window
    

 Circle of Willis, Time of Flight, MIP  Open this link in a new window
    
SlidersSliders Overview

 
spacer
Searchterm 'Angiography' was also found in the following services: 
spacer
News  (19)  Resources  (26)  Forum  (6)  
 
Moving Bed Magnetic Resonance AngiographyMRI Resource Directory:
 - MRA -
 
For a contrast enhanced MR angiography of the peripheral blood vessels, the patient reclines on a moveable table that moves under the MR machine to provide images of the abdomen, upper and lower legs in one procedure. A time optimized 3D gradient echo protocol with contrast agent and tabletop movement in several stages is used.
spacer
Searchterm 'Angiography' was also found in the following services: 
spacer
Radiology  (34) Open this link in a new windowUltrasound  (9) Open this link in a new window
Contrast Enhanced Timing Robust Angiography
 
(CENTRA) A special form of k-space acquisition especially for contrast enhanced MRA. Longer scan times for high image resolution is possible, without a venous overlay, because the vast majority of contrast information is acquired only in the first seconds, the remaining scan time is used for resolution.
 
Images, Movies, Sliders:
 CE-MRA of the Carotid Arteries  Open this link in a new window
    
SlidersSliders Overview

 
spacer
MRI Resources 
Used and Refurbished MRI Equipment - Sequences - Homepages - Open Directory Project - Software - Nerve Stimulator
 
previous      6 - 10 (of 112)     next
Result Pages : [1 2 3]  [4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 ... ]
 Random Page
 
Share This Page
FacebookTwitterLinkedIn

MR-TIP    
Community   
User
Pass
Forgot your UserID/Password ?    



New acceleration techniques will :
reduce scan times 
cause artifacts 
increase expenses 
be useful if you have a lot of experience 
doesn't do much 
never heard of 

Look
      Ups





MR-TIP.com uses cookies! By browsing MR-TIP.com, you agree to our use of cookies.

Magnetic Resonance - Technology Information Portal
Member of SoftWays' Medical Imaging Group - MR-TIP • Radiology-TIP • Medical-Ultrasound-Imaging • 
Copyright © 2003 - 2024 SoftWays. All rights reserved. [ 19 April 2024]
Terms of Use | Privacy Policy | Advertising
 [last update: 2024-02-26 03:41:00]