Magnetic Resonance - Technology Information Portal Welcome to MRI Technology
Info
  Sheets

Out-
      side
 



 
 'Abdominal Imaging' 
SEARCH FOR    
 
  2 3 5 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Result : Searchterm 'Abdominal Imaging' found in 1 term [] and 10 definitions [], (+ 8 Boolean[] results
previous     11 - 15 (of 19)     next
Result Pages : [1]  [2 3]  [4]
Searchterm 'Abdominal Imaging' was also found in the following services: 
spacer
News  (3)  Resources  (3)  
 
Ultrashort Turbo Spin EchoInfoSheet: - Sequences - 
Intro, 
Overview, 
Types of, 
etc.MRI Resource Directory:
 - Sequences -
 
(UTSE) The ultrashort turbo spin echo (TSE / FSE) sequence is a technique with extremely short echo spacing, resulting in shorter scan times. This is an advantage in areas where motion is a problem, for example dynamic or abdominal imaging. The shorter scan time and echo spacing are achieved by using a higher TSE factor and an increased data sampling rate.
Disadvantages are the decrease in SNR (caused through the increase of the bandwidth) and artifacts if minimum echo spacing is used (incomplete dephasing of the 180° pulse FID).

See also Fast Spin Echo.
spacer
 
Further Reading:
  News & More:
Ultrashort echo time (UTE) MRI of the spine in thalassaemia
February 2004   by bjr.birjournals.org    
MRI Resources 
Functional MRI - Implant and Prosthesis pool - Contrast Enhanced MRI - - Online Books - Anatomy
 
AMAG Pharmaceuticals, Inc.MRI Resource Directory:
 - Developers -
 
www.amagpharma.com The company changed its name from Advanced Magnetics, Inc. to AMAG Pharmaceuticals, Inc. in July 2007.
AMAG Pharmaceuticals, Inc., a biopharmaceutical company, developed and manufactured organ-specific diagnostic contrast agents that provide clearer images during magnetic resonance imaging (MRI) tests used to detect tumors and other abnormalities.
The company had two MRI related products on the market: Feridex I.V. (for the diagnosis of liver lesions) and GastroMARK (used for bowel and abdominal MR imaging). In November 2008, AMAG Pharmaceuticals, Inc. decided to discontinue the manufacturing of Feridex. The development of Combidex as a contrast agent for lymph disease has also been stopped.
The Company has now two commercial products: Feraheme® and GastroMARK®. Feraheme® is the trade name of Ferumoxytol (formerly Code 7228) and is indicated for the treatment of iron deficiency anemia. Feraheme® is also being developed as a diagnostic agent for vascular-enhanced magnetic resonance imaging (MRI) to assess peripheral arterial disease.

MRI Contrast Agents:
•
•
•
•
Contact Information
MAIL
AMAG Pharmaceuticals, Inc.
61 Mooney St.
Cambridge, MA 02138
USA
PHONE
+1-617-497-2070
FAX
+1-617-547-2445
spacer

• View the DATABASE results for 'AMAG Pharmaceuticals, Inc.' (10).Open this link in a new window


• View the NEWS results for 'AMAG Pharmaceuticals, Inc.' (7).Open this link in a new window.
 
Further Reading:
  Basics:
Advanced Magnetics, Inc. Announces Name Change to AMAG Pharmaceuticals, Inc.
Tuesday, 24 July 2007   by salesandmarketingnetwork.com    
Ferumoxytol
   by www.amagpharma.com    
AMAG Pharmaceuticals Inc. Q4 2008 Earnings Call Transcript
Friday, 27 February 2009   by seekingalpha.com    
  News & More:
The demise of Combidex - Sinerem
Wednesday, 24 March 2010   by www.wellsphere.com    
MRI Resources 
Stent - Sequences - Hospitals - Equipment - Databases - General
 
MAGNETOM Trioâ„¢ (TIM System)InfoSheet: - Devices -
Intro, 
Types of Magnets, 
Overview, 
etc.
 
www.medical.siemens.com/webapp/wcs/stores/servlet/ProductDisplay?storeId=10001&langId=-11&catalogId=-11&catTree=100001%2C12786%2C12754&level=0&productId=145739 From Siemens Medical Systems;
The Magnetom Trio™, a 3T whole body MRI system with Tim (total imaging matrix technology), targets clinical applications such as abdominal, cardiac, spine, whole body and orthopedics. TIM enables flexible coil combinations for high resolution imaging of large anatomical areas without the need to change coils.
Device Information and Specification
CLINICAL APPLICATION
Whole body
CONFIGURATION
Short bore
CP head, CP integrated body coil, neck matrix, breast array, 8-channel knee array, CP wrist, shoulder array, CP extremity
Yes/Mutli-nuclear MRS
PULSE SEQUENCES
SE, IR, 2D/3D TurboSE, Turbo IR, Dark-Fluid IR, True IR, 2D/3D MEDIC, 2D/3D GRE FLASH, 2D/3D GRE FISP, 2D/3D PSIF, 2D TurboFLASH, 3D MP-RAGE, 3D TurboFLASH, 2D/3D TOF angiography, MTC, TONE with 3D TOF MRA, GMR, LOTA
IMAGING MODES
Single, multislice, volume study, multi angle, multi oblique
SINGLE/MULTI SLICE
178 images/sec at 256 x 256 at 100% FOV
40 cm
Min 2D/3D: 0.1/0.05 mm
1024 x 1024 full screen display
MEASURING MATRIX
64 x 64 to 1024 x 1024
10 micrometer
60 cm
MAGNET WEIGHT
12000 kg
H*W*D
221 x 244 x 213 cm
POWER REQUIREMENTS
380/400/420/440/480 V
COOLING SYSTEM TYPE
Single cryogen, 2 stage refrig.
0.12 L/hr helium
STRENGTH
40 - 45 mT/m
200 mT/m/ms
5-GAUSS FRINGE FIELD
3.4 m / 5.9 m
Passive, act.; 1st order std./2nd opt.
spacer
Searchterm 'Abdominal Imaging' was also found in the following services: 
spacer
News  (3)  Resources  (3)  
 
MAGNETOM Symphonyâ„¢InfoSheet: - Devices -
Intro, 
Types of Magnets, 
Overview, 
etc.MRI Resource Directory:
 - Devices -
 
www.med.siemens.com/med/d/gg/mr/products/symphony1.html From Siemens Medical Systems;
with the introduction of this system, it is possible to perform contrast MR angiography for abdominal, thoracic and neck vessels from the origins to the circle of Willis. The system also has many newer features including functional imaging, spectroscopy, advanced body, ortho- and neuroimaging.
Device Information and Specification
CLINICAL APPLICATION
Whole body
CONFIGURATION
Compact
Yes/SVS or CSI opt.
SYNCHRONIZATION
ECG/peripheral, respiratory gating
PULSE SEQUENCES
GRE, IR, FIR, STIR, TrueIR/FISP, FSE, FLAIR, MT, SS-FSE, MT-SE, MTC, MSE, EPI, GMR, fat/water sat./exc.
IMAGING MODES
Single, multislice, volume study, multi angle, multi oblique
TR
2.4 msec std.; 2.0 opt.; 1.8 w/30 mT/m at 256matrix
TE
1.1 msec std.; 0.9 opt.; 0.78 w/30 mT/m at 256matrix
SINGLE/MULTI SLICE
178 images/sec at 256 x 256 at 100% FOV
0.5 cm - 50 cm
Min 2D/3D: 0.1/0.05 mm
1024 x 1024 full screen display
MEASURING MATRIX
64 x 64 to 1024 x 1024
PIXEL INTENSITY
21 micrometer in plane, 11 micrometer optional
60 cm
MAGNET WEIGHT
4050kg, 5500kg in operation
H*W*D
236 x 215 x 160 cm w/covers
POWER REQUIREMENTS
380/400/420/440/480 V
COOLING SYSTEM TYPE
Single cryogen, 2 stage refrig.
Liquid He
STRENGTH
20/35 mT/m standard, 30/52 opt.
5-GAUSS FRINGE FIELD
2.5 m / 4.0 m
Passive, act.; 1st order std./2nd opt.
spacer

• View the DATABASE results for 'MAGNETOM Symphony™' (2).Open this link in a new window

 
Further Reading:
  Basics:
Symphony Brochure(.pdf)
MRI Resources 
Cochlear Implant - Libraries - Most Wanted - Musculoskeletal and Joint MRI - Guidance - Non-English
 
Combination Oral Contrast AgentsInfoSheet: - Contrast Agents - 
Intro, Overview, 
Characteristics, 
Types of, 
etc.MRI Resource Directory:
 - Contrast Agents -
 
Biphasic oral contrast agents may produce either high or low signal intensities depending on the pulse sequence used, for example low signal intensity on T1 weighted MR images and high signal intensity on T2 weighted images. The combination of different oral contrast agents can generate a macroscopic cancellation of negative and positive magnetic susceptibility, thereby eliminating susceptibility artifacts.
Possible combinations are e.g., ferric ammonium citrate and corn oil, or ferrous sulfate emulsified with baby formula. Paramagnetic agents combined with oil emulsion may be used in MRI as positive abdominal contrast agents. The combination of diamagnetic barium sulfate and superparamagnetic iron oxide (SPIO) in one suspension may be a useful negative contrast agent.

See also Gastrointestinal Paramagnetic Contrast Agents, Gastrointestinal Superparamagnetic Contrast Agents, Gastrointestinal Diamagnetic Contrast Agents, Gastrointestinal Imaging.
spacer

• View the DATABASE results for 'Combination Oral Contrast Agents' (3).Open this link in a new window

 
Further Reading:
  Basics:
Usefulness of MR Imaging for Diseases of the Small Intestine: Comparison with CT
2000   by www.ncbi.nlm.nih.gov    
MRI Resources 
Open Directory Project - PACS - - Knee MRI - Fluorescence - Universities
 
previous      11 - 15 (of 19)     next
Result Pages : [1]  [2 3]  [4]
 Random Page
 
Share This Page
FacebookTwitterLinkedIn

MR-TIP    
Community   
User
Pass
Forgot your UserID/Password ?    



MRI is trending to low field magnets :
reduced costs will lead to this change 
AI will close the gap to high field 
only in remote areas 
is only temporary 
never 

Look
      Ups





MR-TIP.com uses cookies! By browsing MR-TIP.com, you agree to our use of cookies.

Magnetic Resonance - Technology Information Portal
Member of SoftWays' Medical Imaging Group - MR-TIP • Radiology-TIP • Medical-Ultrasound-Imaging • 
Copyright © 2003 - 2024 SoftWays. All rights reserved. [ 25 April 2024]
Terms of Use | Privacy Policy | Advertising
 [last update: 2024-02-26 03:41:00]